Genel bilgiler
Ürün tipi tanımıCM 4 x IO-Link ST
based on6ES7137-6BD00-0BA0
usable BaseUnitsBU type A0
Color code for module-specific color-coded labelCC04
Product function
I&M dataVar; I&M0 to I&M3
Isochronous modeYok; Only for PROFINET ve configuration as version with FW V2.0 veya V2.1
Mühendislik aracı
STEP 7 TIA Portal configurable/integrated from versionsee entry ID: 109746275
Operating mode
IO-LinkVar
DIVar
DQVar; maks. 100 mA per channel
Besleme gerilimi
Nominal değer (DC)24 V
İzin verilen aralık, alt sınır (DC)19,2 V; 20,5 V if IO-Link is used, as the supply voltage for IO-Link devices has to be least 20 V the master.
İzin verilen aralık, üst sınır (DC)28,8 V
Ters polarite korumasıVar
power supply according to NEC Class 2 requiredYok
Giriş akımı
Akım tüketimi, maks.45 mA; without load
Encoder supply
Number of outputs4
Çıkış akımı
Rated value700 mA; Per channel
24 V enkoder beslemesi
Short-circuit protectionVar
Output current, max.2,1 A
Güç kaybı
Güç kaybı, tipik1 W
Donanım yapılandırması
Automatic encodingVar
Electronic coding element type HVar
Kablo uzunluğu
Ekransız, maks.20 m; Also applies for shielded cables
IO-Link
Port sayısı4
of which simultaneously controllable4
IO-Link protocol 1.0Var
IO-Link protocol 1.1Var
Transmission rate4,8 kBaud (COM1); 38,4 kBaud (COM2), 230,4 kBaud (COM3)
Cycle time, min.2 ms; dynamic, depending on user data length
Size of process data, input per port32 bayt; maks.
Size of process data, input per module144 bayt; maks.
Size of process data, output per port32 bayt; maks.
Size of process data, output per module128 bayt; maks.
Memory size for device parameter2 kB; for her biri port
Master backupVar
Configuration without S7-PCTVar
Cable length unshielded, max.20 m
Time Based IO
TIO IO-Link INYok; Only for PROFINET ve configuration as version with FW V2.0 veya V2.1
TIO IO-Link OUTYok; Only for PROFINET ve configuration as version with FW V2.0 veya V2.1
TIO IO-Link IN/OUTYok; Only for PROFINET ve configuration as version with FW V2.0 veya V2.1
Connection of IO-Link devices
Port type AVar
Port type BVar; 24 V DC via external terminal
via three-wire connectionVar
Alarms
Diagnostic alarmVar; The port diagnosis is available in the IO-Link mode only.
Diagnoses
Monitoring the supply voltageVar
Wire breakVar
Short-circuitVar
Group errorVar
Tanılama gösterge LED’i
Monitoring of the supply voltage (PWR-LED)Var; green PWR LED
Channel status displayVar; one green LED for channel status Qn (SIO mode) ve port status Cn (IO-Link mode) per channel
for channel diagnosticsVar; red Fn LED
for module diagnosticsVar; green/red DIAG LED
Potential separation channels
Kanallar arasıYok
between the channels and backplane busVar
between the channels and the power supply of the electronicsYok
Isolation
Isolation tested with750 V DC (type test) ve according to EN 50155 (routine test)
Ekolojik ayak izi
Çevresel ürün beyanıVar
Küresel ısınma potansiyeli
— Küresel ısınma potansiyeli (toplam) [CO₂ eşd.]25,2 kg
— Küresel ısınma potansiyeli (üretim sırasında) [CO₂ eşd.]6,15 kg
— Küresel ısınma potansiyeli (çalışma sırasında) [CO₂ eşd.]19,4 kg
— Küresel ısınma potansiyeli (ömür sonrası) [CO₂ eşd.]-0.289 kg
Railway application
EN 50121-3-2Var; EMC for rail vehicles
EN 50121-4Var; EMC for signal ve telecommunications systems
EN 50121-5Var; EMC for fixed installations ve railway power supply equipment (shielded cables required)
EN 50124-1Var; Railway applications - overvoltage category OV2; pollution degree PD2; rated surge voltage UNi = 0,5 kV; UNm = 24 V DC
EN 50125-1Var; Rail vehicles - see ambient conditions
EN 50125-2Var; Stationary electrical equipment - see ambient conditions
