product brand nameSIPLUS
transfer rate
at the 1st interface / according to PROFIBUS9,6 kbit/s... 12 Mbit/s
interfaces
number of interfaces / according to Industrial Ethernet0
at the 1st interface / according to PROFIBUS1
for power supply1
at the 1st interface / according to PROFIBUS9-pin Sub-D socket (RS485)
for power supply4-pole terminal block
supply voltage, current consumption, power loss
type of voltage / of the supply voltageDC
supply voltage / 1 / from backplane bus5 V
supply voltage / external24 V
relative positive tolerance / at DC / at 24 V20 %
relative negative tolerance / at DC / at 24 V15 %
from backplane bus / at DC / at 5 V / typical0,15 A
from external supply voltage / at DC / at 24 V / typical0,25 A
power loss [W]6,75 W
ambient conditions
during operation-25... +70 °C
during storage-40... +70 °C
during transport-40... +70 °C
installation altitude / at height above sea level / maximum5000 m
ambient condition / relating to ambient temperature - air pressure - installation altitudeTmin... Tmax 1.140 hPa... 795 hPa (-1 000 m... +2.000 m) // Tmin... (Tmax - 10 K) 795 hPa... 658 hPa (+2.000 m... +3.500 m) // Tmin... (Tmax - 20 K) 658 hPa... 540 hPa (+3.500 m... +5.000 m)
with condensation / according to IEC 60068-2-38 / maximum100 %; RH including condensation/frost (no commissioning when condensation is present), yatay installation
chemical resistance / to commercially available cooling lubricantsVar; incl. airborne diesel ve oil droplets
conformity according to EN 60721-3-3Var; Class 3B2 mold ve fungal spores (excluding fauna), Class 3B3 talep üzerine
conformity according to EN 60721-3-6Var; Class 6B2 mold, fungal ve dry rot spores (excluding fauna)
conformity according to EN 60721-3-3Var; Class 3C4 (RH < 75 %) incl. salt spray in accordance with EN 60068-2-52 (Severity 3). The supplied plug covers must remain in place on the unused interfaces during operation.
conformity according to EN 60721-3-6Var
conformity according to EN 60721-3-3Var; Class 3S4 incl. sand, dust. The supplied plug covers must remain in place over the unused interfaces during operation.
conformity according to EN 60721-3-6Var; Class 6S3 incl. sand, dust. The supplied plug covers must remain in place over the unused interfaces during operation.
coating / for equipped printed circuit board / according to EN 61086Var; Class 2 for high availability
type of coating / protection against pollution according to EN 60664-3Var; Protection of the type 1
type of test / of the coating / according to MIL-I-46058CVar; Coating discoloration during service life possible
product conformity / of the coating / Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830AVar; Conformal coating, class A
protection class IPIP20
design, dimensions and weights
module formatCompact module S7-300 single width
width40 mm
height125 mm
depth120 mm
net weight0,3 kg
product features, product functions, product components / general
per CPU / maximum4
performance data / open communication
number of possible connections / for open communication / by means of SEND/RECEIVE blocks / maximum16
as user data per connection / for open communication / by means of SEND/RECEIVE blocks / maximum240 bayt
performance data / PROFIBUS DP
DPV0Var
on DP master / operable124
of the address range of the inputs / as DP master / total2160 bayt
of the address range of the outputs / as DP master / total2160 bayt
of the address range of the inputs / per DP device244 bayt
of the address range of the outputs / per DP device244 bayt
of the address range of the diagnostic data / per DP device240 bayt
DPV0Var
of the address range of the inputs / as DP device / total240 bayt
of the address range of the outputs / as DP device / total240 bayt
performance data / S7 communication
maximum16
performance data / multi-protocol mode
without DP / maximum32
with DP / maximum28
performance data / telecontrol
TCP/IPYok
product functions / management, configuration, engineering
requiredSTEP 7 V5.1 SP2 veya üstü / STEP 7 Professional V12 (TIA Portal) veya üstü