
Siemens
1EE1122-..A00-...4
MFR #1EE1122-..A00-...4
SKU #YLS3FGFZLYE3EV8
Web sitemizde size daha iyi bir deneyim sunmak için çerezler kullanıyoruz. Çerezler, site performansını artırmak, içerikleri kişiselleştirmek ve trafiği analiz etmek için kullanılır.

Fotoğraf, ürünün gerçek halini yansıtmayabilir. Tüm detaylar için ürünün adına ve özelliklerine bakınız.
UP 227 - KNX Room Control Unit, i-system. Multifunctional display-/control panel for KNX with Dot-Matrix LCD display 96 x 128 pixels 8 capacitive touch buttons for horizontal operation For the display and control of at least 10 adjustable room control functions: Switching toggle/On/Off, Dimming, Door bell function On/Off, Solar protection control; send 1 Byte/2 Byte value; display 1 Bit/1 Byte/2 Byte value; Forced control; display text messages; warning and alarm messaging; recall and save scenes; warning and alarm messaging Room control functions lockable via KNX-bus Green/red LED as orientation light, as status indication, as a response to pressing a button respectively to the signalling of alarm reports A signaler for acoustical alarm reports respectively as a status of the touch operation Integrated room temperature sensor Evaluation and weighting of an external inside temperature sensor Room temperature control configurable as two-step control and/or continuous control, for exclusive heating operation, exclusive cooling operation or heating and cooling operation Selectable operating modes over the KNX: Comfort, Pre-comfort, Energy-savings and protection Local indication Of the active operating modes or automatic- respectively manual mode Inside temperature or outside temperature Heating or cooling mode Dew point alarm Open window Local switching between Manual- and automatic mode Comfort, pre-comfort, energy-saving- and protection mode Adjustable time-limited extension of the comfort mode Adjustable room temperature setpoint shifting for comfort mode Via KNX set basic setpoint value of the room temperature for comfort mode An outside temperature based temperature setpoint value tracing in the cooling operation Adjustable dead zone between the heating setpoint value and the cooling setpoint value for comfort mode Transmission of controller output(s) either as On/Off switching commands or as control commands in the range 0...100 % Local display of the manually selected fan rotational speed respectively of the automatic adjustment of the fan rotational speed Adjustable fan rotational speed respectively automatic adjustment of the fan rotational speed on the controller Weekly schedule programme for controller- operating modes, automatic mode and at the least 8 room control functions At the least 40 schedule tasks and Display and set of the date and time User control of LCD background lighting and Background color Display system settings and room temperature controller in the languages: German, English, French, Italian od Spanish User setting of at least 3 operating languages also Integrated bus coupling unit, bus connection via bus terminal possible Flush mounted device for the mounting in an flush wall box Ø 60 mm, for fixing on the mounting plate AQR2500NF via lateral springs (separately specified)
UP 227 - KNX Room Control Unit, i-system. Multifunctional display-/control panel for KNX with Dot-Matrix LCD display 96 x 128 pixels 8 capacitive touch buttons for horizontal operation For the display and control of at least 10 adjustable room control functions: Switching toggle/On/Off, Dimming, Door bell function On/Off, Solar protection control; send 1 Byte/2 Byte value; display 1 Bit/1 Byte/2 Byte value; Forced control; display text messages; warning and alarm messaging; recall and save scenes; warning and alarm messaging Room control functions lockable via KNX-bus Green/red LED as orientation light, as status indication, as a response to pressing a button respectively to the signalling of alarm reports A signaler for acoustical alarm reports respectively as a status of the touch operation Integrated room temperature sensor Evaluation and weighting of an external inside temperature sensor Room temperature control configurable as two-step control and/or continuous control, for exclusive heating operation, exclusive cooling operation or heating and cooling operation Selectable operating modes over the KNX: Comfort, Pre-comfort, Energy-savings and protection Local indication Of the active operating modes or automatic- respectively manual mode Inside temperature or outside temperature Heating or cooling mode Dew point alarm Open window Local switching between Manual- and automatic mode Comfort, pre-comfort, energy-saving- and protection mode Adjustable time-limited extension of the comfort mode Adjustable room temperature setpoint shifting for comfort mode Via KNX set basic setpoint value of the room temperature for comfort mode An outside temperature based temperature setpoint value tracing in the cooling operation Adjustable dead zone between the heating setpoint value and the cooling setpoint value for comfort mode Transmission of controller output(s) either as On/Off switching commands or as control commands in the range 0...100 % Local display of the manually selected fan rotational speed respectively of the automatic adjustment of the fan rotational speed Adjustable fan rotational speed respectively automatic adjustment of the fan rotational speed on the controller Weekly schedule programme for controller- operating modes, automatic mode and at the least 8 room control functions At the least 40 schedule tasks and Display and set of the date and time User control of LCD background lighting and Background color Display system settings and room temperature controller in the languages: German, English, French, Italian od Spanish User setting of at least 3 operating languages also Integrated bus coupling unit, bus connection via bus terminal possible Flush mounted device for the mounting in an flush wall box Ø 60 mm, for fixing on the mounting plate AQR2500NF via lateral springs (separately specified)

Siemens
MFR #1EE1122-..A00-...4
SKU #YLS3FGFZLYE3EV8

Siemens
MFR #1EE1124-..A00-...4
SKU #YLSKZIN1GEIPRVP

Siemens
MFR #1EE1142-..A00-...4
SKU #YLSUX3MNEZEJGPU

Siemens
MFR #1EE1144-..A00-...4
SKU #YLSD9GON9QOYBAE

Siemens
MFR #1EE1322-....0-...4
SKU #YLSSAVZE8P7OOP6

Siemens
MFR #1EE1322-...00-1..2
SKU #YLSY69IQB2JXAXJ

Siemens
MFR #1EE1322-..A00-...4
SKU #YLSH1E6AJR6XWJF

Siemens
MFR #1EE1324-....0-...4
SKU #YLS8GBB9BXAF83

Siemens
MFR #1EE1324-...00-1..2
SKU #YLSLOS6I1BDXR58

Siemens
MFR #1EE1324-..A00-...4
SKU #YLSE0T3LUEU0CI

SMC
MFR #CDJ2L16-125Z-B
SKU #YLS5V0RW2VJJR1A

SMC
MFR #AL30-03-8-A
SKU #YLS6GDABZE4BN7A

SMC
MFR #ZCUKQ25-50D
SKU #YLSQ684QXTNN958

SMC
MFR #AC20A-01G-V-1-B FR/L COMBO MODULAR
SKU #YLSSMWXCWLO2KA6

SMC
MFR #MXS-AS16L
SKU #YLSAP0XXFGFSWY6

SMC
MFR #MY1M20-200AH
SKU #YLSIZ8K8N4KBPBQ

SMC
MFR #AR30-N02E-1Z-B
SKU #YLSYFNHADE6GRKV

Baldor
MFR #VM8001-5
SKU #YLS3TOWVXWW0DHP

SMC
MFR #MGPL25TN-200BZ-XC9
SKU #YLSPBI637NOCN0Y

SMC
MFR #VQC2101R-51
SKU #YLSSEY6NT0YLZ8G
Siemens 5WG1227-2AB11 fiyatSiemens 5WG1227-2AB11 teklif alSiemens 5WG1227-2AB11 satın al5WG1227-2AB11 fiyat5WG1227-2AB11 stok durumuSiemens yedek parçaSiemens 5WG1227-2AB11 muadilSiemens 5WG1227-2AB11 teknik özellikler