Genel bilgiler
Ürün tipi tanımıCPU 1504D TF
HW functional statusFS13
Firmware sürümüPLC: V3.1 / SINAMICS dahili: V5.2 SP3
FW update possibleVar; PLC up to V3.1 / SINAMICS dahili up to V5.2 SP3
based onSIMATIC S7-1500 TF-CPU ve SINAMICS S120
Product function
I&M dataVar; I&M0 to I&M3
Isochronous modeVar; With minimum OB 6x cycle of 500 µs
SysLogVar
Mühendislik aracı
STEP 7 TIA Portal configurable/integrated from versionV21 (FW V3.1) / V16 (FW V2.8) veya üstü
Integrated drive control
Number of axes for servo control, max.6
Number of axes for vector control, max.6
Number of axes for V/f control, max.12
Remarkalternative control modes; drive control based on SINAMICS S120 CU320-2 (firmware version V5.x); functional subset compared to CU320-2: no free function blocks,...; for details, see the manual
Configuration control
via datasetVar
Control elements
Number of keys1; FUNCT button
Mode selector switch1
Besleme gerilimi
Nominal değer (DC)24 V
İzin verilen aralık, alt sınır (DC)20,4 V
İzin verilen aralık, üst sınır (DC)28,8 V
Ters polarite korumasıVar
Mains buffering
Mains/voltage failure stored energy time3 ms; Refers to the power supply on the CPU section
Repeat rate, min.1 event every 10 s
Giriş akımı
Akım tüketimi (nominal değer)0,65 A; Without load on inputs/outputs, without supply via DRIVE- CLiQ/USB interface
Akım tüketimi, maks.13,1 A; With load
Ani çekiş akımı, maks.6 A; Rated value
I²t0,62 A²·s
Güç kaybı
Güç kaybı, tipik17 W
Storage
Number of slots for SIMATIC memory card1
SIMATIC memory card requiredVar
Çalışma belleği
integrated (for program)4 MB
integrated (for data)6 MB
Yükleme belleği
Plug-in (SIMATIC Memory Card), required12 MB; Recommended least when dahili drive is used
Takılabilir (SIMATIC Memory Card), maks.32 Gbyte
Yedekleme
Bakım gerektirmezVar
CPU blokları
Eleman sayısı (toplam)20.000; Blocks (OB, FB, FC, DB) ve UDTs
DB
Number range1... 60.999; subdivided into: number range that can be used by the user: 1... 59.999, ve number range of DBs created via SFC 86: 60.000... 60.999
Boyut, maks.6 MB; For DBs with absolute addressing, the maks. size is 64 KB
FB
Number range0... 65.535
Boyut, maks.1 MB
FC
Number range0... 65.535
Boyut, maks.1 MB
Organizasyon blokları (OB)
Boyut, maks.1 MB
Number of free cycle OBs100
Number of time alarm OBs20
Number of delay alarm OBs20
Number of cyclic interrupt OBs20; with minimum OB 3x cycle of 100 µs
Number of process alarm OBs50
Number of DPV1 alarm OBs3
Number of isochronous mode OBs3
Number of technology synchronous alarm OBs2
Number of startup OBs100
Number of asynchronous error OBs4
Number of synchronous error OBs2
Number of diagnostic alarm OBs1
Nesting depth
per priority class24; Up to 8 possible for F-blocks
S7 counter
Number2.048
Retentivity
— adjustableVar
IEC counter
NumberAny (only limited by the main memory)
Retentivity
— adjustableVar
S7 timer
Number2.048
Retentivity
— adjustableVar
IEC timer
NumberAny (only limited by the main memory)
Retentivity
— adjustableVar
Veri alanları ve kalıcılığı
Kalıcı veri alanı (zamanlayıcı, sayıcı, merker dahil), maks.700 kB; in toplam; for bit memories, timers, counters, DBs, ve technology data (axes)
Merker (bayrak)
Boyut, maks.16 kB
Number of clock memories8; 8 clock memory bit, grouped into one clock memory bayt
Data blocks
Retentivity adjustableVar
Retentivity presetYok
Yerel veri
