
Siemens
1EE1122-..A00-...4
MFR #1EE1122-..A00-...4
SKU #YLS3FGFZLYE3EV8
Web sitemizde size daha iyi bir deneyim sunmak için çerezler kullanıyoruz. Çerezler, site performansını artırmak, içerikleri kişiselleştirmek ve trafiği analiz etmek için kullanılır.

Fotoğraf, ürünün gerçek halini yansıtmayabilir. Tüm detaylar için ürünün adına ve özelliklerine bakınız.
Device: 7SJ82 overcurrent protection Product code Short: P1J126344 Long: 7SJ82-DAAA-AA0-0AAAA0-AH0211-12111B-AAA000-000AB0-HB1BD2-JZ0 Enclosure width : 1/3 x 19" Enclosure type: Installation Binary inputs 11 Binary outputs 9 standard relays Current transformer: 4 for protection, 0 for measurement and sensitive earth current acquisition Current transformer: 4 Transmitter inputs: 0 (20 mA or 10 V, fast) 0 (20mA) CPU: CP100 Modules in 19" row 1: IO102 , PS101 Modules in 19" row 2: Number of LEDs: 16 Operating unit Integrated Key-operated switch: without display type: Small display front design: standard Auxiliary voltage: 24 V / 48 V DC Communication / plug-in modules: Communication encryption Normal Integrated Ethernet port J: for DIGSI 5 Plug-in module position E: ETH-BA-2EL: 2 x electrical Ethernet, RJ45, suitable for DIGSI, IEC 61850, DNP etc. Plug-in module position F: Port is available, but not equipped UL NRGU.E194016 / cUL NRGU7.E194016 Functions: Function points class: Basis + 100 function points ANSI: functions (included in the base) protection functions for 3-pole resolution, 37 Undercurrent 38 Temperature monitoring, 46 Negative-sequence system overcurrent protection, 46 Phase balance current protection (thermal), 49 Thermal overload protection, 50N/ 51N TD Time overcurrent protection, Ground, 50HS High-speed overcurrent protection, -- Fast tripping when switching on to a fault, 50N/ 51N TD Time overcurrent protection, 1-phase, 50Ns/ 51Ns Sensitive ground current protection for deleted and isola Networks, 74TC Trip circuit supervision, 86 Lockout AFD Arc protection (only with plug-in module ARC-CD-3FO), -- Measured values, standard, -- Switching statistics, -- CFC (standard, control), -- Switching sequence function, -- Inrush-current detection, -- External trip initiation, -- Control, -- Fault recording of analog and binary signals -- Monitoring, -- Protection interface, serial
Device: 7SJ82 overcurrent protection Product code Short: P1J126344 Long: 7SJ82-DAAA-AA0-0AAAA0-AH0211-12111B-AAA000-000AB0-HB1BD2-JZ0 Enclosure width : 1/3 x 19" Enclosure type: Installation Binary inputs 11 Binary outputs 9 standard relays Current transformer: 4 for protection, 0 for measurement and sensitive earth current acquisition Current transformer: 4 Transmitter inputs: 0 (20 mA or 10 V, fast) 0 (20mA) CPU: CP100 Modules in 19" row 1: IO102 , PS101 Modules in 19" row 2: Number of LEDs: 16 Operating unit Integrated Key-operated switch: without display type: Small display front design: standard Auxiliary voltage: 24 V / 48 V DC Communication / plug-in modules: Communication encryption Normal Integrated Ethernet port J: for DIGSI 5 Plug-in module position E: ETH-BA-2EL: 2 x electrical Ethernet, RJ45, suitable for DIGSI, IEC 61850, DNP etc. Plug-in module position F: Port is available, but not equipped UL NRGU.E194016 / cUL NRGU7.E194016 Functions: Function points class: Basis + 100 function points ANSI: functions (included in the base) protection functions for 3-pole resolution, 37 Undercurrent 38 Temperature monitoring, 46 Negative-sequence system overcurrent protection, 46 Phase balance current protection (thermal), 49 Thermal overload protection, 50N/ 51N TD Time overcurrent protection, Ground, 50HS High-speed overcurrent protection, -- Fast tripping when switching on to a fault, 50N/ 51N TD Time overcurrent protection, 1-phase, 50Ns/ 51Ns Sensitive ground current protection for deleted and isola Networks, 74TC Trip circuit supervision, 86 Lockout AFD Arc protection (only with plug-in module ARC-CD-3FO), -- Measured values, standard, -- Switching statistics, -- CFC (standard, control), -- Switching sequence function, -- Inrush-current detection, -- External trip initiation, -- Control, -- Fault recording of analog and binary signals -- Monitoring, -- Protection interface, serial

Siemens
MFR #1EE1122-..A00-...4
SKU #YLS3FGFZLYE3EV8

Siemens
MFR #1EE1124-..A00-...4
SKU #YLSKZIN1GEIPRVP

Siemens
MFR #1EE1142-..A00-...4
SKU #YLSUX3MNEZEJGPU

Siemens
MFR #1EE1144-..A00-...4
SKU #YLSD9GON9QOYBAE

Siemens
MFR #1EE1322-....0-...4
SKU #YLSSAVZE8P7OOP6

Siemens
MFR #1EE1322-...00-1..2
SKU #YLSY69IQB2JXAXJ

Siemens
MFR #1EE1322-..A00-...4
SKU #YLSH1E6AJR6XWJF

Siemens
MFR #1EE1324-....0-...4
SKU #YLS8GBB9BXAF83

Siemens
MFR #1EE1324-...00-1..2
SKU #YLSLOS6I1BDXR58

Siemens
MFR #1EE1324-..A00-...4
SKU #YLSE0T3LUEU0CI

Baldor
MFR #VFSWDM3546T-5E
SKU #YLSRYYEFOOW6J5E

Baldor
MFR #VM8001-5
SKU #YLS3TOWVXWW0DHP

SMC
MFR #AR30-N02E-1Z-B
SKU #YLSYFNHADE6GRKV

SMC
MFR #MY1M20-200AH
SKU #YLSIZ8K8N4KBPBQ

SMC
MFR #VQ1200-51-Q
SKU #YLSOVA6N31QD04G

Danfoss Aeroquip LLC
MFR #EH22512
SKU #YLSRZ91UGVO64DG

SMC
MFR #MGPM25-100Z-XC4
SKU #YLSH71U0VZZBO5I

SMC
MFR #MGPL25TN-200BZ-XC9
SKU #YLSPBI637NOCN0Y

SMC
MFR #CM2B40-75Z
SKU #YLSOGLJ512KWTEJ

SMC
MFR #MXQ25-40B-M9NZ
SKU #YLST5TX9LNATRNS
Siemens P1J126344 fiyatSiemens P1J126344 teklif alSiemens P1J126344 satın alP1J126344 fiyatP1J126344 stok durumuSiemens yedek parçaSiemens P1J126344 muadilSiemens P1J126344 teknik özellikler