Genel bilgiler
product brand nameSITOP
product type designationPSU6200
product designationPower supply SITOP PSU6200
type of current supply12 V/12 A
input
type of the power supply network1-phase AC veya DC
phase number1
voltage curve at inputAC/DC
minimum rated value120 V
maximum rated value240 V
initial value85 V
full-scale value264 V
supply voltage at DC110... 240 V
input voltage at DC85... 275 V
at 50 Hz240 V
at 60 Hz120 V
line frequency50/60 Hz
line frequency47... 63 Hz
wide range inputVar
overvoltage overload capability300 V AC for 30 s
buffering time for rated value of the output current in the event of power failure minimum70 ms
operating condition of the mains bufferingVin = 240 V
at rated input voltage 120 V1,4 A
at rated input voltage 240 V0,8 A
current limitation of inrush current at 25 °C maximum6 A
fuse protection type5 A
fuse protection type in the feederCircuit breaker from 4 A characteristic C/6 A characteristic B to 10 A characteristic C veya circuit breaker 3RV2011-1EA10 (setting 4 A) veya 3RV2711-1ED10 (UL 489)
output
voltage curve at outputControlled, isolated DC voltage
product function output voltage controlledVar
product function output voltage stabilizedVar
number of outputs1
output voltage at DC rated value12 V
at output 1 at DC rated value12 V
at output 1 at DC12 V
output voltage adjustableVar; via potentiometer
adjustable output voltage12... 15,5 V; maks. 144 W (173 W up to 45°C)
relative overall tolerance of the voltage3 %
on slow fluctuation of input voltage0,1 %
on slow fluctuation of ohm loading0,1 %
maximum30 mV
typical20 mV
maximum30 mV
typical20 mV
display version for normal operationGreen LED for 24 V OK
type of signal at outputElectronic contact (NO contact, contact rating 30 V DC/0,1 A) for DC O.K. veya diagnostic interface
behavior of the output voltage when switching onOvershoot of Vout < 2 %
response delay maximum0,5 s
typical100 ms
rated value12 A
rated range0... 12 A; 14,4 A up to +45°C; +60... +70 °C: Derating 3%/K
supplied active power typical144 W
on short-circuiting during the start-up typical14,4 A
at short-circuit during operation typical14,4 A
parallel switching of outputscan be set with DIP switch
bridging of equipmentVar; switchable characteristic
number of parallel-switched equipment resources for increasing the power2
efficiency
efficiency in percent89,3 %
at rated output voltage for rated value of the output current typical17 W
during no-load operation maximum3 W
closed-loop control
relative control precision of the output voltage at load step of resistive load 10/90/10 % typical3 %
load step 10 to 90% typical2 ms
load step 90 to 10% typical2 ms
maximum3 ms
protection and monitoring
design of the overvoltage protection< 20 V
property of the output short-circuit proofVar
design of short-circuit protectionShutdown ve periodic restart attempts
typical14,4 A
in normal operationoverload capability 150 % Iout rated up to 5 s/min
safety
galvanic isolation between input and outputVar
galvanic isolationOutput voltage: SELV, ES1 (IEC 62368-1), DVC As (IEC 61204-7)
operating resource protection classClass I
maximum3,5 mA
protection class IPIP20
EMC
for emitted interferenceEN 55022 Class B
for mains harmonics limitationEN 61000-3-2
for interference immunityEN 61000-6-2
standards, specifications, approvals
CE markingVar
UL onayıVar; cULus-Listed (UL 508, CSA C22.2 Yok. 107,1), File E197259
UKCA markingVar
EAC approvalVar
Regulatory Compliance Mark (RCM)Var
NEC Class 2Yok
SEMI F47Var
BISVar; R-41188271
CB-certificateVar
standards, specifications, approvals hazardous environments
IECExYok
ATEXYok
ULhazloc approvalYok
FM registrationYok
standards, specifications, approvals marine classification
shipbuilding approvalVar
American Bureau of Shipping Europe Ltd. (ABS)Var
French marine classification society (BV)Yok
Det Norske Veritas (DNV)Var
Lloyds Register of Shipping (LRS)Yok
standards, specifications, approvals Environmental Product Declaration
Environmental Product DeclarationVar
total453,9 kg
during manufacturing23,1 kg
during operation430,1 kg
after end of life0,38 kg
ambient conditions
during operation-30... +70 °C; with natural convection a monotonically increasing start-up from -25 °C, safe start-up from -40 °C
during transport-40... +85 °C
during storage-40... +85 °C
environmental category according to IEC 60721Climate class 3K3, 5... 95% no condensation
connection method
type of electrical connectionpush-in terminals
at inputL1/+, L2/N/-, PE: push-in for 0,5... 4 mm² single-core/finely stranded
at output+1, +2, -1, -2, -3: push-in for 0,5... 2,5 mm²
for auxiliary contacts13, 14 (alarm signal): 1 push-in terminal her biri for 0,2... 1,5 mm²
mechanical data
width × height × depth of the enclosure45 × 135 × 125 mm
installation width × mounting height45 mm × 225 mm
top45 mm
bottom45 mm
left0 mm
right0 mm
fastening methodSnaps onto DIN rail EN 60715 35x7.5/15
DIN-rail mountingVar
S7 rail mountingYok
wall mountingYok
housing can be lined upVar
net weight0,9 kg
accessories
electrical accessoriesRedundancy module
mechanical accessoriesIdentification labels SIMATIC ET 200SP 6ES7193-6LF30-0AW0
further information internet links
identification linkVar; acc. to IEC 61406-1:2022
additional information
other informationSpecifications rated input voltage ve ambient temperature +25 °C (unless otherwise specified)
Approvals Certificates
global warming potential [CO2 eq] / during manufacturing23,1 kg
global warming potential [CO2 eq] / during operation430,1 kg
global warming potential [CO2 eq] / after end of life0,38 kg