General information
Product type designationIM 155-6 MF HF
Firmware versionV6.4.1
FW update possibleYes
Vendor identification (VendorID)002AH
Device identifier (DeviceID)0313H
Manufacturer ID according to ODVA (VendorID)0x04E3
Device ID according to ODVA (Product code)0FA2H
based on6ES7155-6MU01-0CN0
Product function
I&M dataYes; I&M0 to I&M4
Module swapping during operation (hot swapping)Yes; Multi-hot swapping
Isochronous modeYes
IRTYes
Tool changerYes; Docking station and docking unit
Local coupling, IO dataYes
— Number of coupling modules6; 1x output + max. 5x input
Engineering with
STEP 7 TIA Portal configurable/integrated from versionsee entry ID: 109746275
PROFINET from GSD version/GSD revisionGSDML V2.45
Configuration control
via datasetYes
Supply voltage
Rated value (DC)24 V
permissible range, lower limit (DC)19.2 V
permissible range, upper limit (DC)28.8 V
Reverse polarity protectionYes
Short-circuit protectionYes
Mains buffering
Mains/voltage failure stored energy time10 ms
Input current
Current consumption (rated value)550 mA
Current consumption, max.650 mA
Inrush current, max.1 A
I²t0.05 A²·s
Power loss
Power loss, typ.2 W
Address space per module
Address space per module, max.288 byte; For input and output data respectively
Address space per station
Address space per station, max.1 440 byte
Rack
Quantity of operable ET 200SP modules, max.64
Submodules
Number of submodules per station, max.256
Interfaces
Transmission procedure100BASE-TX
Number of PROFINET interfaces1; 2 ports (switch)
Interface types
RJ 45 (Ethernet)Yes; with BusAdapter
Number of ports2; with BusAdapter
integrated switchYes
BusAdapter (PROFINET)Yes
Protocols
PROFINET IO DeviceYes
Open IE communicationYes
Media redundancyYes; PROFINET MRP client
Services
— IRTYes; 250 µs to 4 ms in 125 µs frame
— Dynamic Frame Packing (DFP)Yes
— PROFIenergyYes
— Prioritized startupYes
— Shared deviceYes
— Number of IO Controllers with shared device, max.14; 2x PN controller + 2x EtherNet/IP scanner + 10x Modbus TCP master
RJ 45 (Ethernet)
Transmission procedurePROFINET with 100 Mbit/s full duplex (100BASE-TX)
100 MbpsYes
AutonegotiationYes
AutocrossingYes
Protocols
Supports protocol for PROFINET IOYes
PROFIsafeYes
PROFIBUSNo
EtherNet/IPYes
Modbus TCPYes
Number of connections
Number of MtM communication relationships/connections, max.16
Redundancy mode
PROFINET system redundancy (S2)Yes; NAP S2
PROFINET system redundancy (R1)No
H-Sync forwardingYes
Media redundancy
— MRPYes
— MRPDYes
Services
— CIP Implicit MessagingYes
— CIP Explicit MessagingYes
— CIP SafetyNo
— Configuration control via Explicit MessagingNo
— Shared deviceYes; 2x PN controller + 2x EtherNet/IP scanner + 10x Modbus TCP master
— Number of scanners with shared device, max.2
Updating times
— Requested Packet Interval (RPI)2 ms
Address area
— Address space per module, max.288 byte; (246 byte outputs / 288 byte inputs)
— ForwardOpen (Class1 & 32 bit Header)500 byte; (246 byte outputs / 500 byte inputs)
— LargeForwardOpen (Class3)4 002 byte
Connections
— Number of rack connections2
Services
— read coils (code=1)Yes
— read discrete inputs (code=2)Yes
— Read Holding Registers (Code=3)Yes
— write single coil (code=5)Yes
— write multiple coils (code=15)Yes
— Write Multiple Registers (Code=16)Yes
— Parameter change by masterYes
— Modbus TCP Security ProtocolNo
Address space per station
— Address space per station, max.500 byte; (246 byte outputs / 500 byte inputs)
— Access-consistent address space250 byte; (246 byte outputs / 250 byte inputs)
Updating time
— I/O request interval2 ms
Connections
— number of connections per device9; (1x inputs / 2x outputs / 4x volatile registers / 2x Device Info)
Open IE communication
TCP/IPYes
UDPYes
SNMPYes
LLDPYes
ARPYes
IGMPYes
