product brand nameSIRIUS
product categorySafety relay
product designationBasic starter kit
design of the productcomprises 3SK2112-2AA10 basic unit, SIRIUS Safety Basic TIA for download ve 3UF7941-0AA00-0 USB PC cable
suitability for use for monitoring of optoelectronic protective devices according to IEC 61496-1Var
monitoring of floating sensorsVar
monitoring of non-floating sensorsVar
position switch monitoringVar
EMERGENCY-OFF circuit monitoringVar
valve monitoringVar
opto-electronic protection device monitoringVar
magnetically operated switch monitoringVar
proximity switch monitoringVar
safety-related circuitsVar
General technical data
EMERGENCY STOP functionVar
protective door monitoringVar
protective door monitoring with tumblerVar
muting, 2 sensor-parallelVar
muting, 4 sensor-parallelVar
muting, 4 sensor-sequentialVar
monitoring parameterizableVar
evaluation: electro-sensitive protective equipmentVar
evaluation: selector switchVar
pressure-sensitive mat monitoringVar
evaluation: two-hand operator panelVar
evaluation: enabling switchVar
monitored start-upVar
two-hand control according to EN 574Var
configuration software requiredVar; Safety ES V1.0 ve üstü
number of function blocks typical50
insulation voltage rated value50 V
degree of pollution3
surge voltage resistance rated value800 V
of the enclosureIP20
of the terminalIP20
shock resistance15 g / 11 ms
vibration resistance according to IEC 60068-2-65... 500 Hz: 0,75 mm
operating frequency maximum2.000 1/h
reference code according to IEC 81346-2F
Substance Prohibitance (day/month/year)07/01/2006
SVHC substance nameLead CAS-Yok. 7439-92-1 Lead monoxide (lead oxide) CAS-Yok. 1317-36-8 2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-Yok. 71868-10-5 Melamine CAS-Yok. 108-78-1
Net Weight0,45 kg
product function suitable for AS-i Power24VYok
product function diagnostics with CTT2 deviceYok
Ambient conditions
installation altitude at height above sea level maximum4.000 m
during operation-25... +60 °C
during storage-40... +80 °C
during transport-40... +80 °C
relative humidity during operation10... 95 %
air pressure according to SN 3120590... 106 kPa
Electromagnetic compatibility
EMC emitted interference according to IEC 60947-1class A
due to burst according to IEC 61000-4-42 kV (power ports) / 1 kV (signal ports)
field-based interference according to IEC 61000-4-310 V/m
electrostatic discharge according to IEC 61000-4-24 kV contact discharge / 8 kV air discharge
Safety related data
diagnostics test interval by internal test function maximum1.000 s
stop category according to IEC 60204-10 / 1
IEC 62061
SIL Claim Limit (subsystem) according to EN 620613
according to IEC 62061SIL 3
according to IEC 620611E-8 1/h
ISO 13849
performance level (PL) according to EN ISO 13849-1e
category according to EN ISO 13849-14
according to ISO 13849-1PL e
IEC 61508
according to IEC 615083
PFDavg with low demand rate according to IEC 615081.5E-5
according to IEC 615081
for proof test interval or service life according to IEC 6150820 a
Electrical Safety
touch protection against electrical shockfinger-safe
Inputs/ Outputs
parameterizable inputsVar
parameterizable outputsVar
at the digital outputs short-circuit protectionVar
safety-related10
non-safety-related0
input delay time0... 150 ms
type of digital inputs according to IEC 60947-1Type 1
ingress aquisition time at digital input maximum60 ms
input delay time at digital input maximum150 ms
input voltage at digital input at DC rated value24 V
for signal <1> typical2,6 mA
safety-related 2-channel2
for testing contact-based sensors2
1-channel0
2-channel0
safety-related 2-channel2
non-safety-related1
design of the contactless switching element safety-relatedP potential
recovery time of the safe outputs0 ms
readback time maximum400 ms
light test period3 ms
dark period of the common drivers3 ms
switching capacity current of semiconductor outputs at DC-13 at 24 V4 A
maximum0,1 mA
at digital output with signal <0> maximum0,1 mA
total current maximum6,5 A
voltage drop maximum0,5 V
— shielded maximum1.000 m
— unshielded maximum600 m
— shielded maximum1.000 m
— unshielded maximum600 m
Communication/ Protocol
PROFIBUS DP protocolVar; when using the DP interface module; 64 bit cyclical data
PROFINET IO protocolVar; when using the PN interface module; 64-bit cyclic data
protocol is supported AS-Interface protocolYok
Control circuit/ Control
type of voltageDC
control supply voltage rated value24 V
initial value0,85
full-scale value1,2
at 24 V10 A
at 24 V1 ms
operating power rated value2,5 W
Installation/ mounting/ dimensions
mounting positionany
fastening methodSnap-mounted to DIN rail veya screw-mounted with additional push-in lug
height100 mm
width22,5 mm
depth124,5 mm
Connections/ Terminals
product function removable terminalVar
type of electrical connectionspring-loaded terminal (push-in)
solid1x (0,5... 1,5 mm²), 2x (0,5... 1,5 mm²)
finely stranded with core end processing1x (0,5... 1,0 mm²), 2x (0,5... 1,0 mm²)
for AWG cables solid1x (20... 16), 2x (20... 16)
for AWG cables stranded1x (20... 16), 2x (20... 16)
connectable conductor cross-section finely stranded with core end processing0,5... 1 mm²
solid20... 16
stranded20... 16
Ürün bilgileri
EAN4047621095400
Ürün ailesiSIRIUS 3SK2 basic units
Yaşam döngüsü durumuAktif
Gümrük tarife kodu85371098
Teslimat ve lojistik
Menşe ülkeGermany
Teslim süresi5 gün
İade edilebilirEvet
Net ağırlık0,45 Kg
Paket ölçüleri (U x G x Y)315 x 186 x 158 MM
Standart paket adedi1 adet
Minimum sipariş adedi1
Tehlikeli maddeHayır
İhracat kontrolüAL : N / ECCN : 9N9999
Çevre ve uyumluluk
RoHS uyumuSince: 01-07-06
WEEE kategorisi5
REACH bilgisiLead CAS-No. 7439-92-1 > 0,1 % (w / w)
SCIP numarasıbcf9ae65-c457-4eab-903f-238e44a05cd2
Siemens kataloğu
Ürün grubu3761
Katalog kimliğiCC-IC10
Grup koduR711
Ürün sınıfıStraightforward, can be reused over the short term