Genel bilgiler
Ürün tipi tanımıTP1500 Comfort Outdoor
based on6AV2124-0QC13-0AX0
Display
Design of displayTFT, bonded, daylight-readable
Screen diagonal15,4 in
Display width331,2 mm
Display height207 mm
Number of colors16.777.216
Resolution (pixels)
Horizontal image resolution1.280 pixel
Vertical image resolution800 pixel
Backlighting
MTBF backlighting (at 25 °C)50.000 h
Backlight dimmableVar; LED, can be dimmed manually veya automatically
Keyboard
— Number of function keys0
— Number of function keys with LEDs0
Keys with LEDYok
System keysYok
Numeric keyboardVar; Onscreen keyboard
alphanumeric keyboardVar; Onscreen keyboard
Touch operation
Design as touch screenVar; analog, resistive
Expansions for operator control of the process
— F1...Fx0
— F1...Fx0
Direct keys (touch buttons as S7 input I/O)40
Installation type/mounting
Mounting positiondikey
Mounting in portrait format possibleVar
Mounting in landscape format possibleVar
maximum permissible angle of inclination without external ventilation35°
Besleme gerilimi
Type of supply voltageDC
Nominal değer (DC)24 V
İzin verilen aralık, alt sınır (DC)19,2 V
İzin verilen aralık, üst sınır (DC)28,8 V
Giriş akımı
Akım tüketimi (nominal değer)1,3 A
Starting current inrush I²t0,5 A²·s
Power
Active power input, typ.32 W
Processor
Processor typeX86
Storage
FlashVar
RAMVar
Memory available for user data12 MB
Type of output
Info LEDYok
Power LEDYok
Error LEDYok
BuzzerYok
SpeakerVar
Saat
Donanım saati (gerçek zamanlı)Var
Software clockYok
retentiveVar; Back-up duration typically 6 weeks
synchronizableVar
Arayüzler
Number of industrial Ethernet interfaces2
Number of RS 485 interfaces1; RS 422 / 485 combined
Number of RS 422 interfaces1
Number of RS 232 interfaces0
Number of USB interfaces2; USB 2,0
USB Mini B1; 5-pole
Number of 20 mA interfaces (TTY)0
Number of parallel interfaces0
Number of SD card slots2
With software interfacesYok
Industrial Ethernet
Industrial Ethernet status LED2
Number of ports of the integrated switch2
Protokoller
PROFINETVar
PROFINET IO protokolünü desteklerVar
IRTVar; WinCC V13 SP1 HSP veya üstü
PROFIBUSVar
EtherNet/IPVar
MPIVar
Protokoller (Ethernet)
TCP/IPVar
DHCPVar
SNMPVar
DCPVar
LLDPVar
WEB characteristics
HTTPVar
HTTPSYok
HTMLVar
XMLYok
CSSVar
Active XYok
JavaScriptVar
Java VMYok
Ortam yedekliliği
— MRPVar; WinCC V13 SP1 HSP veya üstü
Diğer protokoller
CANYok
MODBUSVar
EN 55 011’e göre radyo girişimi yayımı
Sınır sınıfı A, endüstriyel alanlarda kullanım içinVar
Sınır sınıfı B, yerleşim alanlarında kullanım içinYok
Koruma derecesi ve sınıfı
IP (at the front)IP66
IP (rear)IP20
Enclosure Type 4 at the frontVar
Enclosure Type 4x at the frontVar
Military use
conforms to MIL-STD-461GVar; CE101, CE102, CS101, CS109, CS114, CS115, CS116, CS118, RE101, RS101; requirements met for all platforms veya installations according to Table V of MIL-STD-461G
— MIL-STD-461G, RE102Var; RE102 (radiated emissions, electric field); requirements met for the following platforms veya installations according to Table V of MIL-STD-461G: all surface ship applications; submarine applications: internal to pressure hull; aircraft ve space system applications: fixed wing internal ≥ 25 meters nose to tail; ground applications: Navy fixed & Air Force
— MIL-STD-461G, RS103Var; RS103 (radiated susceptibility, electric field); suitable for maks. electric field strength of 100 V/m; requirements met for the following platforms veya installations according to Table V ve XI of MIL-STD-461G: surface ship applications: below deck; submarine applications: internal to pressure hull; aircraft applications: aircraft internal (Air Force only); all space system applications; all ground applications
Ambient conditions
Suited for indoor useVar
Suited for outdoor useVar; Powder-coated, UV resistant
