product type designation
product brand nameSCALANCE
product type designationXCM320
transfer rate
transfer rate10, 100, 1000 Mbit/s
interfaces / for communication / integrated
for network components or terminal equipment8; RJ45
with securing collar8
for SFP+8
interfaces / other
for operator console1
for signaling contact1
for power supply1
for operator consoleUSB (2,0 type B, USB-to-serial adapter)
for signaling contact2-pole terminal block
for power supply2 x 2-pole terminal block
CLPVar
at DC / rated value24 V
at DC / maximum0,1 A
supply voltage, current consumption, power loss
product component / connection for redundant voltage supplyVar
type of voltage / 1 / of the supply voltageDC
supply voltage / 1 / rated value24 V
power loss [W] / 1 / rated value43,2 W
power loss [W] / at DC / at 24 V / typical25,92 W
supply voltage / 1 / voltage range19,2... 28,8
consumed current / 1 / maximum1,8 A
consumed current / at DC / at 24 V / typical1,08 A
type of electrical connection / 1 / for power supply2 x 2-pole terminal block
product component / 1 / fusing at power supply inputVar
fuse protection type / 1 / at input for supply voltageF 10 A / 250 V
ambient conditions
during operation-40... +60 °C
during storage-40... +85 °C
during transport-40... +85 °C
at 25 °C / without condensation / during operation / maximum95 %
operating condition / fanless operationVar
protection class IPIP20
design, dimensions and weights
designcompact
width210 mm
height147 mm
depth125 mm
net weight1,8 kg
19-inch installationYok
35 mm DIN-rail mountingVar
wall mountingVar
S7-300 rail mountingVar
S7-1500 rail mountingVar
product features, product functions, product components / general
product conformity / according to IEEE 802.1Qbu and IEEE 802.3br (Frame Preemption)Var
product license
product license / Upgrade licenseVar; layer 3 license
product functions / management, configuration, engineering
CLIVar
web-based managementVar
MIB supportVar
TRAPs via emailVar
configuration with STEP 7Var
RMONYok
port mirroringVar
multiport mirroringVar
Encapsulated Remote Traffic Mirroring (ERTM)Var
CoSVar
PROFINET IO diagnosisVar
switch-managedVar
PROFINET conformity classB
network load class / according to PROFINETII
telegram length / for Ethernet / maximum9194 bayt
TelnetYok
HTTPVar
HTTPSVar
TFTPVar
FTPVar
SFTPVar
BOOTPYok
NETCONFVar
GMRPVar
DCPVar
LLDPVar
EtherNet/IPVar
SNMP v1Var
SNMP v2Var
SNMP v3Var
IGMP (snooping/querier)Var
I&M0 - device-specific informationVar
I&M1 - higher level designation/location designationVar
product functions / diagnostics
port diagnosticsVar
statistics Packet SizeVar
statistics packet typeVar
error statisticsVar
SysLogVar
product functions / VLAN
VLAN - port basedVar
VLAN - protocol-basedYok
VLAN - IP-basedYok
VLAN dynamicVar
number of VLANs / maximum2048
number of VLANs - dynamic / maximum2048
product functions / DHCP
DHCP serverYok
DHCP clientVar
DHCP Option 82Yok
DHCP Option 66Var
DHCP Option 67Var
product functions / redundancy
protocol / is supported / Media Redundancy Protocol (MRP)Var
media redundancy protocol (MRP) with redundancy managerVar
Media Redundancy Protocol Interconnection (MRP-I)Yok
ring redundancyVar
high speed redundancy protocol (HRP) with redundancy managerYok
high speed redundancy protocol (HRP) with standby redundancyYok
redundancy procedure STPVar
redundancy procedure RSTPVar
redundancy procedure RSTP+Yok
redundancy procedure MSTPVar
passive listeningVar
eRSTPVar
LACPVar
product functions / security
RADIUSVar
SSHVar
SSLVar
product functions / time
SICLOCK supportVar
NTP-clientVar
IEEE 1588 v2 transparent forwardingVar
NTPVar
IEEE 1588 profile defaultVar
standards, specifications, approvals
CE markingVar
UKCA markingVar
cULus approvalVar
KC onayıVar
Regulatory Compliance Mark (RCM)Var
product conformity / according to EMC-guideline2014/30/EU
for EMC interference emissionEN 61000-6-4
for immunity to EMCEN 61000-6-2
for safety / from CSA and ULUL-61010-2 E85972
standards, specifications, approvals / hazardous environments
ATEXVar
UKEXVar
IECExVar
ULhazloc approvalVar
CCC / for hazardous zone according to GB standardVar
FM registrationVar
standards, specifications, approvals / other
railway application in accordance with EN 50121-4Var; use only in areas not accessible to the public
railway application in accordance with EN 50125-3Var; Section 4,2: Class AX (up to 2000m); section 4,3: T1: Containers N.T.C ve T.C. / Buildings N.C.C ve C.C, T2: Containers N.T.C ve T.C. / Buildings N.C.C ve C.C, TX: Containers N.T.C ve T.C. / Buildings N.C.C ve C.C., derating according to the manual must be observed when SFP/SFP+ transceivers are used --> only for variants with optical connections; In addition, depending on the installation position, the derating according to the manual must be taken into account; section 4,4: T1: Containers C.C. / Buildings N.C.C ve C.C., T2: Containers C.C. / Buildings N.C.C ve C.C, T3: Containers C.C. / Buildings N.C.C ve C.C; section 4,11: C1: Indoor, C2: Indoor (except condensation), C3: Indoor (except condensation), 4B1, 4S10, UL 61010-2-10; section 4,13: partially, Test Fc: Vibration EN 60068-2-6; IEC 60068-2-6, Test Ea: Shock EN 60068-2-27; IEC 60068-2-27, Test Ec: Rough handling, shocks EN 60068-2-31; IEC 60068-2-31; section 4,14: yes; section 4,15: yes, according to manual.
RoHS conformityVar
resistance to air pollution / conformity according to ANSI/ISA-71.04Var; G3
IT security for industrial automation systems / according to IEC 62443-4-2:2019Var
product functions / general
MTBF16,8 a
warranty period5 a
product function / is supported / identification linkVar; acc. to IEC 61406-1:2022