product brand nameSIMATIC
product categoryMotor starter
product designationReversing starter
product type designationET 200SP
General technical data
equipment version according to IEC 60947-4-23
product functionFail-safe reversing starter
on-site operationVar
intrinsic device protectionVar
remote firmware updateVar
for power supply reverse polarity protectionVar
at AC in hot operating state per pole3 W
insulation voltage rated value500 V
degree of pollution2
overvoltage categoryIII
surge voltage resistance rated value6 kV
between main and auxiliary circuit500 V
consumed current maximum180 mA
shock resistance6 g / 11 ms
vibration resistance15 mm to 6 Hz; 2 g to 500 Hz
operating frequency maximum1 1/s
mechanical service life (operating cycles) of the main contacts typical30.000.000
type of coordination1
according to IEC 60947-4-2AC-53a: 12 A: (8-0,5: 72-32)
reference code according to IEC 81346-2Q
Substance Prohibitance (day/month/year)04/15/2016
SVHC substance nameLead CAS-Yok. 7439-92-1 Lead monoxide (lead oxide) CAS-Yok. 1317-36-8 6,6'-di-tert-butyl-2,2'-methylenedi-p-cresol CAS-Yok. 119-47-1
Net Weight0,462 kg
direct startVar
reverse startingVar
product component motor brake outputYok
product function short circuit protectionVar
design of short-circuit protectionfuse
at 400 V rated value55 kA
at 500 V rated value55 kA
at 500 V according to UL 60947 rated value100 kA
at 400 V rated value55 kA
at 500 V rated value55 kA
Electromagnetic compatibility
EMC emitted interference according to IEC 60947-1class A
EMC immunity according to IEC 60947-1Class A
due to burst according to IEC 61000-4-43 kV
due to conductor-earth surge according to IEC 61000-4-54 kV
due to conductor-conductor surge according to IEC 61000-4-52 kV
due to high-frequency radiation according to IEC 61000-4-6Class A
field-based interference according to IEC 61000-4-320 V/m
electrostatic discharge according to IEC 61000-4-28 kV air discharge
conducted HF interference emissions according to CISPR11Class A for industrial environment
field-bound HF interference emission according to CISPR11Class A for industrial environment
Safety related data
product function suitable for safety functionVar
safety-related switching onYok
safety-related switching OFFVar
safe stateLoad circuit open
test wear-related service life necessaryVar
function test interval maximum0,083 a
diagnostics test interval by internal test function maximum600 s
stop category according to IEC 60204-10
proportion of dangerous failures with high demand rate according to SN 3192050 %
B10 value with high demand rate according to SN 319201.000.000
IEC 62061
Safety Integrity Level (SIL) according to IEC 62061SIL 3
ISO 13849
performance level (PL) according to ISO 13849-1PL e
category according to ISO 13849-14
device type according to ISO 13849-11
overdimensioning according to ISO 13849-2 necessaryYok
IEC 61508
Safety Integrity Level (SIL) according to IEC 61508SIL 3
safety device type according to IEC 61508-2Type B
PFH according to IEC 61508 relating to SIL6E-9 1/h; for switching frequency 30/h
PFDavg with low demand rate according to IEC 615089E-7
Safe failure fraction (SFF)99,5 %
hardware fault tolerance according to IEC 615081
of service life according to IEC 6150820 a
Electrical Safety
touch protection against electrical shockfinger-safe
protection class IP on the front according to IEC 60529IP20
touch protection on the front according to IEC 60529finger-safe
ATEX
Safety Integrity Level (SIL) according to IEC 61508 relating to ATEXSIL 1
hardware fault tolerance according to IEC 61508 relating to ATEX1
Main circuit
number of poles for main current circuit3
design of the switching contactHybrid
adjustable current response value current of the current-dependent overload release4... 12 A
minimum load [%]50 %; from smallest adjustable rated current
type of the motor protectionsolid-state
operating voltage rated value48... 500 V
relative symmetrical tolerance of the operating voltage10 %
operating frequency 1 rated value50 Hz
operating frequency 2 rated value60 Hz
relative symmetrical tolerance of the operating frequency5 %
relative positive tolerance of the operating frequency5 %
relative negative tolerance of the operating frequency5 %
operational current at AC at 400 V rated value12 A
ampacity when starting maximum120 A
operating power for 3-phase motors at 400 V at 50 Hz2,2... 5,5 kW
Inputs/ Outputs
number of digital inputs5
note4 via 3DI/LC module
safety-related1
type of input characteristicType 1 in accordance with EN 61131-2
input voltage at digital input at DC rated value24 V
input current at digital input for signal <1> typical0 A
of the inputs4 bayt
of the outputs2 bayt
Besleme gerilimi
type of voltage of the supply voltageDC
minimum permissible20,4 V
maximum permissible28,8 V
supply voltage at DC rated value24 V
in standby mode of operation95 mA
during operation90 mA
at switching on of motor180 mA
in switching state OFF with bypass circuit2,2 W
in switching state ON with bypass circuit4,32 W
inrush current peak at 24 V25 A; Observe the manual for group configuration
duration of inrush current peak at 24 V0,14 ms
Response times
ON-delay time35 ms
OFF-delay time35... 50 ms
when switched off via control inputs maximum55 ms
when switched off via supply voltage maximum120 ms
Power Electronics
at 40 °C rated value12 A
at 50 °C rated value10 A
at 55 °C rated value9 A
at 60 °C rated value7 A
Installation/ mounting/ dimensions
mounting positionVertical, yatay (observe derating)
fastening methodpluggable in BaseUnit
height142 mm
width30 mm
depth150 mm
upwards50 mm
downwards50 mm
Ambient conditions
installation altitude at height above sea level maximum4.000 m
during operation-25... +60 °C; For derating see manual
during storage-40... +70 °C
during transport-40... +70 °C
environmental category during operation according to IEC 607213K6 (no formation of ice, no condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices)
relative humidity during operation10... 95 %
air pressure according to SN 31205900... 1.060 hPa
Communication/ Protocol
PROFIBUS DP protocolVar
PROFINET protocolVar
product function bus communicationVar
protocol is supported AS-Interface protocolYok
supports PROFIenergy measured valuesVar
supports PROFIenergy shutdownVar
type of electrical connection of the communication interfacePlug contact to Base Unit
Connections/ Terminals
1 for digital input signalsPluggable module - accessory
2 for digital input signalsPlug contact to Base Unit
for main energy infeedPlug contact to Base Unit
for load-side outgoing feederPlug contact to Base Unit
for supply voltage line-sidePlug contact to Base Unit
wire length for motor unshielded maximum200 m
UL/CSA ratings
full-load current (FLA) for 3-phase AC motor at 480 V rated value12 A
current with locked rotor (LRA) for 3-phase AC motor at 480 V rated value72 A
— at 110/120 V rated value0,5 hp
— at 230 V rated value2 hp
— at 200/208 V rated value2 hp
— at 220/230 V rated value3 hp
— at 460/480 V rated value7,5 hp
operating voltage at AC at 60 Hz according to CSA and UL rated value480 V