Cookie Notice

We use cookies on our website to provide you with a better experience. Cookies are used to improve site performance, personalize content, and analyze traffic.

Siemens 6AG1134-6JF00-2CA1

Photo may not represent actual item. Refer to name and product specs for all details.

Siemens 6AG1134-6JF00-2CA1

SIPLUS ET 200SP AI 8xRTD/TC 2-wire based on 6ES7134-6JF00-0CA1 with conformal coating, -40…+60 °C, analog input module, suitable for BU type A0, A1, color code CC00, channel diagnostics, 16-bit, +/-0.1%

SiemensMFR # 6AG1134-6JF00-2CA1SKU # CEY-8EF3B0388330
Product type designationAI 8xRTD/TC 2-wire HF
FW update possibleYes
based on6ES7134-6JF00-0CA1
usable BaseUnitsBU type A0, A1
I&M dataYes; I&M0 to I&M3
Isochronous modeNo
Share

About This Product

SIPLUS ET 200SP AI 8xRTD/TC 2-wire based on 6ES7134-6JF00-0CA1 with conformal coating, -40…+60 °C, analog input module, suitable for BU type A0, A1, color code CC00, channel diagnostics, 16-bit, +/-0.1%

Siemens 6AG1134-6JF00-2CA1

  • Genuine, certified Siemens product
  • Fast sourcing through a worldwide supply network
  • Product selection and compatibility support from our technical team
  • Equivalent and alternative product suggestions
  • Quotation and lead time tailored to your request

