Genel bilgiler
product brand nameSITOP
product type designationPSU8200
product designationPower supply SITOP modular
type of current supply24 V/40 A
input
type of the power supply network1-phase ve 2-phase AC
phase number1
voltage curve at inputAC
supply voltage at ACAutomatic selection; startup starting from Ue ≥ 90/180 V
supply voltage120 V/230 V
input voltage 1 at AC85... 132 V
input voltage 2 at AC170... 264 V
at 50 Hz230 V
at 60 Hz120 V
line frequency50/60 Hz
line frequency45... 65 Hz
wide range inputYok
buffering time for rated value of the output current in the event of power failure minimum25 ms
operating condition of the mains bufferingVin = 230 V
at rated input voltage 120 V15 A
at rated input voltage 230 V9 A
current limitation of inrush current at 25 °C maximum50 A
I2t value maximum8 A²·s
fuse protection typeVar
fuse protection type in the feederRecommended miniature circuit breaker 1-phase operation: 16 A characteristic C; required 2-phase operation: circuit breaker 2-pole connected veya circuit breaker 3RV2421-4BA10 (120 V) veya 3RV2411-1JA10 (230 V)
output
voltage curve at outputControlled, isolated DC voltage
product function output voltage controlledVar
product function output voltage stabilizedVar
output voltage at DC rated value24 V
at output 1 at DC rated value24 V
at output 1 at DC24 V
output voltage adjustableVar; via potentiometer
adjustable output voltage24... 28 V; maks. 960 W
relative overall tolerance of the voltage3 %
on slow fluctuation of input voltage0,1 %
on slow fluctuation of ohm loading0,1 %
maximum100 mV
typical50 mV
maximum240 mV
typical220 mV
display version for normal operationGreen LED for 24 V OK; LED yellow for overload; LED red for short-circuit veya latching shutdown
type of signal at outputRelay contact (NO contact, rating 60 V DC/ 0,3 A) for "24 V OK"
behavior of the output voltage when switching onOvershoot of Vout yaklaşık 3 %
response delay maximum1,5 s
typical30 ms
rated value40 A
rated range0... 40 A; +60... +70 °C: Derating 3%/K
supplied active power typical960 W
on short-circuiting during the start-up typical120 A
at short-circuit during operation typical120 A
on short-circuiting during the start-up25 ms
at short-circuit during operation25 ms
on short-circuiting during the start-up typical60 A
bridging of equipmentYok
efficiency
efficiency in percent92 %
at rated output voltage for rated value of the output current typical82 W
during no-load operation maximum6,8 W
closed-loop control
relative control precision of the output voltage with rapid fluctuation of the input voltage by +/- 15% typical1 %
relative control precision of the output voltage load step of resistive load 50/100/50 % typical1,9 %
load step 50 to 100% typical2 ms
load step 100 to 50% typical2 ms
relative control precision of the output voltage at load step of resistive load 10/90/10 % typical3,8 %
load step 10 to 90% typical1 ms
load step 90 to 10% typical1 ms
maximum1 ms
protection and monitoring
design of the overvoltage protection< 32 V
property of the output short-circuit proofVar
design of short-circuit protectionAlternatively, constant current characteristic yaklaşık 41 A veya latching shutdown
typical41 A
in normal operation250% Iout rated up to 25 ms, 150% Iout rated up to 5 s/min
typical41 A
display version for overload and short circuitLED yellow for "overload", LED red for "latching shutdown" veya "short-circuit"
safety
galvanic isolation between input and outputVar
galvanic isolationOutput voltage: SELV, ES1 (IEC 62368-1), DVC As (IEC 61204-7)
operating resource protection classClass I
maximum0,1 mA
typical0,1 mA
protection class IPIP20
EMC
for emitted interferenceEN 55022 Class B
for mains harmonics limitation-
for interference immunityEN 61000-6-2
standards, specifications, approvals
CE markingVar
UL onayıVar; cULus-Listed (UL 508, CSA C22.2 Yok. 107,1), File E197259
UKCA markingVar
Regulatory Compliance Mark (RCM)Var
NEC Class 2Yok
BISVar; R-41183539
CB-certificateVar
MTBF at 40 °C838.156 h
standards, specifications, approvals hazardous environments
IECExVar; IECEx Ex ec nC IIC T3 Gc
ATEXVar; ATEX (EX) II 3G Ex ec nC IIC T3 Gc
ULhazloc approvalVar
UKEXVar
CCC for hazardous zone according to GB standardVar
FM registrationYok
standards, specifications, approvals marine classification
shipbuilding approvalYok
American Bureau of Shipping Europe Ltd. (ABS)Yok
French marine classification society (BV)Yok
Det Norske Veritas (DNV)Var
Lloyds Register of Shipping (LRS)Yok
standards, specifications, approvals Environmental Product Declaration
Environmental Product DeclarationVar
total2.152,1 kg
during manufacturing74,1 kg
during operation2.076,5 kg
after end of life0,62 kg
ambient conditions
during operation-25... +70 °C; with natural convection
during transport-40... +85 °C
during storage-40... +85 °C
environmental category according to IEC 60721Climate class 3K3, 5... 95% no condensation
connection method
type of electrical connectionscrew terminal
at inputL, N, PE: 1 screw terminal her biri for 0,2... 4 mm² single-core/finely stranded
at output+, -: 2 screw terminals her biri for 0,5... 10 mm²
for auxiliary contacts13, 14 (alarm signal): 1 screw terminal her biri for 0,14... 1,5 mm²
mechanical data
width × height × depth of the enclosure145 × 145 × 150 mm
installation width × mounting height150 mm × 225 mm
top40 mm
bottom40 mm
left0 mm
right0 mm
fastening methodSnaps onto DIN rail EN 60715 35x15
DIN-rail mountingVar
S7 rail mountingYok
wall mountingYok
housing can be lined upVar
net weight3,1 kg
accessories
electrical accessoriesBuffer module, redundancy module
mechanical accessoriesDevice identification label 20 mm × 7 mm, TI-grey 3RT2900-1SB20
additional information
other informationSpecifications rated input voltage ve ambient temperature +25 °C (unless otherwise specified)
Approvals Certificates
global warming potential [CO2 eq] / during manufacturing74,1 kg
global warming potential [CO2 eq] / during operation2076,5 kg
global warming potential [CO2 eq] / after end of life0,62 kg
global warming potential [CO2 eq] / total2152,1 kg