EN 50125-3Var; Signal ve telecommunications systems - see ambient conditions; vibrations ve shocks: Application point outside of tracks (1 m to 3 m away from track)
EN 50155Var; Rail vehicles - temperature class OT2, ST1/ST2, yatay mounting position
EN 61373Var; Rail vehicles - vibrations ve shocks: Category 1 Class A/B
Fire protection acc. to EN 45545-2Var; For proof of conformity, see Service & Support
Çalışma ortam sıcaklığı
Yatay montaj, min.-40 °C; = Tmin (incl. condensation/frost)
Yatay montaj, maks.60 °C; = Tmax; +70 °C for 10 min (OT2, ST1/ST2 acc. to EN 50155); +70 °C continuously with spacing modules (6AG2193-6BN00-4BA0) veya configured slots to the left ve right of the module (OT4, ST0 acc. to EN 50155)
Dikey montaj, min.-40 °C; = Tmin
Dikey montaj, maks.50 °C; = Tmax
Deniz seviyesine göre çalışma yüksekliği
Installation altitude above sea level, max.2.000 m
Ambient air temperature-barometric pressure-altitudeTmin... Tmax 1.140 hPa... 795 hPa (-1 000 m... +2.000 m)
Bağıl nem
With condensation, tested in accordance with IEC 60068-2-38, max.100 %; RH incl. condensation / frost (no commissioning in bedewed state), yatay installation
Coolants and lubricants
— Resistant to commercially available coolants and lubricantsVar; Incl. diesel ve oil droplets in the air
Use in stationary industrial systems
— to biologically active substances according to EN 60721-3-3Var; Class 3B2 mold, fungus ve dry rot spores (with the exception of fauna); Class 3B3 talep üzerine
— to chemically active substances according to EN 60721-3-3Var; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
— to mechanically active substances according to EN 60721-3-3Var; Class 3S4 incl. sand, dust, *
— Against mechanical environmental conditions acc. to EN 60721-3-3Var; Class 3M8 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0)
Use on land craft, rail vehicles and special-purpose vehicles
— to biologically active substances according to EN 60721-3-5Var; Class 5B2 mold, fungus ve dry rot spores (with the exception of fauna); Class 5B3 talep üzerine
— to chemically active substances according to EN 60721-3-5Var; Class 5C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
— to mechanically active substances according to EN 60721-3-5Var; Class 5S3 incl. sand, dust; *
— Against mechanical environmental conditions acc. to EN 60721-3-5Var; Class 5M2 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0)
— against mechanical environmental conditions in agriculture acc. to ISO 15003Var; level 1 (Location LE) using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0)
Usage in industrial process technology
— Against chemically active substances acc. to EN 60654-4Var; Class 3 (excluding trichlorethylene)
— Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04Var; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) ve level LB3 (oil)
Remark
— Note regarding classification of environmental conditions acc. to EN 60721, EN 60654-4 and ANSI/ISA-71.04* The supplied plug covers must remain in place over the unused interfaces during operation!
Conformal coating
Coatings for printed circuit board assemblies acc. to EN 61086Var; Class 2 for high reliability
Protection against fouling acc. to EN 60664-3Var; Type 1 protection
Electronic equipment on rolling stock acc. to EN 50155Var; Class PC2 protective coating acc. to EN 50155:2017
Military testing according to MIL-I-46058C, Amendment 7Var; Discoloration of coating possible during service life
Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830AVar; Conformal coating, Class A
Ölçüler
Genişlik15 mm
Yükseklik73 mm
Derinlik58 mm
Ağırlık
Ağırlık, yaklaşık30 g
Other
Note:for use in railway applications, also observe the product information "SIPLUS extreme RAIL" A5E37661960A, Online Support article 109736776