Specifications

General information
Product type designationAI 8xRTD/TC 2-wire HF
FW update possibleYes
based on6ES7134-6JF00-0CA1
usable BaseUnitsBU type A0, A1
Color code for module-specific color-coded labelCC00
Product function
I&M dataYes; I&M0 to I&M3
Isochronous modeNo
Measuring range scalableYes
Engineering with
STEP 7 TIA Portal configurable/integrated from versionsee entry ID: 109746275
Operating mode
OversamplingNo
MSINo
CiR - Configuration in RUN
Reparameterization possible in RUNYes
Calibration possible in RUNYes
Supply voltage
Rated value (DC)24 V
permissible range, lower limit (DC)19.2 V
permissible range, upper limit (DC)28.8 V
Reverse polarity protectionYes
Input current
Current consumption, max.35 mA
Power loss
Power loss, typ.0.75 W
Address space per module
Address space per module, max.16 byte; + 1 byte for QI information
Hardware configuration
Mechanical coding elementYes
Type of mechanical coding elementType A
Selection of BaseUnit for connection variants
2-wire connectionBU type A0, A1
Analog inputs
Number of analog inputs8
permissible input voltage for voltage input (destruction limit), max.30 V
Constant measurement current for resistance-type transmitter, typ.2 mA
Cycle time (all channels), min.Sum of the basic conversion times and additional processing times (depending on the parameterization of the active channels)
Technical unit for temperature measurement adjustableYes; °C/°F/K
Input ranges (rated values), voltages
-1 V to +1 VYes; 16 bit incl. sign
— Input resistance (-1 V to +1 V)1 MΩ
-250 mV to +250 mVYes; 16 bit incl. sign
— Input resistance (-250 mV to +250 mV)1 MΩ
-50 mV to +50 mVYes; 16 bit incl. sign
— Input resistance (-50 mV to +50 mV)1 MΩ
-80 mV to +80 mVYes; 16 bit incl. sign
— Input resistance (-80 mV to +80 mV)1 MΩ
Input ranges (rated values), thermocouples
type BYes; 16 bit incl. sign
— Input resistance (Type B)1 MΩ
Type CYes; 16 bit incl. sign
— Input resistance (Type C)1 MΩ
Type EYes; 16 bit incl. sign
— Input resistance (Type E)1 MΩ
Type JYes; 16 bit incl. sign
— Input resistance (type J)1 MΩ
Type KYes; 16 bit incl. sign
— Input resistance (Type K)1 MΩ
Type LYes; 16 bit incl. sign
— Input resistance (Type L)1 MΩ
Type NYes; 16 bit incl. sign
— Input resistance (Type N)1 MΩ
Type RYes; 16 bit incl. sign
— Input resistance (Type R)1 MΩ
Type SYes; 16 bit incl. sign
— Input resistance (Type S)1 MΩ
Type TYes; 16 bit incl. sign
— Input resistance (Type T)1 MΩ
Type UYes; 16 bit incl. sign
— Input resistance (Type U)1 MΩ
Type TXK/TXK(L) to GOSTYes; 16 bit incl. sign
— Input resistance (Type TXK/TXK(L) to GOST)1 MΩ
Input ranges (rated values), resistance thermometer
Ni 100Yes; 16 bit incl. sign
— Input resistance (Ni 100)1 MΩ
Ni 1000Yes; 16 bit incl. sign
— Input resistance (Ni 1000)1 MΩ
LG-Ni 1000Yes; 16 bit incl. sign
— Input resistance (LG-Ni 1000)1 MΩ
Ni 120Yes; 16 bit incl. sign
— Input resistance (Ni 120)1 MΩ
Ni 200Yes; 16 bit incl. sign
— Input resistance (Ni 200)1 MΩ
Ni 500Yes; 16 bit incl. sign
— Input resistance (Ni 500)1 MΩ
Pt 100Yes; 16 bit incl. sign
— Input resistance (Pt 100)1 MΩ
Pt 1000Yes; 16 bit incl. sign
— Input resistance (Pt 1000)1 MΩ
Pt 200Yes; 16 bit incl. sign
— Input resistance (Pt 200)1 MΩ
Pt 500Yes; 16 bit incl. sign
— Input resistance (Pt 500)1 MΩ
Input ranges (rated values), resistors
0 to 150 ohmsYes; 15 bit
— Input resistance (0 to 150 ohms)1 MΩ
0 to 300 ohmsYes; 15 bit
— Input resistance (0 to 300 ohms)1 MΩ
0 to 600 ohmsYes; 15 bit
— Input resistance (0 to 600 ohms)1 MΩ
0 to 3000 ohmsYes; 15 bit
— Input resistance (0 to 3000 ohms)1 MΩ
0 to 6000 ohmsYes; 15 bit
— Input resistance (0 to 6000 ohms)1 MΩ
PTCYes; 15 bit
— Input resistance (PTC)1 MΩ
Temperature compensation
— ParameterizableYes
— Reference channel of the moduleYes
— internal comparison pointYes; with BaseUnit type A1
— Reference channel of the groupYes
— Number of reference channel groups4; Group 0 to 3
— fixed reference temperatureYes
Cable length
shielded, max.200 m; 50 m with thermocouples
Analog value generation for the inputs
Measurement principleintegrating (Sigma-Delta)
Integration and conversion time/resolution per channel
Resolution with overrange (bit including sign), max.16 bit
Integration time, parameterizableYes
— additional processing time for wire-break check2 ms; In the ranges resistance thermometers, resistors and thermocouples
Interference voltage suppression for interference frequency f1 in Hz16.6 / 50 / 60 Hz
Conversion time (per channel)180 / 60 / 50 ms
Smoothing of measured values
Number of smoothing levels4; None; 4/8/16 times
parameterizableYes
Connection of signal encoders
for voltage measurementYes
for resistance measurement with two-wire connectionYes
for resistance measurement with three-wire connectionNo
for resistance measurement with four-wire connectionNo
Errors/accuracies
Linearity error (relative to input range), (+/-)0.01 %; ±0.1 % for resistance thermometers and resistance
Temperature error (relative to input range), (+/-)0.0009 %/K; ±0.005 % / K at thermocouple
Crosstalk between the inputs, min.-50 dB
Repeat accuracy in steady state at 25 °C (relative to input range), (+/-)0.05 %
Operational error limit in overall temperature range
Voltage, relative to input range, (+/-)0.2 %
Resistance, relative to input range, (+/-)0.2 %
Basic error limit (operational limit at 25 °C)
Voltage, relative to input range, (+/-)0.05 %
Resistance, relative to input range, (+/-)0.05 %
Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency
Series mode interference (peak value of interference < rated value of input range), min.70 dB
Common mode voltage, max.10 V
Common mode interference, min.90 dB
Interrupts/diagnostics/status information
Diagnostics functionYes
Alarms
Diagnostic alarmYes
Limit value alarmYes; two upper and two lower limit values in each case
Diagnoses
Monitoring the supply voltageYes
Wire breakYes; channel by channel
Group errorYes
Overflow/UnderflowYes; channel by channel
Diagnostics indication LED
Monitoring of the supply voltage (PWR-LED)Yes; green PWR LED
Channel status displayYes; green LED
for channel diagnosticsYes; red LED
for module diagnosticsYes; green/red DIAG LED
Potential separation channels
between the channelsNo
between the channels and backplane busYes
between the channels and the power supply of the electronicsYes
Permissible potential difference
between the inputs (UCM)10 V DC
Isolation
Isolation tested with707 V DC (type test)
Ambient temperature during operation
horizontal installation, min.-40 °C; = Tmin (incl. condensation/frost)
horizontal installation, max.60 °C; = Tmax; +70 °C with spacing modules (6AG1193-6BN00-7BA0) or configured slots to the left and right of the module
vertical installation, min.-40 °C; = Tmin (incl. condensation/frost)
vertical installation, max.50 °C; = Tmax
Altitude during operation relating to sea level
Installation altitude above sea level, max.5 000 m
Ambient air temperature-barometric pressure-altitudeTmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)
Relative humidity
With condensation, tested in accordance with IEC 60068-2-38, max.100 %; RH incl. condensation/frost (no commissioning under condensation conditions)
Coolants and lubricants
— Resistant to commercially available coolants and lubricantsYes; Incl. diesel and oil droplets in the air
Use in stationary industrial systems
— to biologically active substances according to EN 60721-3-3Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request
— to chemically active substances according to EN 60721-3-3Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
— to mechanically active substances according to EN 60721-3-3Yes; Class 3S4 incl. sand, dust, *
— Against mechanical environmental conditions acc. to EN 60721-3-3Yes; Class 3M8 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0)
Use on ships/at sea
— to biologically active substances according to EN 60721-3-6Yes; Class 6B2 mold and fungal spores (excluding fauna); Class 6B3 on request
— to chemically active substances according to EN 60721-3-6Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
— to mechanically active substances according to EN 60721-3-6Yes; Class 6S3 incl. sand, dust; *
— Against mechanical environmental conditions acc. to EN 60721-3-6Yes; Class 6M4 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0)
Usage in industrial process technology
— Against chemically active substances acc. to EN 60654-4Yes; Class 3 (excluding trichlorethylene)
— Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)
Remark
— Note regarding classification of environmental conditions acc. to EN 60721, EN 60654-4 and ANSI/ISA-71.04* The supplied plug covers must remain in place over the unused interfaces during operation!
Conformal coating
Coatings for printed circuit board assemblies acc. to EN 61086Yes; Class 2 for high reliability
Protection against fouling acc. to EN 60664-3Yes; Type 1 protection
Military testing according to MIL-I-46058C, Amendment 7Yes; Discoloration of coating possible during service life
Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830AYes; Conformal coating, Class A
Dimensions
Width15 mm
Height73 mm
Depth58 mm
Weights
Weight, approx.32 g

