product type designation
product brand nameSCALANCE
product type designationXC424-4
transfer rate
transfer rate10, 100, 1000 Mbit/s
transfer rate10 Gbit/s
interfaces / for communication / integrated
for network components or terminal equipment24; RJ45 with securing collar
with securing collar24
for SFP+4; 1000 Mbps and 10000 Mbps SFP usable
interfaces / other
for operator console1
for signaling contact1
for power supply2
for operator consoleUSB (2.0 type B, USB-to-serial adapter)
for signaling contact2-pole terminal block
for power supply2 x 2-pole terminal block
CLPYes
at DC / rated value24 V
at DC / maximum0.1 A
supply voltage, current consumption, power loss
product component / connection for redundant voltage supplyYes
type of voltage supply / redundant power supply unitNo
type of voltage / 1 / of the supply voltageDC
supply voltage / 1 / rated value24 V
power loss [W] / 1 / rated value43.2 W
power loss [W] / at DC / at 24 V / typical25.92 W
supply voltage / 1 / voltage range19.2 ... 28.8
consumed current / 1 / maximum1.8 A
consumed current / at DC / at 24 V / typical1.08 A
type of electrical connection / 1 / for power supply2 x 2-pole terminal block
product component / 1 / fusing at power supply inputYes
fuse protection type / 1 / at input for supply voltageF 10 A / 250 V
ambient conditions
during operation-40 ... +60 °C
during storage-40 ... +85 °C
during transport-40 ... +85 °C
at 25 °C / without condensation / during operation / maximum95 %
operating condition / fanless operationYes
protection class IPIP20
design, dimensions and weights
designcompact
width210 mm
height147 mm
depth125 mm
net weight1.9 kg
19-inch installationNo
35 mm DIN-rail mountingYes
wall mountingYes
S7-300 rail mountingYes
S7-1500 rail mountingYes
product features, product functions, product components / general
cascading in the case of a redundant ring / at reconfiguration time of <\~0.3\~s50
number of automatically learnable MAC addresses16382
number of QoS queues / per port8
QoS according to IEEE 802.1QYes
Store & Forward switching methodYes
product functions / management, configuration, engineering
CLIYes
web-based managementYes
MIB supportYes
TRAPs via emailYes
configuration with STEP 7Yes
RMONYes
port mirroringYes
multiport mirroringYes
CoSYes
PROFINET IO diagnosisYes
switch-managedYes
PROFINET conformity classB
network load class / according to PROFINETIII
telegram length / for Ethernet / maximum9194 byte
TelnetYes
HTTPYes
HTTPSYes
TFTPYes
FTPYes
SFTPYes
BOOTPYes
NETCONFNo
GMRPYes
DCPYes
LLDPYes
EtherNet/IPYes
SNMP v1Yes
SNMP v2Yes
SNMP v3Yes
IGMP (snooping/querier)Yes
I&M0 - device-specific informationYes
I&M1 - higher level designation/location designationYes
product functions / diagnostics
port diagnosticsYes
statistics Packet SizeYes
statistics packet typeYes
error statisticsYes
SysLogYes
product functions / VLAN
VLAN - port basedYes
VLAN - protocol-basedNo
VLAN - IP-basedNo
VLAN dynamicYes
number of VLANs / maximum257
number of VLANs - dynamic / maximum257
number of VLANs / at ring redundancy (HRP; MRP; standby link)257
product function / VXLAN according to RFC 7348Yes
product functions / DHCP
DHCP serverYes
DHCP clientYes
DHCP Option 82Yes
DHCP Option 66Yes
DHCP Option 67Yes
product functions / routing
service / routing / noteIP routing integrated
static IP routingYes
static IP routing IPv6No
dynamic IP routingYes
dynamic IP routing IPv6No
RIPv2Yes
RIPnG for IPv6No
OSPFv2Yes
OSPFv3 for IPv6No
VRRPYes
VRRP for IPv6No
product functions / redundancy
protocol / is supported / Media Redundancy Protocol (MRP)Yes
media redundancy protocol (MRP) with redundancy managerYes
Media Redundancy Protocol Interconnection (MRP-I)Yes; LC mode
of the PROFINET IO device / is supported / PROFINET system redundancyYes
ring redundancyYes
high speed redundancy protocol (HRP) with redundancy managerYes
high speed redundancy protocol (HRP) with standby redundancyYes
redundancy procedure STPYes
redundancy procedure RSTPYes
redundancy procedure RSTP+Yes
redundancy procedure MSTPYes
High-availability Seamless Redundancy (HSR)Yes
Parallel Redundancy Protocol (PRP)/operation in the PRP-networkYes
Parallel Redundancy Protocol (PRP)/Redundant Network Access (RNA)Yes
passive listeningYes
STP/RSTPYes
STPYes
RSTPYes
MSTPYes
RSTP big network supportYes
LACPYes
system modification during operation
product function / configuration in RUN via CiR/H-CiRYes
product functions / security
IEEE 802.1x (radius)Yes
broadcast/multicast/unicast limiterYes
broadcast blockingYes
SSHYes
SSLYes
product functions / time
SICLOCK supportYes
NTP-clientYes
SNTP clientYes
IEEE 1588 v2 transparent forwardingYes
NTPYes
SNTPYes
not less than100 ns
typical50 ns
standards, specifications, approvals
CE markingYes
UKCA markingYes
KC approvalYes
Regulatory Compliance Mark (RCM)Yes
for EMC interference emissionEN 61000-6-4 (Class A)
for immunity to EMCEN 61000-6-2
for safety / from CSA and ULUL 60950-1; CSA C22.2 No. 213-M1987
standards, specifications, approvals / hazardous environments
CCC / for hazardous zone according to GB standardYes
standards, specifications, approvals / other
railway application in accordance with EN 50125-3Yes; Section 4.2: Class AX (up to 2000m); section 4.3: T1: Containers N.T.C and T.C. / Buildings N.C.C and C.C, T2: Containers N.T.C and T.C. / Buildings N.C.C and C.C, TX: Containers N.T.C and T.C. / Buildings N.C.C and C.C., derating according to the manual must be observed when SFP/SFP+ transceivers are used --> only for variants with optical connections; In addition, depending on the installation position, the derating according to the manual must be taken into account; section 4.4: T1: Containers C.C. / Buildings N.C.C and C.C., T2: Containers C.C. / Buildings N.C.C and C.C, T3: Containers C.C. / Buildings N.C.C and C.C; section 4.11: C1: Indoor, C2: Indoor (except condensation), C3: Indoor (except condensation), 4B1, 4S10, UL 61010-2-10; section 4.13: partially, Test Fc: Vibration EN 60068-2-6; IEC 60068-2-6, Test Ea: Shock EN 60068-2-27; IEC 60068-2-27, Test Ec: Rough handling, shocks EN 60068-2-31; IEC 60068-2-31; section 4.14: yes; section 4.15: yes, according to manual.
resistance to air pollution / conformity according to ANSI/ISA-71.04Yes; G3
IT security for industrial automation systems / according to IEC 62443-4-2:2019Yes
standards, specifications, approvals / Environmental Product Declaration
Environmental Product DeclarationYes
total1244.3 kg
during manufacturing122.74 kg
during operation1120.64 kg
after end of life0.91 kg
product functions / general
warranty period5 a
product function / is supported / identification linkYes; acc. to IEC 61406-1:2022
Approvals / Certificates
global warming potential [CO2 eq] / during manufacturing122.74 kg
global warming potential [CO2 eq] / during operation1120.64 kg
global warming potential [CO2 eq] / after end of life0.91 kg
global warming potential [CO2 eq] / total1244.3 kg