Genel bilgiler
Ürün tipi tanımıRQ 4x120 VDC... 230 VAC/5 A NO ST
FW update possibleYok
based on6ES7132-6HD01-0BB1
usable BaseUnitsBU type B0, B1
Product function
I&M dataVar; I&M0 to I&M3
Isochronous modeYok
Mühendislik aracı
STEP 7 TIA Portal configurable/integrated from versionsee entry ID: 109746275
Operating mode
DQVar
DQ with energy-saving functionYok
PWMYok
OversamplingYok
MSOYok
Redundancy
Redundancy capabilityVar
Besleme gerilimi
Nominal değer (DC)24 V
İzin verilen aralık, alt sınır (DC)19,2 V
İzin verilen aralık, üst sınır (DC)28,8 V
Ters polarite korumasıVar
Giriş akımı
Akım tüketimi (nominal değer)55 mA; without load
Çıkış gerilimi
Rated value (AC)230 V
Güç kaybı
Güç kaybı, tipik1,5 W
Address space per module
Inputs+ 1 bayt for QI information
Outputs1 bayt
Donanım yapılandırması
Automatic encodingVar
Mechanical coding elementVar
Type of mechanical coding elementtype C
Selection of BaseUnit for connection variants
2-wire connectionBU type B1
3-wire connectionBU type B0
Dijital çıkışlar
Type of digital outputRelays
Dijital çıkış sayısı4
Current-sinkingVar
Current-sourcingVar
Digital outputs, parameterizableVar
Short-circuit protectionYok
Parallel switching of two outputs
for logic linksVar
for upratingYok
for redundant control of a loadVar
Anahtarlama frekansı
Omik yükte, maks.2 Hz
with inductive load (acc. to IEC 60947-5-1, DC13), max.0,5 Hz; provide one freewheeling diode for switching frequencies higher than 0,1 Hz
with inductive load (acc. to IEC 60947-5-1, AC15), max.0,5 Hz
Lamba yükünde, maks.2 Hz
Total current of the outputs
Current per channel, max.5 A; > +60 °C maks. continuous current per relay 3 A
Current per module, max.20 A
horizontal installation
— up to 50 °C, max.20 A
— up to 60 °C, max.16 A
vertical installation
— 40 °C’ye kadar, maks.20 A
— up to 50 °C, max.16 A; in all other mounting positions
Röle çıkışları
Röle çıkışı sayısı4
Rated supply voltage of relay coil L+ (DC)24 V
Current consumption of relays (coil current of all relays), max.40 mA
external protection for relay outputsVar, with miniature fuse maks. 6 A tripping current ve quick-response tripping characteristic
Number of operating cycles, max.7.000.000; see additional description in the manual
Switching capacity of contacts
— with inductive load, max.2 A; see additional description in the manual
— with resistive load, max.5 A; see additional description in the manual
— Thermal continuous current, max.5 A; Maks. 1.385 VA, 150 W
— Switching current, min.100 mA; 5 V DC
— Rated switching voltage (DC)24 V DC to 120 V DC
— Rated switching voltage (AC)24V AC to 230V AC
Kablo uzunluğu
Ekranlı, maks.1.000 m
Ekransız, maks.200 m
Interrupts/diagnostics/status information
Diagnostics functionVar
Substitute values connectableVar
Alarms
Diagnostic alarmVar
Diagnoses
Monitoring the supply voltageVar
Wire breakYok
Short-circuitYok
Tanılama gösterge LED’i
Monitoring of the supply voltage (PWR-LED)Var; green PWR LED
Channel status displayVar; green LED
for channel diagnosticsYok
for module diagnosticsVar; green/red DIAG LED
Potential separation channels
Kanallar arasıVar
between the channels and backplane busVar
between the channels and the power supply of the electronicsVar
Permissible potential difference
between channels and backplane bus/supply voltage240 V AC
Isolation
Isolation tested with2.500 V DC (type test)
tested with
between channels and backplane bus/supply voltage2.500 V DC
between backplane bus and supply voltage707 V DC (type test)
Standartlar, onaylar, sertifikalar
Suitable for safety functionsYok
Çalışma ortam sıcaklığı
Yatay montaj, min.-40 °C; = Tmin (incl. condensation/frost)
Yatay montaj, maks.70 °C; = Tmax; see Derating BasedOn (e.g. manual), additionally Tmax > 60 °C maks. continuous current of 3 A per relay
Dikey montaj, min.-40 °C; in all other mounting positions
Dikey montaj, maks.50 °C; in all other mounting positions
Deniz seviyesine göre çalışma yüksekliği
Installation altitude above sea level, max.3.000 m
Ambient air temperature-barometric pressure-altitudeTmin... Tmax 1.140 hPa... 795 hPa (-1 000 m... +2.000 m) // Tmin... (Tmax - 1 K/100 m) 795 hPa... 701 hPa (+2.000 m... +3.000 m)
Bağıl nem
With condensation, tested in accordance with IEC 60068-2-38, max.100 %; incl. condensation / frost permitted (no commissioning under condensation conditions)
Coolants and lubricants
— Resistant to commercially available coolants and lubricantsVar; Incl. diesel ve oil droplets in the air
Use in stationary industrial systems
— to biologically active substances according to EN 60721-3-3Var; Class 3B2 mold, fungus ve dry rot spores (with the exception of fauna); Class 3B3 talep üzerine
— to chemically active substances according to EN 60721-3-3Var; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
— to mechanically active substances according to EN 60721-3-3Var; Class 3S4 incl. sand, dust, *
— Against mechanical environmental conditions acc. to EN 60721-3-3Var; Class 3M8 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0)
Use on ships/at sea
— to biologically active substances according to EN 60721-3-6Var; Class 6B2 mold ve fungal spores (excluding fauna); Class 6B3 talep üzerine
— to chemically active substances according to EN 60721-3-6Var; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
— to mechanically active substances according to EN 60721-3-6Var; Class 6S3 incl. sand, dust; *
— Against mechanical environmental conditions acc. to EN 60721-3-6Var; Class 6M4 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0)
Usage in industrial process technology
— Against chemically active substances acc. to EN 60654-4Var; Class 3 (excluding trichlorethylene)
— Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04Var; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) ve level LB3 (oil)
Remark
— Note regarding classification of environmental conditions acc. to EN 60721, EN 60654-4 and ANSI/ISA-71.04* The supplied plug covers must remain in place over the unused interfaces during operation!
Conformal coating
Coatings for printed circuit board assemblies acc. to EN 61086Var; Class 2 for high reliability
Protection against fouling acc. to EN 60664-3Var; Type 1 protection
Military testing according to MIL-I-46058C, Amendment 7Var; Discoloration of coating possible during service life
Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830AVar; Conformal coating, Class A
Ölçüler
Genişlik20 mm
Yükseklik73 mm
Derinlik58 mm
Ağırlık
Ağırlık, yaklaşık40 g