Öncelik sınıfı başına, maks.64 kB; maks. 16 KB per block
Address area
Number of IO modules16.384; maks. number of modules / submodules
I/O address area
Inputs32 kB; All inputs are in the process image
Outputs32 kB; All outputs are in the process image
per integrated IO subsystem
— Inputs (volume)32 kB; Maks. 32 KB via X150; maks. 8 KB via X160 veya X126
— Outputs (volume)32 kB; Maks. 32 KB via X150; maks. 8 KB via X160 veya X126
Subprocess images
Number of subprocess images, max.32
Donanım yapılandırması
Number of distributed IO systems64; A distributed I/O system is characterized not only by the integration of distributed I/O via PROFINET veya PROFIBUS, but also by the connection of I/O via AS-i master modules veya links (e.g. IE/PB-Link)
Number of DP masters
Dahili1
Via CMExpansion via CMs / CPs (PROFIBUS, PROFINET, Ethernet) not possible; these CMs / CPs can only be operated in a central rack
Number of IO Controllers
Dahili2
via CMExpansion via CMs / CPs (PROFIBUS, PROFINET, Ethernet) not possible; these CMs / CPs can only be operated in a central rack
PtP CM
Number of PtP CMsThe number of connectable PtP CMs (distributed) is only limited by the number of available slots
Saat
TypeHardware clock
Yedekleme süresi6 wk; At 40 °C ambient temperature, typically
Günlük sapma, maks.10 s; Typ.: 2,4 s
Operating hours counter
Number16
Clock synchronization
DestekleniyorVar
to DP, masterVar
on DP, deviceVar
in AS, masterVar
in AS, deviceVar
on Ethernet via NTPVar
Dijital girişler
integrated channels (DI)28; maks. depending on parameterization
Digital inputs, parameterizableVar; 12 DI, 8 DI/DQ (X122/X132, SINAMICS dahili) + 8 DI/DQ (X142, PLC)
Kaynak/çeken girişP-reading
Input characteristic curve in accordance with IEC 61131, type 3Var
Digital input functions, parameterizable
Freely usable digital inputVar; Maks. 20 (X122/X132) + maks. 8 (X142)
ProbeVar; Maks. 8 (X122/X132) + maks. 8 (X142)
Digital input with time stampVar; Maks. 8 (X142); e.g. for probes
CounterVar; Maks. 8 (X142); event/cycle duration measurement
Digital input with oversamplingVar; Maks. 8 (X142); 32-fold oversampling
Giriş gerilimi
Type of input voltageDC
Nominal değer (DC)24 V
“0” sinyali için-3 to +5V
“1” sinyali için+11 to +30V
permissible voltage at input, min.-3 V
permissible voltage at input, max.30 V
Giriş akımı
for signal "1", typ.4 mA
Input delay (for rated value of input voltage)
Minimum pulse width for program reactions5 µs; for X122/X132/X142 (DI/DQ as DI; for X142 with filter setting 1 µs)
Standart girişler için
— ParametrelenebilirYok; For X122/X132
— with "0" to "1", typ.For X122/X132: 10 µs (DI) / 5 µs (DI/DQ as DI)
— with "1" to "0", typ.For X122/X132: 30 µs (DI) / 5 µs (DI/DQ as DI)
Kesme girişleri için
— ParametrelenebilirVar; identical to those teknolojik fonksiyonlar için
Teknolojik fonksiyonlar için
— ParametrelenebilirVar; For X142, additionally adjustable input filter: 1 µs / 125 µs
— with "0" to "1", typ.5 µs; For X142; HW delay
— with "1" to "0", typ.5 µs; For X142; HW delay
Kablo uzunluğu
Ekranlı, maks.30 m; For technological functions: Shielding of the DI recommended depending on the requirements
Ekransız, maks.30 m
Dijital çıkışlar
Type of digital outputTransistor
integrated channels (DO)16; maks. depending on parameterization
Current-sinkingVar; With High Speed output
Current-sourcingVar; Optionally as a P-switch veya high-speed push-pull switch (high-speed output)
