Cookie Notice

We use cookies on our website to provide you with a better experience. Cookies are used to improve site performance, personalize content, and analyze traffic.

Siemens 3RT2028-2XB40-0LA2

Photo may not represent actual item. Refer to name and product specs for all details.

Siemens 3RT2028-2XB40-0LA2

traction contactor, AC-3e/AC-3, 38 A, 18.5 kW / 400 V, 3-pole, 24 V DC, 0.7-1.25* Uc, solid-state operating mechanism, with integrated varistor, auxiliary contacts: 1 NO + 1 NC, spring-loaded terminal, frame size: S0

SiemensMFR # 3RT2028-2XB40-0LA2SKU # CEY-8EF3B0393CA2
product brand nameSIRIUS
product designationPower contactor
design of the productWith extended operating range
product type designation3RT2
size of contactorS0
function module for communicationNo
Share

About This Product

traction contactor, AC-3e/AC-3, 38 A, 18.5 kW / 400 V, 3-pole, 24 V DC, 0.7-1.25* Uc, solid-state operating mechanism, with integrated varistor, auxiliary contacts: 1 NO + 1 NC, spring-loaded terminal, frame size: S0

Siemens 3RT2028-2XB40-0LA2

  • Genuine, certified Siemens product
  • Fast sourcing through a worldwide supply network
  • Product selection and compatibility support from our technical team
  • Equivalent and alternative product suggestions
  • Quotation and lead time tailored to your request

