product brand nameSIPLUS
transfer rate
at the 1st interface10... 1000 Mbit/s
at the 2nd interface10... 100 Mbit/s
interfaces
number of interfaces / according to Industrial Ethernet3
at the 1st interface / according to Industrial Ethernet1
at the 2nd interface / according to Industrial Ethernet2
for power supply1
at the 1st interface / according to Industrial EthernetRJ45 port
at the 2nd interface / according to Industrial EthernetRJ45 port
for power supply2-pole plugable terminal block
C-PLUGVar
supply voltage, current consumption, power loss
type of voltage / of the supply voltageDC
supply voltage / 1 / from backplane bus5 V
supply voltage / external24 V
supply voltage / external / at DC / rated value24 V
relative positive tolerance / at DC / at 24 V20 %
relative negative tolerance / at DC / at 24 V15 %
from backplane bus / at DC / at 5 V / typical0,14 A
from external supply voltage / at DC / at 24 V / typical0,48 A
from external supply voltage / at DC / at 24 V / maximum0,62 A
power loss [W]14,7 W
ambient conditions
for vertical installation / during operation0... 40 °C
for horizontally arranged busbars / during operation0... 60 °C
during storage-40... +70 °C
during transport-40... +70 °C
installation altitude / at height above sea level / maximum5000 m
ambient condition / relating to ambient temperature - air pressure - installation altitudeTmin... Tmax 1.140 hPa... 795 hPa (-1 000 m... +2.000 m) // Tmin... (Tmax - 10 K) 795 hPa... 658 hPa (+2.000 m... +3.500 m) // Tmin... (Tmax - 20 K) 658 hPa... 540 hPa (+3.500 m... +5.000 m)
with condensation / according to IEC 60068-2-38 / maximum100 %; RH including condensation/frost (no commissioning when condensation is present), yatay installation
chemical resistance / to commercially available cooling lubricantsVar; incl. airborne diesel ve oil droplets
conformity according to EN 60721-3-3Var; Class 3B2 mold ve fungal spores (excluding fauna), Class 3B3 talep üzerine
conformity according to EN 60721-3-6Var; Class 6B2 mold, fungal ve dry rot spores (excluding fauna)
conformity according to EN 60721-3-3Var; Class 3C4 (RH < 75 %) incl. salt spray in accordance with EN 60068-2-52 (Severity 3). The supplied plug covers must remain in place on the unused interfaces during operation.
conformity according to EN 60721-3-6Var
conformity according to EN 60721-3-3Var; Class 3S4 incl. sand, dust. The supplied plug covers must remain in place over the unused interfaces during operation.
conformity according to EN 60721-3-6Var; Class 6S3 incl. sand, dust. The supplied plug covers must remain in place over the unused interfaces during operation.
coating / for equipped printed circuit board / according to EN 61086Var; Class 2 for high availability
type of coating / protection against pollution according to EN 60664-3Var; Protection of the type 1
type of test / of the coating / according to MIL-I-46058CVar; Coating discoloration during service life possible
product conformity / of the coating / Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830AVar; Conformal coating, class A
protection class IPIP20
design, dimensions and weights
module formatCompact module
width80 mm
height125 mm
depth120 mm
net weight0,8 kg
S7-300 rail mountingVar
performance data / open communication
number of possible connections / for open communication / by means of SEND/RECEIVE blocks / maximum16
as user data per ISO connection / for open communication / by means of SEND/RECEIVE blocks / maximum8 Kibyte
as user data per ISO on TCP connection / for open communication / by means of SEND/RECEIVE blocks / maximum8 Kibyte
as user data per TCP connection / for open communication / by means of SEND/RECEIVE blocks / maximum8 Kibyte
as user data per UDP connection / for open IE communication / by means of SEND/RECEIVE blocks / maximum2 Kibyte
number of Multicast stations16
performance data / S7 communication
maximum16
performance data / multi-protocol mode
number of active connections / with multi-protocol mode48
performance data / IT functions
as client / by means of FTP / maximum10
as server / by means of FTP / maximum2
as server / by means of HTTP / maximum4
as email client / maximum1
data volume / as user data for email / maximum8 Kibyte
as flash memory file system28 Mibyte
as RAM30 Mibyte
number of possible write cycles / of the flash memory cells100000
performance data / PROFINET communication / as PN IO controller
product function / PROFINET IO controllerVar
number of PN IO devices / on PROFINET IO controller / operable / total128
number of PN IO IRT devices / on PROFINET IO controller / operable128
number of external PN IO lines / with PROFINET / per rack1
as user data for input variables / as PROFINET IO controller / maximum4 Kibyte
as user data for output variables / as PROFINET IO controller / maximum4 Kibyte
as user data for input variables per PN IO device / as PROFINET IO controller / maximum1433 bayt
as user data for output variables per PN IO device / as PROFINET IO controller / maximum1433 bayt
as user data for input variables per PN IO device / for each sub-module as PROFINET IO controller / maximum240 bayt