Digital outputs, parameterizableVar; 8 DI/DQ (X122/X132, SINAMICS dahili) + 8 DI/DQ (X142, PLC)
Short-circuit protectionVar; electronic/thermal
Response threshold, typ.X122/X132: 1,4 A / X142: 0,9 A (high-speed output: 0,7 A)
Endüktif kapatma geriliminin sınırlandırılmasıX122/X132: maks. -60 V / X142: maks. -64.5 V
Controlling a digital inputVar
minimum pulse duration2 µs; For high-speed output, single pulse
Digital output functions, parameterizable
Freely usable digital outputVar; Maks. 8 (X122/X132) + maks. 8 (X142)
Digital output with time stampVar; Maks. 8 (X142); e.g. for output cams
PWM outputVar; Maks. 8 (X142)
— Cycle duration, parameterizableVar; Base frequency 1 / 2 / 4 / 8 / 16 kHz; specification of interpulse period ratio over 32-bit pattern
— ON period, min.0 %
— ON period, max.100 %
— Resolution of the duty cycle3,125 %
Digital output with oversamplingVar; Maks. 8 (X142)
Çıkışların anahtarlama kapasitesi
Omik yükte, maks.0,5 A; 0,4 A for high-speed output
Lamba yükünde, maks.5 W
Load resistance range
lower limit48 Ω; with 24 V DC supply
Çıkış gerilimi
Type of output voltageDC
Nominal değer (DC)24 V
“0” sinyali için, maks.28,8 V
“1” sinyali için, min.20,4 V
Çıkış akımı
“1” sinyali için nominal değer0,5 A; 0,4 A for high-speed output
for signal "1" permissible range, min.2 mA
for signal "1" permissible range, max.0,6 A; 0,44 A for high-speed output
Omik yükte çıkış gecikmesi
"0" to "1", typ.100 µs; For X122/X132; 48 ohm load
"1" to "0", typ.150 µs; For X122/X132; 48 ohm load
Teknolojik fonksiyonlar için
— "0" to "1", typ.1 µs; For X142
— "1" to "0", typ.1 µs; For X142 as a high-speed output; 150 µs for standard output
Parallel switching of two outputs
for logic linksVar; For technological functions ve high-speed outputs: Yok
for upratingYok
for redundant control of a loadVar; For technological functions ve high-speed outputs: Yok
Anahtarlama frekansı
Omik yükte, maks.35 kHz; With High Speed output, 1 kHz with standard output
with inductive load, max.2 Hz; Maks. 1 J per channel
Lamba yükünde, maks.11 Hz
Total current of the outputs
Current per module, max.8 A
Kablo uzunluğu
Ekranlı, maks.30 m
Ekransız, maks.30 m
Arayüzler
PROFINET arayüz sayısı3
Number of PROFIBUS interfaces1
Number of USB interfaces2; USB 3,0 (without function, no connection permissible)
Number of DRIVE-CLiQ interfaces4; DRIVE-CLiQ interfaces (24 V / 450 mA per interface for connecting encoders/measuring systems)
Arayüz tipleri
RJ 45 (Ethernet)Var; X150
Port sayısı3
Dahili switchVar
Protokoller
IP protocolVar; IPv4
PROFINET IO kontrolcüsüVar
PROFINET IO DeviceVar
SIMATIC haberleşmesiVar
Açık IE haberleşmesiVar; Optionally also encrypted
Web sunucusuVar
Ortam yedekliliğiVar
Servisler
— Eşzamanlı (isochronous) modVar
— Direct data exchangeVar; Requirement: IRT ve isochronous mode (MRPD optional)
— IRTVar
— Dinamik çerçeve paketleme (DFP)Var
— PROFIenergyVar; per user program
— Önceliklendirilmiş başlatmaVar; Maks. 32 PROFINET devices
— Bağlanabilir IO cihazı sayısı, maks.256; In toplam, up to 1.000 distributed I/O devices can be connected via AS-i, PROFIBUS veya PROFINET
— Of which IO devices with IRT, max.64
— RT için bağlanabilir IO cihazı sayısı, maks.256
— Bunlardan hat üzerinde, maks.256
— Eşzamanlı etkinleştirilebilen/devre dışı bırakılabilen IO cihazı sayısı, maks.8; in toplam across all interfaces
