Cookie Notice

We use cookies on our website to provide you with a better experience. Cookies are used to improve site performance, personalize content, and analyze traffic.

Festo CPX-AP-A-12DI4DO-M8-4P

Photo may not represent actual item. Refer to name and product specs for all details.

Festo CPX-AP-A-12DI4DO-M8-4P

Digital input/output module

FestoMFR # CPX-AP-A-12DI4DO-M8-4PSKU # YLSIDLTUO3G58KR
Dimensions (W x L x H)50.1 mm x 107.3 mm x 57.5 mm
Grid dimension50.1
Type of mountingScrew-clamped
Product weight88
Mounting positionAny
Ambient temperature-20, 50
Share

About This Product

Festo CPX-AP-A-12DI4DO-M8-4P (Digital input/output module) is supplied genuine and fast by Yılsa Engineering. Get an instant quote for Festo CPX-AP-A-12DI4DO-M8-4P — price, stock availability and technical specifications.

Festo CPX-AP-A-12DI4DO-M8-4P

  • Genuine, certified Festo product
  • Fast sourcing through a worldwide supply network
  • Product selection and compatibility support from our technical team
  • Equivalent and alternative product suggestions
  • Quotation and lead time tailored to your request

Specifications

Dimensions (W x L x H)50.1 mm x 107.3 mm x 57.5 mm
Grid dimension50.1
Type of mountingScrew-clamped
Product weight88
Mounting positionAny
Ambient temperature-20, 50
Note on ambient temperatureObserve ambient temperature derating according to IEC 61131-2:2017
Storage temperature-20, 70
Relative air humidity5 - 95%, Non-condensing
Nominal altitude of use<= 2000 m ASL (> 79.5 kPa)
Max. installation height3500
Note on max. installation heightObserve ambient temperature derating according to IEC 61131-2:2017
Corrosion resistance class CRC1 - Low corrosion stress
Vibration resistanceTransport application test with severity level 2 to FN 942017-4 and EN 60068-2-6
Note on vibration resistanceSG1 on DIN rail, SG2 on direct mounting, Transport application test with severity class 1 to FN 942017-4 and EN 60068-2-6
Shock resistanceShock test with severity level 2 to FN 942017-5 and EN 60068-2-27
Note on shock resistance30 g/11 ms to EN 60068-2-27, SG1 on DIN rail, SG2 on direct mounting, Shock test with severity level 1 to FN 942017-5 and EN 60068-2-27
Protection classIII
Pollution degree2
Overvoltage categoryII
Max. cable length30 m outputs, 30 m inputs
LABS (PWIS) conformityVDMA24364-B2-L
Fire test materialUL94 V-0 (housing)
Note on materialsRoHS compliant, Free of halogen, Free of phosphoric acid ester
Material coverReinforced PBT
Material screwsNickel-plated steel
Material o-ringFluoro rubber
Diagnostics via LED(Outputs) Diagnostics per channel, Power supply load (outputs), (Inputs-Outputs) Diagnostics per module, (Inputs-Outputs) Status per channel
Diagnostics per internal communicationCommunication error, Short-circuit/overload in output signal, Short circuit/overload in sensor supply, Electronics/sensors overvoltage, Load overvoltage, Electronics/sensors undervoltage, Load undervo
Max. address volume, inputs2
Max. address volume, outputs1
Number of outputs4
Module parametersConfiguration of voltage monitoring load supply PL, Behaviour after short circuit/overload at the output
Channel parametersInput debounce time
Communication interface, protocolAP
Note regarding operating voltageSELV/PELV fixed power supplies required, Note the voltage drop
Note on nominal operating voltage DCProtected Extra-Low-Voltage to IEC 60204-1
Nominal operating voltage DC of load24
Permissible voltage fluctuation of load±25%
Nominal DC operating voltage, electronics/sensors24
Permissible voltage fluctuations for electronics/sensors±25%
Intrinsic current consumption at nominal operating voltage for electronics/sensoTypically 40 mA
Intrinsic current consumption at nominal operating voltage loadTypically 5 mA
Power failure bridging10
Potential separation between the supply voltages electronics/sensor technology aYes
Reverse polarity protectionYes
Electrical connection input, functionDigital input
Electrical connection input, connection type6x socket
Electrical connection input, connector systemM8x1, A-coded to EN 61076-2-104
Electrical connection input, number of connections/cores4
Electrical connection input, connection pattern00991872
Number of inputs12
Characteristic for inputsTo IEC 61131-2, type 3
Switching levelSignal 0: <= 5 V, Signal 1: ≥ 11 V
Switching logic for inputsPNP (positive switching), 2-wire sensors to IEC 61131-2, 3-wire sensors to IEC 61131-2
Input debounce time0.1 ms, 3 ms (standard), 10 ms, 20 ms
Behaviour after end of overload of the sensor supplyAutomatic return
Fuse protection of inputs (short circuit)Internal electronic fuse per module
Max. residual current of inputs per module1.8
Electrical isolation of inputs between channelsNo
Electrical isolation of inputs between channel – internal communicationYes
Electrical connection output, functionDigital output
Electrical connection output, connection type2x socket
Electrical connection output, connector systemM8x1, A-coded to EN 61076-2-104
Electrical connection output, number of connections/cores4
Electrical connection output, connection pattern00991872
Characteristic for outputsTo IEC 61131-2, type 0.5
Switching logic for outputsPNP (positive switching)
Fuse protection of outputs (short circuit)Internal electronic fuse per channel
Behaviour after end of overload of the outputsNo automatic return
Output delay with ohmic loadSignal change 0->1: < 200 µs, Signal change 1->0: < 200 µs
Max. residual current outputs per module2
Electrical isolation of outputs between channelsNo
Electrical isolation of outputs between channel - internal communicationYes
Max. power supply per channel0.5 A

