Dimensions (W x L x H)75.9 mm x 82.5 mm x 124.3 mm
Grid dimension18.9
Type of mountingvia DIN rail
Max. number of modules10
Product weight288
Mounting positionVertical, Horizontal
Ambient temperature-5, 50
Note on ambient temperature-5 - 60°C for vertical installation
Storage temperature-20, 70
Relative air humidity95%, Non-condensing
Degree of protectionIP20
Corrosion resistance class CRC0 - No corrosion stress
Vibration resistanceTransport application test with severity level 1 to FN 942017-4 and EN 60068-2-6
Shock resistanceShock test with severity level 1 to FN 942017-5 and EN 60068-2-27
Protection against direct and indirect contactPELV
LABS (PWIS) conformityVDMA24364 zone III
CE mark (see declaration of conformity)To EU EMC Directive, In accordance with EU RoHS Directive
UKCA marking (see declaration of conformity)To UK RoHS instructions
KC markKC-EMV
ApprovalRCM, c UL us - Listed (Oil)
Certificate issuing authorityUL E239998
Note on materialsRoHS compliant
Material housingPA
Diagnostics via LEDForce mode, Module status, Network status, Network status, engineering port 1, Network status, engineering port 2, Network status EtherCAT®, Network status port 1, Network status port 2, Run, Power su
Operator controlsDIP switch for RUN/STOP, Rotary switch for address setting, Optional: Operator unit CDSB
IP address settingDHCP, Via CODESYS, Optional: via operator unit CDSB
Fieldbus interfaceEthernet
Field bus, protocolACD (Address Conflict Detection), DLR (Device Level Ring), EtherNet/IP, EtherNet/IP QoS, EtherNet/IP Quickconnect, SNMP
Fieldbus interface, functionBus connection incoming/outgoing
Field bus, connection type2x socket
Field bus, connection systemRJ45
Fieldbus interface, connection pattern00995789
Field bus, connection pattern8
Field bus interface, electrical isolationYes
Field bus interface, transmission rate100 Mbit/s
Fieldbus interface 2, typeEthernet
Fieldbus interface 2, protocolCoE, EoE, EtherCAT®, FoE
Fieldbus interface 2, functionBus connection continuing
Fieldbus interface 2, connection typeSocket
Fieldbus interface 2, connection technologyRJ45
Fieldbus interface 2, connection pattern00995789
Fieldbus interface 2, number of pins/wires8
Fieldbus interface 2, galvanic isolationYes
Fieldbus interface 2, transmission rate100 Mbit/s
Ethernet interface, connection type2x socket
Ethernet interface, protocolEasyIP, Modbus TCP, OPC-UA, TCP/IP
Ethernet interface, functionDiagnostics, Switch
Ethernet interface, connection systemRJ45
Ethernet interface, connection pattern00995789
Ethernet interface, number of pins/wires8
Ethernet interface, transmission rate10 Mbit/s, 100 Mbit/s
Max. address volume, inputs64
Fieldbus interface, max. address volume for inputs512
Max. address volume, outputs64
Fieldbus interface, max. address volume for outputs512
System parametersDiagnostic memory, Fail-safe response, System start
Module parametersChannel alarms for undervoltage, Process value representation of analogue modules
Configuration supportOperator unit CDSB, CODESYS V3
Additional functionsCODESYS V3
CPU dataDual core 766 MHz
storage mediumMicro SD <= 32 GB, USB memory stick <= 32 GB
Power supply, functionElectronic system and sensors
Power supply, connection typeTerminal strip
Power supply, note on connection type> 4 A and UL 2x terminal strip for power supply
power supply, connection systemSpring-loaded terminal
Power supply, connection pattern00995847
Power supply, number of pins/wires4
Nominal DC operating voltage, electronics/sensors24
Permissible voltage fluctuations for electronics/sensors±25%
Power supply, conductor diameter0.2, 1.5
Power supply, note on conductor diameter0.2 - 2.5 mm² for flexible conductors without wire ferrule
Max. power supply8
Intrinsic current consumption at nominal operating voltage for electronics/sensoTypically 150 mA
Power failure bridging20
Reverse polarity protection24 V sensor supply against 0 V sensor supply
USB-interfaceUSB 2.0
Programming softwareCODESYS provided by Festo
Program memory100 MB user program
Processing timeApprox. 200 µs/1 k instruction
Function modulesAnd others, Read CPX-E module diagnostics, CPX-E diagnostic status, Copy CPX-E diagnostic trace
Buffering time real-time clock3
Flag120 kB remanent data, CODESYS variable concept
Isolation channel - internal busYes