— Number of IO Devices per tool, max.8
— Updating timesThe minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, ve on the quantity of configured user data
— PROFINET Security Class1
Update time for IRT
— for send cycle of 500 µs500 µs to 8 ms
— for send cycle of 1 ms1 ms to 16 ms
— for send cycle of 2 ms2 ms to 32 ms
— for send cycle of 4 ms4 ms to 64 ms
— With IRT and parameterization of "odd" send cyclesUpdate time = set "odd" send clock (any multiple of 125 µs: 375 µs, 625 µs... 3.875 µs)
Update time for RT
— for send cycle of 500 µs500 µs to 256 ms
— for send cycle of 1 ms1 ms to 512 ms
— for send cycle of 2 ms2 ms to 512 ms
— for send cycle of 4 ms4 ms to 512 ms
Servisler
— Eşzamanlı (isochronous) modYok
— IRTVar
— Dinamik çerçeve paketleme (DFP)Yok
— PROFIenergyVar; per user program
— Önceliklendirilmiş başlatmaYok
— Paylaşımlı cihazVar
— Paylaşımlı cihazlı IO kontrolcüsü sayısı, maks.4
— activation/deactivation of I-devicesVar; per user program
— Varlık yönetimi kaydıVar; per user program
— PROFINET Security ClassSNMP Configuration ve DCP Read Only
Arayüz tipleri
RJ 45 (Ethernet)Var; X160
Port sayısı1
Dahili switchYok
Protokoller
IP protocolVar; IPv4
PROFINET IO kontrolcüsüVar
PROFINET IO DeviceVar
SIMATIC haberleşmesiVar
Açık IE haberleşmesiVar; Optionally also encrypted
Web sunucusuVar
Ortam yedekliliğiYok
Servisler
— Eşzamanlı (isochronous) modYok
— Direct data exchangeYok
— IRTYok
— PROFIenergyVar; per user program
— Önceliklendirilmiş başlatmaYok
— Bağlanabilir IO cihazı sayısı, maks.128; In toplam, up to 1.000 distributed I/O devices can be connected via AS-i, PROFIBUS veya PROFINET
— RT için bağlanabilir IO cihazı sayısı, maks.128
— Bunlardan hat üzerinde, maks.128
— Eşzamanlı etkinleştirilebilen/devre dışı bırakılabilen IO cihazı sayısı, maks.8; in toplam across all interfaces
— IO Devices changing during operation (partner ports), supportedVar
— Number of IO Devices per tool, max.8
— Updating timesThe minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, ve on the quantity of configured user data
— PROFINET Security Class1
Update time for RT
— for send cycle of 1 ms1 ms to 512 ms
Servisler
— Eşzamanlı (isochronous) modYok
— IRTYok
— PROFIenergyVar; per user program
— Önceliklendirilmiş başlatmaYok
— Paylaşımlı cihazVar
— Paylaşımlı cihazlı IO kontrolcüsü sayısı, maks.4
— activation/deactivation of I-devicesVar; per user program
— Varlık yönetimi kaydıVar; per user program
— PROFINET Security ClassSNMP Configuration ve DCP Read Only
Arayüz tipleri
RJ 45 (Ethernet)Var; X130
Port sayısı1
Dahili switchYok
Protokoller
IP protocolVar; IPv4
PROFINET IO kontrolcüsüYok
PROFINET IO cihazıYok
SIMATIC haberleşmesiVar
Açık IE haberleşmesiVar; Optionally also encrypted
Web sunucusuVar
Arayüz tipleri
RS 485Var; X126
Port sayısı1
Protokoller
PROFIBUS DP masterVar
PROFIBUS DP deviceYok
SIMATIC haberleşmesiVar
PROFIBUS DP master
Number of connections, max.48; for the dahili PROFIBUS DP interface
max. number of DP devices125; In toplam, up to 1.000 distributed I/O devices can be connected via AS-i, PROFIBUS veya PROFINET
Servisler
— EquidistanceVar
— Eşzamanlı (isochronous) modVar
— activation/deactivation of DP devicesVar
RJ 45 (Ethernet)
100 MbpsVar
1000 MbpsVar; Only the X130 interface
Otomatik anlaşma (autonegotiation)Var
Otomatik çaprazlama (autocrossing)Var