Related Products

CPX-CTEL-2-M12-5POL-LK
Festo CPX-CTEL-2-M12-5POL-LK
View Details

Festo

CPX-CTEL-2-M12-5POL-LK

MFR #CPX-CTEL-2-M12-5POL-LK

SKU #YLSHKATQISCVYSQ

CPX-E
Festo CPX-E
View Details

Festo

CPX-E

MFR #CPX-E

SKU #YLS8TN5RGSLW1II

CPX-E-8DO
Festo CPX-E-8DO
View Details

Festo

CPX-E-8DO

MFR #CPX-E-8DO

SKU #YLSIQXEYRQRIHJ

CPX-E-4AI-U-I
Festo CPX-E-4AI-U-I
View Details

Festo

CPX-E-4AI-U-I

MFR #CPX-E-4AI-U-I

SKU #YLSV0SF0EXVLEKO

CPX-E-1CI
Festo CPX-E-1CI
View Details

Festo

CPX-E-1CI

MFR #CPX-E-1CI

SKU #YLST8BEMMPOFKWP

CPX-E-EC
Festo CPX-E-EC
View Details

Festo

CPX-E-EC

MFR #CPX-E-EC

SKU #YLSV3RDJNMQKFV

CPX-E-CEC-M1-EP
Festo CPX-E-CEC-M1-EP
View Details

Festo

CPX-E-CEC-M1-EP

MFR #CPX-E-CEC-M1-EP

SKU #YLSRZ5RSIQ5UFK

CPX-E-CEC-C1-EP
Festo CPX-E-CEC-C1-EP
View Details

Festo

CPX-E-CEC-C1-EP

MFR #CPX-E-CEC-C1-EP

SKU #YLS8UUREVRXTNOG

CPX-E-EP
Festo CPX-E-EP
View Details

Festo

CPX-E-EP

MFR #CPX-E-EP

SKU #YLSYZDT78JEQITU

CPX-E-PB
Festo CPX-E-PB
View Details

Festo

CPX-E-PB

MFR #CPX-E-PB

SKU #YLSUJEZBNPQNNRR

Featured Products

NCMC150-0600-X103US
SMC NCMC150-0600-X103US
View Details

SMC

NCMC150-0600-X103US

MFR #NCMC150-0600-X103US

SKU #YLS468HQT0B65QG

CDJ2L16-125Z-B
SMC CDJ2L16-125Z-B
View Details

SMC

CDJ2L16-125Z-B

MFR #CDJ2L16-125Z-B

SKU #YLS5V0RW2VJJR1A

MTS32-150M
SMC MTS32-150M
View Details

SMC

MTS32-150M

MFR #MTS32-150M

SKU #YLSSJCSBTRLX2P7

BC8M12
Brush Research Mfg BC8M12
View Details

Brush Research Mfg

BC8M12

MFR #BC8M12

SKU #YLSA0P5BE6ZJCIW

MXQ25-40B-M9NZ
SMC MXQ25-40B-M9NZ
View Details

SMC

MXQ25-40B-M9NZ

MFR #MXQ25-40B-M9NZ

SKU #YLST5TX9LNATRNS

NCDGFN25-0100
SMC NCDGFN25-0100
View Details

SMC

NCDGFN25-0100

MFR #NCDGFN25-0100

SKU #YLST0TDV975HLIN

SY5420-5DZ-01
SMC SY5420-5DZ-01
View Details

SMC

SY5420-5DZ-01

MFR #SY5420-5DZ-01

SKU #YLSQW9MERWL033X

VQZ2121-5LO1-N3T
SMC VQZ2121-5LO1-N3T
View Details

SMC

VQZ2121-5LO1-N3T

MFR #VQZ2121-5LO1-N3T

SKU #YLSEL35MGGQ9FOL

AW20-N02CG-6CZ-B
SMC AW20-N02CG-6CZ-B
View Details

SMC

AW20-N02CG-6CZ-B

MFR #AW20-N02CG-6CZ-B

SKU #YLSNOOF0IBCZ3J3

VQ1200-51-Q
SMC VQ1200-51-Q
View Details

SMC

VQ1200-51-Q

MFR #VQ1200-51-Q

SKU #YLSOVA6N31QD04G

Related Searches

Festo CPX-AP-A-12DI4DO-M8-4P priceFesto CPX-AP-A-12DI4DO-M8-4P quotebuy Festo CPX-AP-A-12DI4DO-M8-4PCPX-AP-A-12DI4DO-M8-4P priceCPX-AP-A-12DI4DO-M8-4P stock availabilityFesto spare partsFesto CPX-AP-A-12DI4DO-M8-4P equivalentFesto CPX-AP-A-12DI4DO-M8-4P specifications