Operation (vertical installation)
— For vertical installation, min.-30 °C; = Tmin
— For vertical installation, max.60 °C; (55 °C, see entry ID: 64847814)
Operation (max. tilt angle)
— At maximum tilt angle, min.-30 °C; = Tmin
— At maximum tilt angle, max.50 °C; = Tmax
Operation (vertical installation, portrait format)
— For vertical installation, min.-30 °C; = Tmin
— For vertical installation, max.50 °C; = Tmax
Operation (max. tilt angle, portrait format)
— At maximum tilt angle, min.-30 °C; = Tmin
— At maximum tilt angle, max.45 °C; = Tmax
Depolama/taşıma ortam sıcaklığı
min.-30 °C
maks.70 °C
Deniz seviyesine göre çalışma yüksekliği
Installation altitude above sea level, max.5.000 m
Ambient air temperature-barometric pressure-altitudeTmin... Tmax 1.140 hPa... 795 hPa (-1 000 m... +2.000 m) // Tmin... (Tmax - 10 K) 795 hPa... 658 hPa (+2.000 m... +3.500 m) // Tmin... (Tmax -20 K) 658 hPa... 540 hPa (+3.500 m... +5.000 m)
Bağıl nem
With condensation, tested in accordance with IEC 60068-2-38, max.100 %; RH incl. condensation/frost (no commissioning when condensation present), dikey mounting position
Coolants and lubricants
— Resistant to commercially available coolants and lubricantsVar; Incl. diesel ve oil droplets in the air
Use in stationary industrial systems
— to biologically active substances according to EN 60721-3-3Var; Class 3B2 mold, fungus ve dry rot spores (with the exception of fauna); Class 3B3 talep üzerine
— to chemically active substances according to EN 60721-3-3Var; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
— to mechanically active substances according to EN 60721-3-3Var; Class 3S4 incl. sand, dust, *
Use on ships/at sea
— to biologically active substances according to EN 60721-3-6Var; Class 6B2 mold, fungal ve dry rot spores (excluding fauna)
— to chemically active substances according to EN 60721-3-6Var; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
— to mechanically active substances according to EN 60721-3-6Var; Class 6S3 incl. sand, dust; *
Usage in industrial process technology
— Against chemically active substances acc. to EN 60654-4Var; Class 3 (excluding trichlorethylene)
— Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04Var; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) ve level LB3 (oil)
Remark
— Note regarding classification of environmental conditions acc. to EN 60721, EN 60654-4 and ANSI/ISA-71.04* The supplied plug covers must remain in place over the unused interfaces during operation!
Conformal coating
Coatings for printed circuit board assemblies acc. to EN 61086Var; Class 2 for high reliability
Protection against fouling acc. to EN 60664-3Var; Type 1 protection
Military testing according to MIL-I-46058C, Amendment 7Var; Discoloration of coating possible during service life
Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830AVar; Conformal coating, Class A
Operating systems
proprietaryYok
pre-installed operating system
Windows CEVar
Configuration
Message indicatorVar
Alarm system (incl. buffer and acknowledgment)Var
Process value display (output)Var
Process value default (input) possibleVar
Recipe managementVar
Configuration software
STEP 7 Basic (TIA Portal)Yok
STEP 7 Professional (TIA Portal)Yok
WinCC flexible CompactYok
WinCC flexible StandardYok
WinCC flexible AdvancedYok
WinCC Basic (TIA Portal)Yok
WinCC Comfort (TIA Portal)Var; WinCC V13 SP1 Update 7 + HSP veya üstü
WinCC Advanced (TIA Portal)Var; WinCC V13 SP1 Update 7 + HSP veya üstü
WinCC Professional (TIA Portal)Var; WinCC V13 SP1 Update 7 + HSP veya üstü
Online languages
Number of online/runtime languages32
Project languages
Languages per project32
Functionality under WinCC (TIA Portal)
LibrariesVar
Web browserVar
Pocket WordVar
Pocket ExcelVar
PDF ViewerVar
Media PlayerVar
SIMATIC WinCC Sm@rtServerVar