Industrial Ethernet status LEDVar; LINK ve ACTIVITY
RS 485
İletim hızı, maks.12 Mbit/s
Protokoller
PROFIsafeVar; V2.4 / V2.6 (V2.6 yalnızca şununla: PROFINET)
Bağlantı sayısı
Number of connections, max.384; Via dahili interfaces of the CPU
Number of connections reserved for ES/HMI/web10
Number of connections via integrated interfaces320
Number of S7 routing paths64; in toplam, only 16 S7-Routing connections are supported via PROFIBUS
Yedeklilik modu
PROFINET sistem yedekliliği (S2)Yok
PROFINET sistem yedekliliği (R1)Yok
H-Sync forwardingVar
Ortam yedekliliği
— Media redundancyonly via interface X150
— MRPVar; MRP Automanager according to IEC 62439-2 Edition 2,0, MRP Manager; MRP Client
— MRP ara bağlantısı, destekleniyorVar; as MRP ring node according to IEC 62439-2 Edition 3,0
— MRPDVar; Requirement: IRT
— Switchover time on line break, typ.200 ms; For MRP, bumpless for MRPD
— Number of stations in the ring, max.50
SIMATIC haberleşmesi
PG/OP communicationVar; encryption with TLS V1.3 pre-selected
S7 yönlendirmeVar
Data record routingVar
S7 communication, as serverVar
S7 communication, as clientVar
İş başına kullanıcı verisi, maks.See online help (S7 communication, user data size)
Açık IE haberleşmesi
TCP/IPVar
— Veri uzunluğu, maks.64 kB
— several passive connections per port, supportedVar
ISO-on-TCP (RFC1006)Var
— Veri uzunluğu, maks.64 kB
UDPVar
— Veri uzunluğu, maks.2 kB; 1.472 bytes for UDP broadcast
— UDP multicastVar; 128 multicast circuits (of which maks. 5 via X150)
DHCPVar
DNSVar
SNMPVar
DCPVar
LLDPVar
EncryptionVar; Optional
Web sunucusu
HTTPVar; Standard ve user pages
HTTPSVar; Standard ve user pages
— Oturum sayısı, maks.200
— number of simultaneous HTTP calls, max.4
— HTTP request body, max.131.072 bayt
OPC UA
Çalışma zamanı lisansı gerekirVar; "Small" license required
OPC UA ClientVar; Data Access (registered Read/Write), Method Call
— Uygulama kimlik doğrulamasıVar
— Security policiesAvailable security policies: Yok, Basic128Rsa15, Basic256Rsa15, Basic256Sha256
— Kullanıcı kimlik doğrulaması"anonymous" veya by user name & password
— Number of connections, max.40
— Number of nodes of the client interfaces, recommended max.5.000
— Number of elements for one call of OPC_UA_NodeGetHandleList/OPC_UA_ReadList/OPC_UA_WriteList, max.300
— Number of elements for one call of OPC_UA_NameSpaceGetIndexList, max.20
— Number of elements for one call of OPC_UA_MethodGetHandleList, max.100
— Number of simultaneous calls of the client instructions for session management, per connection, max.1
— Number of simultaneous calls of the client instructions for data access, per connection, max.5
— Number of registerable nodes, max.5.000
— Number of registerable method calls of OPC_UA_MethodCall, max.100
— Number of inputs/outputs when calling OPC_UA_MethodCall, max.20
OPC UA sunucusuVar; Data Access (Read, Write, Subscribe), Method Call, Alarms & Condition (A&C), Custom Address Space
— Uygulama kimlik doğrulamasıVar
— Security policiesavailable security policies: Yok, Basic128Rsa15, Basic256Rsa15, Basic256Sha256, Aes128Sha256RsaOaep, Aes256Sha256RsaPss
— Kullanıcı kimlik doğrulaması"anonymous" veya by user name & password
— GDS support (certificate management)Var
— Oturum sayısı, maks.64
— Number of accessible variables, max.200.000
— Number of registerable nodes, max.50.000
— Oturum başına abonelik sayısı, maks.50
