Genel bilgiler
Ürün tipi tanımıDQ 4x24VDC/2A HF
FW update possibleVar
based on6ES7132-6BD21-0CA0
usable BaseUnitsBU type A0
Color code for module-specific color-coded labelCC02
Product function
I&M dataVar; I&M0 to I&M3
Isochronous modeVar
Mühendislik aracı
STEP 7 TIA Portal configurable/integrated from versionsee entry ID: 109746275
Operating mode
DQVar
DQ with energy-saving functionYok
PWMYok
OversamplingYok
MSOVar
Besleme gerilimi
Nominal değer (DC)24 V
İzin verilen aralık, alt sınır (DC)19,2 V
İzin verilen aralık, üst sınır (DC)28,8 V
Ters polarite korumasıVar
Giriş akımı
Akım tüketimi, maks.20 mA; without load
Çıkış gerilimi
Nominal değer (DC)24 V
Güç kaybı
Güç kaybı, tipik1 W
Address space per module
Address space per module, max.4 bayt; 2 channels per submodule + QI information
Donanım yapılandırması
Automatic encodingVar
Mechanical coding elementVar
Type of mechanical coding elementType A
Submodules
Number of configurable submodules, max.2
Selection of BaseUnit for connection variants
1-wire connectionBU type A0
2-wire connectionBU type A0
3-wire connectionBU type A0 with AUX terminals veya potential distributor module
Dijital çıkışlar
Type of digital outputSource output (PNP, current-sourcing)
Dijital çıkış sayısı4
Current-sinkingYok
Current-sourcingVar
Digital outputs, parameterizableVar
output type acc. to IEC 61131, type 2Var
Short-circuit protectionVar; Electronic
Response threshold, typ.2,8 to 5,2 A
Open-circuit detectionVar
Endüktif kapatma geriliminin sınırlandırılmasıTyp. L+ (-50 V)
Controlling a digital inputVar
Çıkışların anahtarlama kapasitesi
Omik yükte, maks.2 A
with inductive load, max.2 A
Lamba yükünde, maks.10 W
Load resistance range
lower limit12 Ω
upper limit3.400 Ω
Çıkış akımı
“1” sinyali için nominal değer2 A
for signal "1" permissible range, max.2 A
“0” sinyali için artık akım, maks.0,1 mA
Omik yükte çıkış gecikmesi
"0" to "1", typ.50 µs
"1" to "0", typ.100 µs
Parallel switching of two outputs
for upratingYok
for redundant control of a loadVar
Anahtarlama frekansı
Omik yükte, maks.100 Hz
with inductive load, max.0,1 Hz; higher frequencies are possible, see Equipment Manual "Maximum permitted switching frequency of inductive loads"
Lamba yükünde, maks.10 Hz
Total current of the outputs
Current per channel, max.2 A
Current per module, max.8 A; see Equipment Manual "Derating curve"
horizontal installation
— up to 30 °C, max.8 A
— 40 °C’ye kadar, maks.8 A
— up to 50 °C, max.6 A
— up to 60 °C, max.4 A
— up to 70 °C, max.2 A
vertical installation
— up to 30 °C, max.8 A
— 40 °C’ye kadar, maks.6 A
— up to 50 °C, max.4 A
Kablo uzunluğu
Ekranlı, maks.1.000 m
Ekransız, maks.600 m
Isochronous mode
Execution and activation time (TCO), min.75 µs
Bus cycle time (TDP), min.500 µs
Jitter, max.8 µs
Interrupts/diagnostics/status information
Diagnostics functionVar
Substitute values connectableVar
Alarms
Diagnostic alarmVar
Diagnoses
Monitoring the supply voltageVar
— ParametrelenebilirVar
Wire breakVar; channel by channel
Short-circuit to groundVar; channel by channel
Short-circuit to L+Var; channel by channel
Group errorVar
Tanılama gösterge LED’i
Monitoring of the supply voltage (PWR-LED)Var; green PWR LED
Channel status displayVar; green LED
for channel diagnosticsVar; red LED
for module diagnosticsVar; green/red DIAG LED
Potential separation channels
Kanallar arasıYok
between the channels and backplane busVar
Between the channels and load voltage L+Yok
Isolation
Isolation tested with707 V DC (type test)
Standartlar, onaylar, sertifikalar
Suitable for safety functionsYok
Suitable for safety-related tripping of standard modulesVar; see FAQ Entry ID: 39198632
Highest safety class achievable for safety-related tripping of standard modules
Performance level according to ISO 13849-1PL d
Category according to ISO 13849-1Cat. 3
SIL acc. to IEC 62061SIL 2
Çalışma ortam sıcaklığı
Yatay montaj, min.-40 °C; = Tmin (incl. condensation/frost)
Yatay montaj, maks.70 °C; = Tmax; > +60 °C maks. toplam current 2 A
Dikey montaj, min.-40 °C; = Tmin
Dikey montaj, maks.50 °C; = Tmax
Deniz seviyesine göre çalışma yüksekliği
Installation altitude above sea level, max.5.000 m; restrictions for installation altitudes > 2.000 m, see ET 200SP system manual
Bağıl nem
With condensation, tested in accordance with IEC 60068-2-38, max.100 %; RH incl. condensation / frost (no commissioning in bedewed state), yatay installation
Coolants and lubricants
— Resistant to commercially available coolants and lubricantsVar; Incl. diesel ve oil droplets in the air
Use in stationary industrial systems
— to biologically active substances according to EN 60721-3-3Var; Class 3B2 mold, fungus ve dry rot spores (with the exception of fauna); Class 3B3 talep üzerine
— to chemically active substances according to EN 60721-3-3Var; Class 3C4 (RH < 75%) incl. salt spray acc. to EN 60068-2-52 (severity degree 3)
— to mechanically active substances according to EN 60721-3-3Var; Class 3S4 incl. sand, dust
— Against mechanical environmental conditions acc. to EN 60721-3-3Var; Class 3M8 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0//6AG1193-6AB00-0AA0)
Use on ships/at sea
— to biologically active substances according to EN 60721-3-6Var; Class 6B2 mold, fungal ve dry rot spores (excluding fauna)
— to chemically active substances according to EN 60721-3-6Var; Class 6C3 (RH < 75%) incl. salt spray acc. to EN 60068-2-52 (severity degree 3).
— to mechanically active substances according to EN 60721-3-6Var; Class 6S3 incl. sand, dust
— Against mechanical environmental conditions acc. to EN 60721-3-6Var; class 6M4 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0/6AG1193-6AB00-0AA0)
Usage in industrial process technology
— Against chemically active substances acc. to EN 60654-4Var; Class 3 (excluding trichlorethylene)
— Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04Var; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) ve level LB3 (oil)
Conformal coating
Coatings for printed circuit board assemblies acc. to EN 61086Var; Class 2 for high reliability
Protection against fouling acc. to EN 60664-3Var; Type 1 protection
Military testing according to MIL-I-46058C, Amendment 7Var; Discoloration of coating possible during service life
Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830AVar; Conformal coating, Class A
Ölçüler
Genişlik15 mm
Yükseklik73 mm
Derinlik58 mm
Ağırlık
Ağırlık, yaklaşık30 g