Specifications

product brand nameSIRIUS
product designationPower contactor
design of the productWith extended operating range
product type designation3RT2
General technical data
size of contactorS0
function module for communicationNo
auxiliary switchYes
at AC in hot operating state11.4 W
at AC in hot operating state per pole3.8 W
without load current share typical1.4 W
type of calculation of power loss current-dependentquadratic
of main circuit with degree of pollution 3 rated value690 V
of auxiliary circuit with degree of pollution 3 rated value690 V
of main circuit rated value6 kV
of auxiliary circuit rated value6 kV
maximum permissible voltage for protective separation between coil and main contacts according to EN 60947-1400 V
at DC10g / 5 ms, 7,5g / 10 ms
at DC15 g / 5 ms, 10 g / 10 ms
of contactor typical10 000 000
of the contactor with added electronically optimized auxiliary switch block typical5 000 000
of the contactor with added auxiliary switch block typical10 000 000
reference code according to IEC 81346-2Q
Substance Prohibitance (day/month/year)10/01/2009
SVHC substance nameLead CAS-No. 7439-92-1 Lead monoxide (lead oxide) CAS-No. 1317-36-8 2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-No. 71868-10-5 Melamine CAS-No. 108-78-1
Net Weight0.596 kg
Ambient conditions
installation altitude at height above sea level maximum2 000 m
during operation-40 ... +70 °C
during storage-55 ... +80 °C
relative humidity minimum10 %
relative humidity at 55 °C according to IEC 60068-2-30 maximum95 %
Main circuit
number of poles for main current circuit3
number of NO contacts for main contacts3
at AC-3 rated value maximum690 V
at AC-3e rated value maximum690 V
at AC-1 at 400 V at ambient temperature 40 °C rated value50 A
— up to 690 V at ambient temperature 40 °C rated value50 A
— up to 690 V at ambient temperature 60 °C rated value42 A
at AC-2 at 400 V rated value38 A
— at 400 V rated value38 A
— at 500 V rated value32 A
— at 690 V rated value21 A
— at 400 V rated value38 A
— at 500 V rated value32 A
— at 690 V rated value21 A
at AC-4 at 400 V rated value22 A
at maximum AC-1 rated value10 mm²
at maximum Ith rated value10 mm²
at 400 V rated value12 A
at 690 V rated value12 A
— at 24 V rated value35 A
— at 110 V rated value4.5 A
— at 220 V rated value1 A
— at 440 V rated value0.4 A
— at 600 V rated value0.25 A
— at 24 V rated value35 A
— at 110 V rated value35 A
— at 220 V rated value5 A
— at 440 V rated value1 A
— at 600 V rated value0.8 A
— at 24 V rated value35 A
— at 110 V rated value35 A
— at 220 V rated value35 A
— at 440 V rated value2.9 A
— at 600 V rated value1.4 A
— at 24 V rated value20 A
— at 110 V rated value2.5 A
— at 220 V rated value1 A
— at 440 V rated value0.09 A
— at 600 V rated value0.06 A
— at 24 V rated value35 A
— at 110 V rated value15 A
— at 220 V rated value3 A
— at 440 V rated value0.27 A
— at 600 V rated value0.16 A
— at 24 V rated value35 A
— at 110 V rated value35 A
— at 220 V rated value10 A
— at 440 V rated value0.6 A
— at 600 V rated value0.6 A
at AC-2 at 400 V rated value18.5 kW
— at 230 V rated value11 kW
— at 400 V rated value18.5 kW
— at 500 V rated value18.5 kW
— at 690 V rated value18.5 kW
— at 230 V rated value11 kW
— at 400 V rated value18.5 kW
— at 500 V rated value18.5 kW
— at 690 V rated value18.5 kW
at 400 V rated value6 kW
at 690 V rated value10.3 kW
limited to 1 s switching at zero current maximum593 A; Use minimum cross-section acc. to AC-1 rated value
limited to 5 s switching at zero current maximum341 A; Use minimum cross-section acc. to AC-1 rated value
limited to 10 s switching at zero current maximum260 A; Use minimum cross-section acc. to AC-1 rated value
limited to 30 s switching at zero current maximum199 A; Use minimum cross-section acc. to AC-1 rated value
limited to 60 s switching at zero current maximum162 A; Use minimum cross-section acc. to AC-1 rated value
at DC1 500 1/h
at AC-1 maximum750 1/h
at AC-2 maximum750 1/h
at AC-3 maximum750 1/h
— maximum750 1/h
at AC-2 at AC-3e maximum750 1/h
at AC-4 maximum250 1/h
Ratings for railway applications
up to 40 °C according to IEC 60077 rated value50 A
up to 70 °C according to IEC 60077 rated value38 A
Control circuit/ Control