— Örnekleme aralığı, min.10 ms
— Yayınlama aralığı, min.10 ms
— Sunucu metodu sayısı, maks.100
— Number of inputs/outputs per server method, max.20
— İzlenen öğe sayısı, önerilen maks.10.000; for 1 s sampling interval ve 1 s send interval
— Sunucu arayüzü sayısı, maks.10 of her biri "Server interfaces" / "Companion specification" type ve 20 of the type "Reference namespace"
— Kullanıcı tanımlı sunucu arayüzleri için düğüm sayısı, maks.50.000
Alarms and ConditionsVar
— Number of program alarms400
— Number of alarms for system diagnostics200
Diğer protokoller
MODBUSVar; MODBUS TCP
Isochronous mode
EquidistanceVar
Jitter, max.1 µs
S7 message functions
Number of login stations for message functions, max.64
number of subscriptions, max.750
number of tags/attributes for subscriptions, max.50.000
Program alarmsVar
Number of configurable program messages, max.10.000; Program messages are generated by the "Program_Alarm" block, ProDiag veya GRAPH
Number of loadable program messages in RUN, max.10.000
Number of program alarms4.000
Number of alarms for system diagnostics1.000
Number of alarms for motion technology objects480
Test commissioning functions
Joint commission (Team Engineering)Var; Parallel online access possible for up to 10 engineering systems
Status blockVar; Up to 16 simultaneously (in toplam across all ES clients)
Single stepYok
Number of breakpoints20
ProfilingYok
Durum/kontrol
Durum/kontrol değişkeniVar; without fail-safe
Değişkenlerinputs/outputs, bit memories, DBs, peripheral I/Os (without fail-safe), times, counters
— of which status variables, max.200; per job
— of which control variables, max.200; per job
Zorlama (force)
Zorlama (force)Var; without fail-safe
Forcing, variablesperipheral inputs/outputs (without fail-safe)
Number of variables, max.200
Tanılama arabelleği
MevcutVar
Number of entries, max.3.200
— of which powerfail-proof1.000
İzlemeler (trace)
Yapılandırılabilir izleme sayısı8
İzleme başına bellek boyutu, maks.512 kB
Tanılama gösterge LED’i
RUN/STOP LED’iVar
ERROR LED’iVar
MAINT LED’iVar
ACT LEDVar; For memory card access
RDY LEDVar
COM LEDVar
Connection display LINK TX/RXVar
Supported technology objects
Motion ControlVar; Note: The number of technology objects affects the cycle time of the PLC program; selection guide via the TIA Selection Tool
Number of available Motion Control resources for technology objects3.200
— per speed-controlled axis40
— per positioning axis80
— per synchronous axis160
— per external encoder80
— per output cam20
— per cam track160
— per probe40
Number of available Extended Motion Control resources for technology objects160
— per cam (1 000 points and 50 segments)2
— per cam (10 000 points and 50 segments)20
— for each set of kinematics30
— per Interpreter60
— Per leading axis proxy3
— kinematics with up to 4 interpolating axesVar; maks. 3D + orientation
— kinematics with 5 or more interpolating axesYok
— user-defined kinematicsVar
— SIMATIC Safe KinematicsYok
— Number of positioning axes at motion control cycle of 4 ms (typical value)12
— Number of positioning axes at motion control cycle of 8 ms (typical value)24
PID_CompactVar; Universal PID controller with dahili optimization
PID_3StepVar; PID controller with dahili optimization for valves
PID-TempVar; PID controller with dahili optimization for temperature
High-speed counterVar
Entegre fonksiyonlar