as user data for output variables per PN IO device / for each sub-module as PROFINET IO controller / maximum240 bayt
performance data / PROFINET communication / as PN IO device
product function / PROFINET IO deviceVar
as user data for input variables / as PROFINET IO device / maximum1024 bayt
as user data for output variables / as PROFINET IO device / maximum1024 bayt
as user data for input variables / for each sub-module as PROFINET IO device240 bayt
as user data for output variables / for each sub-module as PROFINET IO device240 bayt
as user data for the consistency area for each sub-module240 bayt
number of submodules / per PROFINET IO-Device32
performance data / PROFINET CBA
number of remote connection partners / with PROFINET CBA64
number of connections / with PROFINET CBA / total1000
as user data for digital inputs / with PROFINET CBA / maximum8 Kibyte
as user data for digital outputs / with PROFINET CBA / maximum8 Kibyte
as user data for arrays and data types / in the case of acyclic transmission / with PROFINET CBA / maximum8 Kibyte
as user data for arrays and data types / with PROFINET CBA / with cyclical transfer / maximum250 bayt
as user data for arrays and data types / with PROFINET CBA / in the case of local interconnection / maximum2400 bayt
performance data / PROFINET CBA / remote interconnection / with acyclic transfer
update time / of the remote interconnections / in the case of acyclic transmission / with PROFINET CBA100 ms
number of remote connections to input variables / in the case of acyclic transmission / with PROFINET CBA / maximum128
number of remote connections to output variables / in the case of acyclic transmission / with PROFINET CBA / maximum128
as user data for remote interconnections with input variables / in the case of acyclic transmission / with PROFINET CBA8 Kibyte
as user data for remote interconnections with output variables / in the case of acyclic transmission / with PROFINET CBA8 Kibyte
performance data / PROFINET CBA / remote interconnection / with cyclic transfer
update time / of the remote interconnections / with cyclical transfer / with PROFINET CBA8 ms
number of remote connections to input variables / with PROFINET CBA / with cyclic transfer / maximum200
number of remote connections to output variables / with cyclical transfer / with PROFINET CBA / maximum200
as user data for remote interconnections with input variables / with cyclical transfer / with PROFINET CBA / maximum2000 bayt
as user data for remote interconnections with output variables / with cyclical transfer / with PROFINET CBA / maximum2000 bayt
performance data / PROFINET CBA / HMI variables via PROFINET / acyclic
number of connectable HMI stations / for HMI variables / in the case of acyclic transmission / with PROFINET CBA3
update time / of the HMI variables / in the case of acyclic transmission / with PROFINET CBA500 ms
number of HMI variables / in the case of acyclic transmission / with PROFINET CBA / maximum200
data volume / as user data for HMI variables / in the case of acyclic transmission / with PROFINET CBA / maximum8 Kibyte
performance data / PROFINET CBA / device-internal interconnections
number of internal connections / with PROFINET CBA / maximum256
data volume / of the internal connections / with PROFINET CBA / maximum2400 bayt
performance data / PROFINET CBA / interconnections to constants
number of connections with constants / with PROFINET CBA / maximum200
data volume / as user data for interconnections with constants / with PROFINET CBA / maximum4096 bayt
performance data / PROFINET CBA / PROFIBUS proxy functionality
product function / with PROFINET CBA / PROFIBUS proxy functionalityYok
performance data / telecontrol
TCP/IPVar
product functions / management, configuration, engineering
product function / MIB supportVar
SNMP v1Var
SNMP v3Var
DCPVar
LLDPVar
requiredSTEP7 V5.5 SP2 HF1 veya üstü / STEP 7 Professional V12 (TIA Portal) veya üstü
for PROFINET CBA / requiredSIMATIC iMap V3.0 SP4 ve üstü
I&M0 - device-specific informationVar
I&M1 - higher level designation/location designationVar
product functions / diagnostics
product function / web-based diagnosticsVar
product functions / switch
product feature / switchVar
switch-managedYok
with IRT / PROFINET IO switchVar
configuration with STEP 7Var
product functions / redundancy
ring redundancyVar
redundancy managerVar
protocol / is supported / Media Redundancy Protocol (MRP)Var
product functions / security
firewall versionstateful inspection
product function / with VPN connectionIPSec
type of encryption algorithms / with VPN connectionAES-256, AES-192, AES-128, 3DES-168, DES-56
type of authentication procedure / with VPN connectionPreshared key (PSK), X.509v3 certificates
type of hashing algorithms / with VPN connectionMD5, SHA-1
number of possible connections / with VPN connection32
password protection for Web applicationsVar
ACL - IP-basedVar
ACL - IP-based for PLC/routingVar
switch-off of non-required servicesVar
blocking of communication via physical portsVar
log file for unauthorized accessYok
product functions / time
product function / SICLOCK supportVar
product function / pass on time synchronizationVar
NTPVar