type of voltageDC
type of voltage of the control supply voltageDC
control supply voltage at DC rated value24 V
initial value0.7
full-scale value1.25
design of the surge suppressorwith varistor
inrush current peak3 A
duration of inrush current peak30 µs
pickup current mean value0.3 A
pickup current peak0.52 A
duration of pickup current180 ms
holding current mean value45 mA
closing power of magnet coil at DC6.7 W
holding power of magnet coil at DC1.4 W
at DC50 ... 75 ms
at DC30 ... 50 ms
arcing time10 ms
control version of the switch operating mechanismStandard A1 - A2
Auxiliary circuit
number of NC contacts for auxiliary contacts1
instantaneous contact1
number of NO contacts for auxiliary contacts1
instantaneous contact1
operational current at AC-12 maximum10 A
at 230 V rated value10 A
at 400 V rated value3 A
at 500 V rated value2 A
at 690 V rated value1 A
at 24 V rated value10 A
at 48 V rated value6 A
at 60 V rated value6 A
at 110 V rated value3 A
at 125 V rated value2 A
at 220 V rated value1 A
at 600 V rated value0.15 A
at 24 V rated value10 A
at 48 V rated value2 A
at 60 V rated value2 A
at 110 V rated value1 A
at 125 V rated value0.9 A
at 220 V rated value0.3 A
at 600 V rated value0.1 A
UL/CSA ratings
at 480 V rated value34 A
at 600 V rated value27 A
— at 110/120 V rated value3 hp
— at 230 V rated value5 hp
— at 200/208 V rated value10 hp
— at 220/230 V rated value10 hp
— at 460/480 V rated value25 hp
— at 575/600 V rated value25 hp
contact rating of auxiliary contacts according to ULA600 / Q600
UL File Number (CCN)E31519 (NLDX, NLDX7)
Short-circuit protection
design of the miniature circuit breaker for short-circuit protection of the auxiliary circuit up to 230 VC characteristic: 10 A; 0.4 kA
— with type of coordination 1 requiredgG: 125 A (690 V,100 kA), aM: 50 A (690 V,100 kA), BS88: 125 A (415 V,80 kA)
— with type of coordination 2 requiredgG: 50 A (690 V, 100 kA), aM: 25 A (690 V, 100 kA), BS88: 50 A (415 V, 80 kA)
for short-circuit protection of the auxiliary switch requiredgG: 10 A (690 V, 1 kA)
Installation/ mounting/ dimensions
mounting position+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface
fastening method side-by-side mountingYes
fastening methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
height102 mm
width45 mm
depth107 mm
— forwards10 mm
— upwards10 mm
— downwards10 mm
— at the side0 mm
— forwards10 mm
— upwards10 mm
— at the side6 mm
— downwards10 mm
— forwards10 mm
— upwards10 mm
— downwards10 mm
— at the side6 mm
Connections/ Terminals
for main current circuitspring-loaded terminals
for auxiliary and control circuitspring-loaded terminals
at contactor for auxiliary contactsSpring-type terminals
of magnet coilSpring-loaded terminal
— solid2x (1 ... 10 mm²)
— solid or stranded2x (1 ... 10 mm²)
— finely stranded with core end processing2x (1 ... 6 mm²)
— finely stranded without core end processing2x (1 ... 6 mm²)
for AWG cables for main contacts2x (18 ... 8)
— solid or stranded2x (0.5 ... 2.5 mm²)
— finely stranded with core end processing2x (0.5 ... 1.5 mm²)
— finely stranded without core end processing2x (0.5 ... 2.5 mm²)
for AWG cables for auxiliary contacts2x (20 ... 14)
AWG number as coded connectable conductor cross section for main contacts18 ... 8
AWG number as coded connectable conductor cross section for auxiliary contacts20 ... 14
Safety related data
mirror contact according to IEC 60947-4-1Yes
positively driven operation according to IEC 60947-5-1No
suitable for safety functionYes
suitability for use safety-related switching OFFYes
service life maximum20 a
test wear-related service life necessaryYes
with low demand rate according to SN 3192040 %
with high demand rate according to SN 3192073 %
B10 value with high demand rate according to SN 319201 000 000
failure rate [FIT] with low demand rate according to SN 31920100 FIT
ISO 13849
device type according to ISO 13849-13
overdimensioning according to ISO 13849-2 necessaryYes
IEC 61508
safety device type according to IEC 61508-2Type A
Electrical Safety
protection class IP on the front according to IEC 60529IP20
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front
Communication/ Protocol
product function bus communicationNo