Sayıcı sayısı8; Event/cycle duration measurement
Sayma frekansı, maks.32 kHz
Counting functions
Continuous countingVar
Measuring range
— Cycle duration measurement, min.10 µs; 5 µs minimum pulse width
— Cycle duration measurement, max.178 s
Accuracy
— Cycle duration measurementSampling of the time period with 41,67 ns increments
Dijital girişlerde potansiyel ayrımı
Kanallar arasıVar; 12 DI (X122/X132), in 2 groups of 6 DI her biri
Dijital çıkışlarda potansiyel ayrımı
Kanallar arasıYok; 8 DI/DQ (X122/X132) ve 8 DI/DQ (X142)
Koruma derecesi ve sınıfı
IP koruma sınıfıIP20 control cabinet installation / open type
Standartlar, onaylar, sertifikalar
Siemens Eco Profile (SEP)Siemens EcoTech
CE işaretiVar
UKCA markVar
cULusVar
RCM (eski adıyla C-TICK)Var
KC onayıVar
EAC (formerly Gost-R)Var
Ekolojik ayak izi
Çevresel ürün beyanıVar
Küresel ısınma potansiyeli
— Küresel ısınma potansiyeli (toplam) [CO₂ eşd.]403 kg
— Küresel ısınma potansiyeli (üretim sırasında) [CO₂ eşd.]107 kg
— Küresel ısınma potansiyeli (çalışma sırasında) [CO₂ eşd.]306 kg
— Küresel ısınma potansiyeli (ömür sonrası) [CO₂ eşd.]-10.7 kg
Highest safety class achievable in safety mode
Performance level according to ISO 13849-1PLd (PLe if exclusively F-CPU is used)
SIL acc. to IEC 61508SIL 2 (SIL 3 if exclusively F-CPU is used)
Probability of failure (for service life of 20 years and repair time of 100 hours)
— Low demand mode: PFDavg in accordance with SIL2< 14.00E-04
— Low demand mode: PFDavg in accordance with SIL3< 2.00E-05 PLd (if exclusively F-CPU is used)
— High demand/continuous mode: PFH in accordance with SIL2< 14.00E-09
— High demand/continuous mode: PFH in accordance with SIL3if exclusively F-CPU is used: < 1.00E-09 ( a site altitude of up to 3000 m); < 2.00E-09 ( a site altitude of more than 3000 m ve up to 4000 m)
Security
PROFINET Security Class1
signed firmware updateVar
safely removing dataVar
Çalışma ortam sıcaklığı
min.0 °C
maks.55 °C
Depolama/taşıma ortam sıcaklığı
min.-40 °C; Long-term storage: -25 °C
maks.70 °C; Long-term storage: +55 °C
Deniz seviyesine göre çalışma yüksekliği
Installation altitude above sea level, max.4.000 m; as of an altitude of 2000 m, the maximum ambient air temperature is reduced by 7 °C per 1000 m; see SINAMICS documentation for SINAMICS S120 drive components
Ambient air temperature-barometric pressure-altitudePermissible air pressure: 620 hPa... 1.060 hPa
Programlama dili
— LADVar; incl. failsafe
— FBDVar; incl. failsafe
— STLVar
— SCLVar
— CFCYok
— GRAPHVar
Know-how koruması
Kullanıcı programı/şifre korumasıVar
Kopya korumasıVar
Blok korumasıVar
Erişim koruması
Gizli yapılandırma verisinin korunmasıVar
Koruma seviyesi: yazma korumasıVar
Koruma seviyesi: okuma/yazma korumasıVar
Protection level: Write protection for FailsafeVar
Koruma seviyesi: tam korumaVar
Kullanıcı yönetimiVar
Çevrim süresi izleme
lower limitadjustable minimum cycle time
upper limitadjustable maximum cycle time
Ölçüler
Genişlik50 mm
Yükseklik300 mm
Derinlik226 mm; 270 mm with spacer (included in scope of supply)
Ağırlık
Ağırlık, yaklaşık2.400 g
Other
Note:The SIMATIC Drive Controller deviates from the usual SIMATIC S7-1500 ambient conditions ve specifications as well as the available approvals ve certificates because of the drive design. For details, see the SIMATIC Drive Controller device ve system manual. Operation is without fan.