Genel bilgiler
Ürün tipi tanımıPN/J1939 LINK
FW update possibleVar
Vendor identification (VendorID)0x002A
based on6BK1623-0AA00-0AA0
Product function
I&M dataVar; I&M0 to I&M3
Isochronous modeYok
Mühendislik aracı
STEP 7 TIA Portal configurable/integrated from versionsee entry ID: 109746275
PROFINET from GSD version/GSD revisionGSDML V2.3.x
Installation type/mounting
MountingDIN rail, wall mounting, portrait mounting
Mounting positionany
Recommended mounting positionHorizontal
Rail mountingVar
Control cabinet installationVar
Besleme gerilimi
Type of supply voltageDC
Nominal değer (DC)24 V
İzin verilen aralık, alt sınır (DC)20,4 V
İzin verilen aralık, üst sınır (DC)28,8 V
Ters polarite korumasıVar
Overvoltage protectionVar
Short-circuit protectionVar
Mains buffering
Mains/voltage failure stored energy time10 ms; PN side
Giriş akımı
Akım tüketimi (nominal değer)0,09 A
Akım tüketimi, maks.0,11 A
Güç kaybı
Güç kaybı, tipik2,2 W
Arayüzler
Interfaces/bus type2x Ethernet (RJ45), 1x Sub-D (9-pin)
Supports protocol for PROFINET IO
İletim hızının otomatik algılanmasıYok
İletim hızı, maks.100 Mbit/s
Number of RJ45 ports2
Number of FC (FastConnect) connections2
PROFINET functions
Assignment of the IP address, supportedVar
Assignment of the device name, supportedVar
1. Arayüz
Arayüz tipiJ1939 according to the standard "SAE J1939"
İzoleliVar; 500 V AC veya 707 V DC
Arayüz tipleri
Port sayısı1
Design of the connection9-pin sub D socket
CAN
CAN operating modesJ1939 according to the standard "SAE J1939"
Transmission rate, min.100 kbit/s
İletim hızı, maks.500 kbit/s
max. number of devices30
J1939
Addressable ECUs, max.30
Logical nodes, max.253
PDU 1Var
PDU 2Var
DM dataVar
BAMVar
CMDTVar
2. Interface
Arayüz tipiPROFINET
İzoleliVar; 1.500 V AC veya 2.250 V DC
Arayüz tipleri
RJ 45 (Ethernet)Var
Port sayısı2
Dahili switchVar
Protokoller
PROFINET IO DeviceVar
Açık IE haberleşmesiVar
Interrupts/diagnostics/status information
Status indicatorVar
AlarmsVar
Diagnostics functionVar
Tanılama gösterge LED’i
RUN LEDVar
ERROR LED’iVar
MAINT LED’iVar
LINK LEDVar
RX/TX LEDVar
Potential separation
Potential separation existsVar
Isolation
Isolation tested with750 V DC (type test) ve according to EN 50155 (routine test)
Koruma derecesi ve sınıfı
IP koruma sınıfıIP20
Ekolojik ayak izi
Çevresel ürün beyanıVar
Küresel ısınma potansiyeli
— Küresel ısınma potansiyeli (toplam) [CO₂ eşd.]50,8 kg
— Küresel ısınma potansiyeli (üretim sırasında) [CO₂ eşd.]14,4 kg
— Küresel ısınma potansiyeli (çalışma sırasında) [CO₂ eşd.]36,8 kg
— Küresel ısınma potansiyeli (ömür sonrası) [CO₂ eşd.]-0.52 kg
Railway application
EN 50121-3-2Var; EMC for rail vehicles
EN 50121-4Var; EMC for signal ve telecommunications systems
EN 50124-1Var; Railway applications - overvoltage category OV2; pollution degree PD2; rated surge voltage UNi = 0,5 kV; UNm = 24 V DC
EN 50125-1Var; Rail vehicles - see ambient conditions
EN 50125-2Var; Stationary electrical equipment - see ambient conditions
EN 50125-3Var; Signal ve telecommunications systems - see ambient conditions; vibrations ve shocks: Application point outside of tracks (1 m to 3 m away from track)
EN 50155Var; Rail vehicles - temperature class OT4, ST1/ST2, yatay mounting position
EN 61373Var; Rail vehicles - vibrations ve shocks: Category 1 Class A/B
Fire protection acc. to EN 45545-2Var; For proof of conformity, see Service & Support
Çalışma ortam sıcaklığı
Yatay montaj, min.-40 °C; = Tmin (incl. condensation/frost)
Yatay montaj, maks.70 °C; = Tmax; +85 °C for 10 min (OT4, ST1/ST2 acc. to EN 50155)
Dikey montaj, min.-40 °C; = Tmin
Dikey montaj, maks.55 °C; = Tmax
ceiling installation, min.-40 °C; = Tmin
ceiling installation, max.45 °C; = Tmax
floor installation, min.-40 °C; = Tmin
floor installation, max.45 °C; = Tmax
Depolama/taşıma ortam sıcaklığı
min.-40 °C
maks.85 °C
Deniz seviyesine göre çalışma yüksekliği
Installation altitude above sea level, max.2.000 m
Ambient air temperature-barometric pressure-altitudeTmin... Tmax 1.140 hPa... 795 hPa (-1 000 m... +2.000 m)
Bağıl nem
With condensation, tested in accordance with IEC 60068-2-38, max.100 %; RH incl. condensation / frost (no commissioning in bedewed state), yatay installation
Coolants and lubricants
— Resistant to commercially available coolants and lubricantsVar; Incl. diesel ve oil droplets in the air
Use in stationary industrial systems
— to biologically active substances according to EN 60721-3-3Var; Class 3B2 mold, fungus ve dry rot spores (with the exception of fauna); Class 3B3 talep üzerine
— to chemically active substances according to EN 60721-3-3Var; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
— to mechanically active substances according to EN 60721-3-3Var; Class 3S4 incl. sand, dust, *
Use on land craft, rail vehicles and special-purpose vehicles
— to biologically active substances according to EN 60721-3-5Var; Class 5B2 mold, fungus ve dry rot spores (with the exception of fauna); Class 5B3 talep üzerine
— to chemically active substances according to EN 60721-3-5Var; Class 5C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
— to mechanically active substances according to EN 60721-3-5Var; Class 5S3 incl. sand, dust; *
Usage in industrial process technology
— Against chemically active substances acc. to EN 60654-4Var; Class 3 (excluding trichlorethylene)
— Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04Var; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) ve level LB3 (oil)
Remark
— Note regarding classification of environmental conditions acc. to EN 60721, EN 60654-4 and ANSI/ISA-71.04* The supplied plug covers must remain in place over the unused interfaces during operation!
Conformal coating
Coatings for printed circuit board assemblies acc. to EN 61086Var; Class 2 for high reliability
Protection against fouling acc. to EN 60664-3Var; Type 1 protection
Electronic equipment on rolling stock acc. to EN 50155Var; Class PC2 protective coating acc. to EN 50155:2017
Military testing according to MIL-I-46058C, Amendment 7Var; Discoloration of coating possible during service life
Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830AVar; Conformal coating, Class A
Ölçüler
Genişlik70 mm
Yükseklik112 mm
Derinlik75 mm
Ağırlık
Ağırlık, yaklaşık212 g
Other
Note:for use in railway applications, also observe the product information "SIPLUS extreme RAIL" A5E37661960A, Online Support article 109736776