Accessories 16

Genuine accessories that can be used with the Siemens 6AG1134-6JF00-2CA1 motor and are supplied separately are listed below. Click a code to open the accessory page and see the other compatible motors.

Part noDescriptionCompatible motors
6ES7193-6BP40-0DA1Aksesuar · BaseUnit
6ES7193-6BP40-0BA1Aksesuar · BaseUnit
6ES7193-6BP20-0DA0Aksesuar · BaseUnit
6ES7193-6BP20-0BA0Aksesuar · BaseUnit
6ES7193-6BP00-0DA1Aksesuar · BaseUnit
6ES7193-6BP00-0DA0Aksesuar · BaseUnit
6ES7193-6BP00-0BA1Aksesuar · BaseUnit
6ES7193-6BP00-0BA0Aksesuar · BaseUnit
6AG1193-6BP40-7DA1Zorunlu ek ürün · BaseUnit
6AG1193-6BP40-7BA1Zorunlu ek ürün · BaseUnit
6AG1193-6BP00-7DA1Zorunlu ek ürün · BaseUnit
6AG1193-6BP00-7BA1Zorunlu ek ürün · BaseUnit
6AG1193-6BP20-7DA0Zorunlu ek ürün · BaseUnit
6AG1193-6BP00-7DA0Zorunlu ek ürün · BaseUnit
6AG1193-6BP00-7BA0Zorunlu ek ürün · BaseUnit
6AG1193-6BP20-7BA0Zorunlu ek ürün · BaseUnit

