product type designation
product brand nameSCALANCE
product type designationXP208G EEC
transfer rate
transfer rate10, 100, 1000 Mbit/s
interfaces / for communication / integrated
for network components or terminal equipment8; M12
number of 10/100/1000 Mbit/s M12-ports (X-coded)8
interfaces / other
for operator console1
for signaling contact1
for power supply2
for operator console5-pole M12 socket (A-coded)
for signaling contact5-pole M12 plug (B-coded)
for power supply4-pole M12 plug (L-coded)
C-PLUGVar
product function / device replacement with replacement of the storage mediumVar
at DC / rated value24 V
at DC / maximum0,1 A
supply voltage, current consumption, power loss
product component / connection for redundant voltage supplyVar
type of voltage / 1 / of the supply voltageDC
supply voltage / 1 / rated value24 V; XP-200EEC with EN 50155 supports the voltage range 16,8... 31,2 V DC
power loss [W] / 1 / rated value7,7 W
consumed current / 1 / at rated supply voltage / maximum0,32 A
supply voltage / 1 / voltage range19,2... 31,2
consumed current / 1 / maximum0,32 A
type of electrical connection / 1 / for power supply4-pole M12 plug (L-coded)
product component / 1 / fusing at power supply inputVar
fuse protection type / 1 / at input for supply voltage4 A / 60 V
ambient conditions
during operation-40... +70 °C
during storage-40... +85 °C
during transport-40... +85 °C
noteEEC variants with EN 50155 support for 10 minutes: +85 °C
at 25 °C / without condensation / during operation / maximum95 %
protection class IPIP65
design, dimensions and weights
designcompact
width200 mm
height200 mm
depth49 mm
net weight1,8 kg
product feature / conformal coatingVar
material / of the enclosureAluminum
fastening methodmodule rack mounting, back wall mounting
wall mountingVar
product features, product functions, product components / general
cascading in the case of a redundant ring / at reconfiguration time of <\~0.3\~s50
cascading in cases of star topologyany (depending only on signal propagation time)
QoS according to DSCPVar
Cut Through switching methodYok
Store & Forward switching methodVar
product functions / management, configuration, engineering
CLIVar
web-based managementVar
MIB supportVar
TRAPs via emailVar
configuration with STEP 7Var
RMONVar
SMTP serverYok
port mirroringVar
multiport mirroringVar
CoSVar
with IRT / PROFINET IO switchYok
PROFINET IO diagnosisVar
switch-managedVar
PROFINET conformity classB
network load class / according to PROFINETIII
telegram length / for Ethernet / maximum10240 bayt
TelnetVar
HTTPVar
HTTPSVar
TFTPVar
SFTPVar
BOOTPVar
GMRPVar
DCPVar
LLDPVar
EtherNet/IPVar
SNMP v1Var
SNMP v2Var
SNMP v3Var
IGMP (snooping/querier)Var
I&M0 - device-specific informationVar
I&M1 - higher level designation/location designationVar
product functions / diagnostics
port diagnosticsVar
statistics Packet SizeVar
statistics packet typeVar
error statisticsVar
SysLogVar
product functions / VLAN
VLAN - port basedVar
VLAN - protocol-basedYok
VLAN - IP-basedYok
number of VLANs / maximum257
number of VLANs - dynamic / maximum257
number of VLANs / at ring redundancy (HRP; MRP; standby link)257
product functions / DHCP
DHCP serverVar
DHCP clientVar
DHCP Option 82Var
DHCP Option 66Var
DHCP Option 67Var
product functions / redundancy
protocol / is supported / Media Redundancy Protocol (MRP)Var
media redundancy protocol (MRP) with redundancy managerVar
Media Redundancy Protocol Interconnection (MRP-I)Var; LC mode
of the PROFINET IO device / is supported / H-Sync forwardingVar
of the PROFINET IO device / is supported / PROFINET system redundancyVar
ring redundancyVar
high speed redundancy protocol (HRP) with redundancy managerVar
high speed redundancy protocol (HRP) with standby redundancyVar
redundancy procedure STPVar
redundancy procedure RSTPVar
redundancy procedure RSTP+Var
redundancy procedure MSTPVar
Parallel Redundancy Protocol (PRP)/operation in the PRP-networkVar
Parallel Redundancy Protocol (PRP)/Redundant Network Access (RNA)Yok
passive listeningVar
LACPVar
system modification during operation
product function / configuration in RUN via CiR/H-CiRVar
product functions / security
IEEE 802.1x (radius)Var
RADIUS clientVar
broadcast/multicast/unicast limiterVar
broadcast blockingVar
SSHVar
SSLVar
product functions / time
SICLOCK supportVar
NTP-clientVar
SNTP clientVar
NTPVar
SNTPVar
IEEE 1588 profile defaultVar
standards, specifications, approvals
CE markingVar
UKCA markingVar
cULus approvalVar
KC onayıVar
Regulatory Compliance Mark (RCM)Var
for EMC interference emissionEN 61000-6-4, EN 50121-4, EN 50121-3-2, EMV06 Class S0
for immunity to EMCEN 61000-6-2, EN 50121-4, EN 50121-3-2
for safety / from CSA and ULUL 62368-1 E115352, CSA C22.2 Yok. 62368-1
standards, specifications, approvals / other
railway application in accordance with EN 50155Var; OT4, ST1, H1, S2, C1, L4, PC2
fire protection in accordance with EN 45545-2Var; Class HL1 - HL3
RoHS conformityVar
standards, specifications, approvals / marine classification
certificate of suitability / shipbuilding approval / noteCertifications marked 'Yok' are currently under renewal.
American Bureau of Shipping Europe Ltd. (ABS)Yok
French marine classification society (BV)Yok
Chinese Classification Society (CCS)Yok
Det Norske Veritas (DNV)Yok
Korean Register of Shipping (KRS)Yok
Lloyds Register of Shipping (LRS)Yok
Nippon Kaiji Kyokai (NK)Yok
Polski Rejestr Statkow (PRS)Yok
Royal Institution of Naval Architects (RINA)Yok
standards, specifications, approvals / Environmental Product Declaration
Environmental Product DeclarationVar
product functions / general
MTBF45 a
reference temperature / for MTBF determination40 °C
warranty period5 a
product function / is supported / identification linkVar; acc. to IEC 61406-1:2022