Product function
Isochronous modeYok
Giriş akımı
from backplane bus 5 V DC, max.90 mA
Güç kaybı
Güç kaybı, tipik0,4 W
Analog girişler
Analog giriş sayısı8
For resistance measurement8
permissible input voltage for voltage input (destruction limit), max.30 V; 12 V continuous, 30 V for maks. 1 s
permissible input current for current input (destruction limit), max.40 mA
Giriş aralıkları
GerilimVar
CurrentVar
ThermocoupleYok
Resistance thermometerVar
ResistanceVar
Giriş aralıkları (nominal değerler), gerilim
0 … +10 VVar
— Giriş direnci (0 … 10 V)100 kΩ
1 V to 5 VVar
— Input resistance (1 V to 5 V)100 kΩ
1 V to 10 VYok
-1 V to +1 VVar
— Input resistance (-1 V to +1 V)100 kΩ
-10 V to +10 VVar
— Input resistance (-10 V to +10 V)100 kΩ
-2.5 V to +2.5 VYok
-250 mV to +250 mVYok
-5 V to +5 VVar
— Input resistance (-5 V to +5 V)100 kΩ
-50 mV to +50 mVVar
— Input resistance (-50 mV to +50 mV)100 kΩ
-500 mV to +500 mVVar
— Input resistance (-500 mV to +500 mV)100 kΩ
-80 mV to +80 mVYok
Input ranges (rated values), currents
0 … 20 mAVar
— Input resistance (0 to 20 mA)100 Ω
-10 mA to +10 mAYok
-20 mA to +20 mAVar
— Input resistance (-20 mA to +20 mA)100 Ω
-3.2 mA to +3.2 mAYok
4 mA to 20 mAVar
— Input resistance (4 mA to 20 mA)100 Ω
Input ranges (rated values), thermocouples
Type BYok
Type CYok
Type EYok
Type JYok
Type KYok
Type LYok
Type NYok
Type RYok
Type SYok
Type TYok
Type UYok
Type TXK/TXK(L) to GOSTYok
Input ranges (rated values), resistance thermometer
Cu 10Yok
Ni 100Var; Standard/climate
— Input resistance (Ni 100)100 MΩ
Ni 1000Var
— Input resistance (Ni 1000)100 MΩ
LG-Ni 1000Var; Standard/climate
— Input resistance (LG-Ni 1000)100 MΩ
Ni 120Yok
Ni 200Yok
Ni 500Yok
Pt 100Var; Standard/climate
— Input resistance (Pt 100)100 MΩ
Pt 1000Yok
Pt 200Yok
Pt 500Yok
Input ranges (rated values), resistors
0 to 150 ohmsYok
0 to 300 ohmsYok
0 to 600 ohmsVar
— Input resistance (0 to 600 ohms)100 MΩ
0 to 6000 ohmsVar
— Input resistance (0 to 6000 ohms)100 MΩ
Temperature compensation
— ParametrelenebilirYok
— internal temperature compensationYok
— external temperature compensation with compensations socketYok
Characteristic linearization
ParameterizableVar
— for thermocouplesYok
— for resistance thermometeryes; Pt100 standard/air con.; Ni100 standard/air con.; Ni1000 standard/air con.; LG-Ni1000 standard/air con.
Kablo uzunluğu
Ekranlı, maks.200 m; maks. 50 m 50 mV
Kanal başına entegrasyon/dönüşüm süresi ve çözünürlük
Aşım dahil çözünürlük (işaret biti dahil), maks.13 bit
Entegrasyon süresi, parametrelenebilirVar; 60 / 50 ms
Basic conversion time (ms)66 / 55 ms
Interference voltage suppression for interference frequency f1 in Hz50 / 60 Hz
Connection of signal encoders
for voltage measurementVar
for current measurement as 2-wire transducerVar; with external supply
for current measurement as 4-wire transducerVar
for resistance measurement with two-wire connectionVar
for resistance measurement with three-wire connectionVar
for resistance measurement with four-wire connectionVar
Operational error limit in overall temperature range
Voltage, relative to input range, (+/-)0,6 %; ±0,6 % (±5 V, 10 V, 1 to 5 V, 0 to 10 V); ±0,5 % (±50 mV, 500 mV, 1 V)
Current, relative to input range, (+/-)0,5 %; ±20 mA, 0 to 20 mA, 4 to 20 mA
Resistance, relative to input range, (+/-)0,5 %; 0 to 6 kohms, 0 to 600 kohms
Resistance thermometer, relative to input range, (+/-)1 Kelvin (Pt100, Ni100, climatic; Ni1000, LG-Ni1000, standard; Ni1000, LG-Ni1000, climatic); 1,2 Kelvin (Pt100, Ni100, standard)
Basic error limit (operational limit at 25 °C)
Voltage, relative to input range, (+/-)0,4 %; 0,4% (±5 V, 10 V, 1 to 5 V, 0 to 10 V); 0,3% (±50 mV, 500 mV, 1 V)
Current, relative to input range, (+/-)0,3 %; ±20 mA, 0 to 20 mA, 4 to 20 mA
Resistance, relative to input range, (+/-)0,3 %; 0 to 6 kohms, 0 to 600 kohms
Resistance thermometer, relative to input range, (+/-)1 Kelvin (Pt100, Ni100, standard); 0,8 Kelvin (Pt100, Ni100, climatic; Ni1000, LG-Ni1000, standard; Ni1000, LG-Ni1000, climatic)
Interrupts/diagnostics/status information
Diagnostics functionYok
Alarms
Diagnostic alarmYok
Limit value alarmYok
Diagnoses
Diagnostic information readableYok
Tanılama gösterge LED’i
Group error SF (red)Yok
Potential separation analog inputs
Kanallar arasıYok
between the channels and backplane busVar
Isolation
Isolation tested with500 V DC
Connection method
required front connector40-pin
Ölçüler
Genişlik40 mm
Yükseklik125 mm
Derinlik117 mm
Ağırlık
Ağırlık, yaklaşık250 g