Accessories 54

Genuine accessories that can be used with the Siemens 3RT2028-2XB40-0LA2 motor and are supplied separately are listed below. Click a code to open the accessory page and see the other compatible motors.

Part noDescriptionCompatible motors
3RT2926-1ER00Aksesuar · Surge suppressor · diode assemblies
3RH2911-2HA22Aksesuar · Auxiliary switch · auxiliary switches
3RH2911-2FA22Aksesuar · Auxiliary switch · auxiliary switches
3RT2926-1CB00Aksesuar · Surge suppressor · RC elements
3RH2911-2XA22-0MA0Aksesuar · Auxiliary switch · auxiliary switches
3RH2911-2FA40Aksesuar · Auxiliary switch · auxiliary switches
3RH2911-2HA11Aksesuar · Auxiliary switch · auxiliary switches
3RH2921-2DE11Aksesuar · Auxiliary switch · auxiliary switches
3RH2911-2HA31Aksesuar · Auxiliary switch · auxiliary switches
3RH2911-2HA12Aksesuar · Auxiliary switch · auxiliary switches
3RH2911-2XA40-0MA0Aksesuar · Auxiliary switch · auxiliary switches
3RH2911-2HA01Aksesuar · Auxiliary switch · auxiliary switches
3RH2911-2XA31-0MA0Aksesuar · Auxiliary switch · auxiliary switches
3RA2813-2FW10Aksesuar
3RT2927-2PA01Aksesuar · Pneumatic delay blocks · pneumatic delay blocks
3RT2927-2PR01Aksesuar · Pneumatic delay blocks · pneumatic delay blocks
3RH2911-2FA04Aksesuar · Auxiliary switch · auxiliary switches
3RH2911-2HA03Aksesuar · Auxiliary switch · auxiliary switches
3RH2911-2FB22-0MA0Aksesuar · Auxiliary switch · auxiliary switches
3RH2911-2HA10Aksesuar · Auxiliary switch · auxiliary switches
3RH2911-2HA21Aksesuar · Auxiliary switch · auxiliary switches
3RH2911-2HA30Aksesuar · Auxiliary switch · auxiliary switches
3RH2911-2NE21Aksesuar · Auxiliary switch · auxiliary switches
3RH2911-2XA04-0MA0Aksesuar · Auxiliary switch · auxiliary switches
3RH2911-2NL22Aksesuar · Auxiliary switch · auxiliary switches
3RH2911-2XA13-0MA0Aksesuar · Auxiliary switch · auxiliary switches
3RH2911-2XA20-0MA0Aksesuar · Auxiliary switch · auxiliary switches
3RH2911-2XB22-0MA0Aksesuar · Auxiliary switch · auxiliary switches
3RH2916-2XA22-0MA0Aksesuar · Auxiliary switch · auxiliary switches
3RT2927-2PA11Aksesuar · Pneumatic delay blocks · pneumatic delay blocks
3RT2927-2PR11Aksesuar · Pneumatic delay blocks · pneumatic delay blocks
3RH2911-2NF20Aksesuar · Auxiliary switch · auxiliary switches
3RH2911-2XA11-0MA0Aksesuar · Auxiliary switch · auxiliary switches
3RH2911-2NF11Aksesuar · Auxiliary switch · auxiliary switches
3RH2911-2NF22Aksesuar · Auxiliary switch · auxiliary switches
3RH2911-2HA13Aksesuar · Auxiliary switch · auxiliary switches
3RT2926-1MR00Aksesuar · Surge suppressor · diode assemblies
3RH2916-2FA22Aksesuar · Auxiliary switch · auxiliary switches
3RA2813-2AW10Aksesuar
3RA2814-2AW10Aksesuar
3RA2814-2FW10Aksesuar
3RA2815-2AW10Aksesuar
3RA2815-2FW10Aksesuar
3RH2911-2NF02Aksesuar · Auxiliary switch · auxiliary switches
3RH2921-2DA11Aksesuar · Auxiliary switch · auxiliary switches
3RH2921-2DA20Aksesuar · Auxiliary switch · auxiliary switches
3RH2911-2NL40Aksesuar · Auxiliary switch · auxiliary switches
3RH2911-2HA02Aksesuar · Auxiliary switch · auxiliary switches
3RH2911-2HA20Aksesuar · Auxiliary switch · auxiliary switches
3RH2911-2FB11Aksesuar · Auxiliary switch · auxiliary switches
3RH2911-2FB22Aksesuar · Auxiliary switch · auxiliary switches
3RH2911-2FC22Aksesuar · Auxiliary switch · auxiliary switches
3RH2921-2DA02Aksesuar · Auxiliary switch · auxiliary switches
3RH2911-2NM31Aksesuar · Auxiliary switch · auxiliary switches