SIMATIC WinCC AuditVar
Number of Visual Basic ScriptsVar
time-controlledVar
task-controlledVar
Number of characters per info text70
Message system
Number of alarm classes32
— Number of bit messages4.000
— Number of analog messages200
S7 alarm number procedureVar
System messages HMIVar
System event, more (SIMATIC S7, SINUMERIK, SIMOTION, ... )Var
Number of characters per message80
Number of process values per message8
Acknowledgment groupsVar
Message indicatorVar
— Number of entries1.024
— Circulating bufferVar
— retentiveVar
— maintenance-freeVar
Recipe management
Number of recipes300
Data records per recipe500
Entries per data record1.000
Size of internal recipe memory2 MB
Recipe memory expandableVar
Variables
Number of variables per device2.048
Number of variables per screen400
Limit valuesVar
MultiplexingVar
StructuresVar
ArraysVar
Images
Number of configurable images500
Permanent window/defaultVar
Global imageVar
Image selection by PLCVar
Image number in the PLCVar
Image objects
Number of objects per image400
Text fieldsVar
I/O fieldsVar
Graphic I/O fields (graphics list)Var
Symbolic I/O fields (text list)Var
Date/time fieldsVar
SwitchesVar
ButtonsVar
Graphic displayVar
IconsVar
Geometric objectsVar
Complex image objects
Number of complex objects per screen20
Alarm viewVar
Trend viewVar
User viewVar
Status/controlVar
Sm@rtClient viewVar
Recipe viewVar
f(x) trend viewVar
System diagnostics viewVar
Media PlayerVar
IP camera displayVar; Webcam type see FAQs
Bar graphsVar
SlidersVar
Pointer instrumentsVar
Analog/digital clockVar
Lists
Number of text lists per project500
Number of entries per text list500
Number of graphics lists per project500
Number of entries per graphics list500
Archiving
Number of archives per device50
Number of entries per archive20.000
Message archiveVar
Process value archiveVar
— Sequential archiveVar
— Short-term archiveVar
— Memory cardVar
— USB memoryVar
— EthernetVar
— CSVVar
— TXTVar
— RDBVar
Security
Number of user groups50
Number of user rights32
Kullanıcı sayısı50
Password export/importVar
SIMATIC LogonVar
Logging through printer
AlarmsVar
Report (shift log)Var
HardcopyVar
Electronic print to fileVar; PDF, HTML
Character sets
— US EnglishVar
Transfer (upload/download)
MPI/PROFIBUS DPVar
USBVar
EthernetVar
using external storage mediumVar; Backup/restore
Process coupling
S7-1200Var
S7-1500Var
S7-200Var
S7-300/400Var
LOGO!Var
WinACVar
SINUMERIKVar; with SINUMERIK option package
SIMOTIONVar
Allen Bradley (EtherNet/IP)Var
Allen Bradley (DF1)Var
Mitsubishi (MC TCP/IP)Var
Mitsubishi (FX)Var
OMRON (FINS TCP)Yok
OMRON (Host Link)Var
Modicon (Modbus TCP/IP)Var
Modicon (Modbus RTU)Var
OPC UA ClientVar
OPC UA sunucusuVar
Service tools/configuration aids
Backup/Restore manuallyVar
Backup/Restore automaticallyVar
SimulationVar
Device switchoverVar
Peripherals/Options
PrinterVar
SIMATIC HMI MM memory card: Multi Media CardVar
SIMATIC HMI SD memory card: Secure Digital memory cardVar
SIMATIC HMI CF memory card Compact Flash CardYok
USB memoryVar; e.g. USB RFID reader, see FAQ entry ID: 99808171
SIMATIC IPC USB Flashdrive (USB stick)Var
SIMATIC HMI USB stickVar
Network cameraVar; See FAQ Entry ID: 62383298 ve entry ID: 65647473
Accessories
extension moduleOptional e.g. USB RFID reader, see FAQ entry ID: 99808171
Further accessories are availableVar; Mounting clips ve 2-pin power supply connector
Mechanics/material
PlasticYok
AluminumVar; Powder-coated, UV resistant
Stainless steelYok
Ölçüler
Width of the housing front415 mm
Height of housing front310 mm
Mounting cutout, width396 mm
Mounting cutout, height291 mm
mounting depth73,2 mm
Ağırlık
Weight (without packaging)4 kg
Weight (with packaging)6,2 kg
Other
Note:Power, quantity structure ve performance correspond to a standard 12" Comfort Panel