Related Products

1FY2901-0EB00
Siemens 1FY2901-0EB00
View Details

Siemens

1FY2901-0EB00

MFR #1FY2901-0EB00

SKU #YLSJVRF7YVE9X

1FN3050-8SA00-0AA0
View Details

Siemens

1FN3050-8SA00-0AA0

MFR #1FN3050-8SA00-0AA0

SKU #YLSPEYTCHSLPEPH

1FN3100-8SA00-0AA0
View Details

Siemens

1FN3100-8SA00-0AA0

MFR #1FN3100-8SA00-0AA0

SKU #YLSJZNRPZ4VXXL

1FN3150-8SA00-0AA0
View Details

Siemens

1FN3150-8SA00-0AA0

MFR #1FN3150-8SA00-0AA0

SKU #YLSZOWEGFUAGXOH

1FN3300-8SA00-0AA0
View Details

Siemens

1FN3300-8SA00-0AA0

MFR #1FN3300-8SA00-0AA0

SKU #YLSZMAEBPCROKIZ

1FN3450-8SA00-0AA0
View Details

Siemens

1FN3450-8SA00-0AA0

MFR #1FN3450-8SA00-0AA0

SKU #YLSNONBMS6EF28

1FN3600-8SA00-0AA0
View Details

Siemens

1FN3600-8SA00-0AA0

MFR #1FN3600-8SA00-0AA0

SKU #YLS8CPR47M6DMNJ

1FN3900-8SA00-0AA0
View Details

Siemens

1FN3900-8SA00-0AA0

MFR #1FN3900-8SA00-0AA0

SKU #YLSQEN1CGSWWALU

1FY2105-0AA00
View Details

Siemens

1FY2105-0AA00

MFR #1FY2105-0AA00

SKU #YLSGTZWOTRQID

1FY2105-4AA00
View Details

Siemens

1FY2105-4AA00

MFR #1FY2105-4AA00

SKU #YLSDLAYIMNHTZJE

Featured Products

VFSWDM3546T-5E
Baldor VFSWDM3546T-5E
View Details

Baldor

VFSWDM3546T-5E

MFR #VFSWDM3546T-5E

SKU #YLSRYYEFOOW6J5E

CM2B40-75Z
SMC CM2B40-75Z
View Details

SMC

CM2B40-75Z

MFR #CM2B40-75Z

SKU #YLSOGLJ512KWTEJ

AW20-N02CG-6CZ-B
SMC AW20-N02CG-6CZ-B
View Details

SMC

AW20-N02CG-6CZ-B

MFR #AW20-N02CG-6CZ-B

SKU #YLSNOOF0IBCZ3J3

EH22512
Danfoss Aeroquip LLC EH22512
View Details

Danfoss Aeroquip LLC

EH22512

MFR #EH22512

SKU #YLSRZ91UGVO64DG

MY1M20-200AH
SMC MY1M20-200AH
View Details

SMC

MY1M20-200AH

MFR #MY1M20-200AH

SKU #YLSIZ8K8N4KBPBQ

VM8001-5
Baldor VM8001-5
View Details

Baldor

VM8001-5

MFR #VM8001-5

SKU #YLS3TOWVXWW0DHP

MGPM25-100Z-XC4
SMC MGPM25-100Z-XC4
View Details

SMC

MGPM25-100Z-XC4

MFR #MGPM25-100Z-XC4

SKU #YLSH71U0VZZBO5I

VQC2101R-51
SMC VQC2101R-51
View Details

SMC

VQC2101R-51

MFR #VQC2101R-51

SKU #YLSSEY6NT0YLZ8G

Related Searches

Siemens 6AG1134-6JF00-2CA1 priceSiemens 6AG1134-6JF00-2CA1 quotebuy Siemens 6AG1134-6JF00-2CA16AG1134-6JF00-2CA1 price6AG1134-6JF00-2CA1 stock availabilitySiemens spare partsSiemens 6AG1134-6JF00-2CA1 equivalentSiemens 6AG1134-6JF00-2CA1 specifications