Related Products

3MV8100-0MB00
Siemens 3MV8100-0MB00
View Details

Siemens

3MV8100-0MB00

MFR #3MV8100-0MB00

SKU #YLSTQVYRHTPPWXE

3MV8100-0MC00
Siemens 3MV8100-0MC00
View Details

Siemens

3MV8100-0MC00

MFR #3MV8100-0MC00

SKU #YLSNDRLO7GD0JC3

3MV8100-0MD00
Siemens 3MV8100-0MD00
View Details

Siemens

3MV8100-0MD00

MFR #3MV8100-0MD00

SKU #YLSLDR7SAMNEI7

3MV8100-0ME00
Siemens 3MV8100-0ME00
View Details

Siemens

3MV8100-0ME00

MFR #3MV8100-0ME00

SKU #YLSQYIXF5Z6DOGW

3MV8100-0MF00
Siemens 3MV8100-0MF00
View Details

Siemens

3MV8100-0MF00

MFR #3MV8100-0MF00

SKU #YLSE4VVERJVVVFH

3MV8100-0MG00
Siemens 3MV8100-0MG00
View Details

Siemens

3MV8100-0MG00

MFR #3MV8100-0MG00

SKU #YLSI4OKULAP3QK

3MV8100-0MH00
Siemens 3MV8100-0MH00
View Details

Siemens

3MV8100-0MH00

MFR #3MV8100-0MH00

SKU #YLSCUEFEDHRZRUJ

3MV8100-0MJ00
Siemens 3MV8100-0MJ00
View Details

Siemens

3MV8100-0MJ00

MFR #3MV8100-0MJ00

SKU #YLSMBKZVBRAS5T

3MV8100-0MK00
Siemens 3MV8100-0MK00
View Details

Siemens

3MV8100-0MK00

MFR #3MV8100-0MK00

SKU #YLS3JCVHPICJ2VL

3MV8100-0ML00
Siemens 3MV8100-0ML00
View Details

Siemens

3MV8100-0ML00

MFR #3MV8100-0ML00

SKU #YLSMFZC3SXLCXHP

Featured Products

ZCUKQ25-50D
SMC ZCUKQ25-50D
View Details

SMC

ZCUKQ25-50D

MFR #ZCUKQ25-50D

SKU #YLSQ684QXTNN958

AR30-N02E-1Z-B
SMC AR30-N02E-1Z-B
View Details

SMC

AR30-N02E-1Z-B

MFR #AR30-N02E-1Z-B

SKU #YLSYFNHADE6GRKV

MXQ25-40B-M9NZ
SMC MXQ25-40B-M9NZ
View Details

SMC

MXQ25-40B-M9NZ

MFR #MXQ25-40B-M9NZ

SKU #YLST5TX9LNATRNS

NCDJ2L10-300-B
SMC NCDJ2L10-300-B
View Details

SMC

NCDJ2L10-300-B

MFR #NCDJ2L10-300-B

SKU #YLSRRDWPL50RWQ2

BC8M12
Brush Research Mfg BC8M12
View Details

Brush Research Mfg

BC8M12

MFR #BC8M12

SKU #YLSA0P5BE6ZJCIW

MDBB63-100Z
SMC MDBB63-100Z
View Details

SMC

MDBB63-100Z

MFR #MDBB63-100Z

SKU #YLSNBPQBGLI90UX

VQ1200-51-Q
SMC VQ1200-51-Q
View Details

SMC

VQ1200-51-Q

MFR #VQ1200-51-Q

SKU #YLSOVA6N31QD04G

EH22512
Danfoss Aeroquip LLC EH22512
View Details

Danfoss Aeroquip LLC

EH22512

MFR #EH22512

SKU #YLSRZ91UGVO64DG

MGPL25TN-200BZ-XC9
SMC MGPL25TN-200BZ-XC9
View Details

SMC

MGPL25TN-200BZ-XC9

MFR #MGPL25TN-200BZ-XC9

SKU #YLSPBI637NOCN0Y

Related Searches

Siemens 3RT2028-2XB40-0LA2 priceSiemens 3RT2028-2XB40-0LA2 quotebuy Siemens 3RT2028-2XB40-0LA23RT2028-2XB40-0LA2 price3RT2028-2XB40-0LA2 stock availabilitySiemens spare partsSiemens 3RT2028-2XB40-0LA2 equivalentSiemens 3RT2028-2XB40-0LA2 specifications