MulticastYes
BroadcastYes
IPv4Yes
IPv6No
Isochronous mode
EquidistanceYes
shortest clock pulse250 µs
max. cycle4 ms
Bus cycle time (TDP), min.250 µs
Jitter, max.1 µs
Interrupts/diagnostics/status information
Status indicatorYes
AlarmsYes
Diagnostics functionYes
Diagnostics indication LED
RUN LEDYes; green LED
ERROR LEDYes; red LED
MAINT LEDYes; Yellow LED
Monitoring of the supply voltage (PWR-LED)Yes; green PWR LED
NS LEDYes; green/red LED
MS LEDYes; green/red LED
IO LEDYes; red-green-yellow LED
Connection display LINK TX/RXYes; 2x green link LEDs on BusAdapter
Potential separation
between backplane bus and electronicsNo
between PROFINET and all other circuitsYes; 1500 V AC (type test)
between supply and all other circuitsNo
Permissible potential difference
between different circuitsSafety extra low voltage SELV
Isolation
Isolation tested with707 V DC (type test)
Standards, approvals, certificates
Network loading class3
Security
PROFINET Security Class1
signed firmware updateYes
Secure BootNo
securely removing dataYes
data integrityYes
Ambient temperature during operation
horizontal installation, min.-40 °C; = Tmin (incl. condensation/frost)
horizontal installation, max.60 °C; = Tmax
vertical installation, min.-40 °C; = Tmin
vertical installation, max.50 °C; = Tmax
Altitude during operation relating to sea level
Installation altitude above sea level, max.5 000 m; restrictions for installation altitudes > 2 000 m, see ET 200SP system manual
Relative humidity
With condensation, tested in accordance with IEC 60068-2-38, max.100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation
Coolants and lubricants
— Resistant to commercially available coolants and lubricantsYes; Incl. diesel and oil droplets in the air
Use in stationary industrial systems
— to biologically active substances according to EN 60721-3-3Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request
— to chemically active substances according to EN 60721-3-3Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
— to mechanically active substances according to EN 60721-3-3Yes; Class 3S4 incl. sand, dust, *
— Against mechanical environmental conditions acc. to EN 60721-3-3Yes; Class 3M8 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0//6AG1193-6AB00-0AA0)
Use on ships/at sea
— to biologically active substances according to EN 60721-3-6Yes; Class 6B2 mold, fungal and dry rot spores (excluding fauna)
— to chemically active substances according to EN 60721-3-6Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
— to mechanically active substances according to EN 60721-3-6Yes; Class 6S3 incl. sand, dust; *
— Against mechanical environmental conditions acc. to EN 60721-3-6Yes; class 6M4 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0/6AG1193-6AB00-0AA0)
Usage in industrial process technology
— Against chemically active substances acc. to EN 60654-4Yes; Class 3 (excluding trichlorethylene)
— Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)
Remark
— Note regarding classification of environmental conditions acc. to EN 60721, EN 60654-4 and ANSI/ISA-71.04* The supplied plug covers must remain in place over the unused interfaces during operation!
Conformal coating
Coatings for printed circuit board assemblies acc. to EN 61086Yes; Class 2 for high reliability
Protection against fouling acc. to EN 60664-3Yes; Type 1 protection
Military testing according to MIL-I-46058C, Amendment 7Yes; Discoloration of coating possible during service life
Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830AYes; Conformal coating, Class A
ET-Connection
via BU/BA SendYes; + 16 ET 200AL modules
Mechanics/material
Strain reliefYes; Optional
Dimensions
Width50 mm
Height117 mm
Depth74 mm
Weights
Weight, approx.120 g; without BusAdapter