SIRIUS safety röle Safety-oriented Speed monitoring 110-240 V AC/DC, 45 mm overall genişlik Spring-type klemens EC instantaneous: 2 NO EC delayed: 0 SC: 2 electrical Auto-start/manuel başlatma temel cihaz Maximum achievable PL according to EN 13849-1: e Maximum achievable SIL according to IEC 61508: 3

SiemensMFR # 3TK2810-1KA42SKU # CEY-8EF3B038DE7F
product brand nameSIRIUS
product designationSpeed monitor
design of the productstandstill ve speed monitoring
product type designation3TK28
automatic startVar
light barrier monitoringYok

Ürün Hakkında

SIRIUS safety röle Safety-oriented Speed monitoring 110-240 V AC/DC, 45 mm overall genişlik Spring-type klemens EC instantaneous: 2 NO EC delayed: 0 SC: 2 electrical Auto-start/manuel başlatma temel cihaz Maximum achievable PL according to EN 13849-1: e Maximum achievable SIL according to IEC 61508: 3

Siemens 3TK2810-1KA42

  • Orijinal ve sertifikalı Siemens ürünü
  • Dünya genelinde tedarik ağıyla hızlı temin
  • Teknik ekibimizden ürün seçimi ve uyumluluk desteği
  • Muadil ve alternatif ürün önerisi
  • Talebinize özel fiyat teklifi ve teslim süresi

Teknik Özellikler

product brand nameSIRIUS
product designationSpeed monitor
design of the productstandstill ve speed monitoring
product type designation3TK28
Product Function
automatic startVar
light barrier monitoringYok
standstill monitoringVar
protective door monitoringVar
magnetically operated switch monitoring NC-NOYok
magnetically operated switch monitoring NC-NCYok
rotation speed monitoringVar
laser scanner monitoringYok
light array monitoringYok
EMERGENCY OFF functionVar
monitored start-upVar
pressure-sensitive mat monitoringYok
product feature cross-circuit-proofVar
suitability for interaction press controlYok
monitoring of floating sensorsVar
monitoring of non-floating sensorsYok
position switch monitoringVar
EMERGENCY-OFF circuit monitoringYok
valve monitoringYok
opto-electronic protection device monitoringYok
tactile sensor monitoringYok
magnetically operated switch monitoringYok
proximity switch monitoringVar
safety-related circuitsVar
General technical data
certificate of suitability UL approvalVar
insulation voltage rated value300 V
surge voltage resistance rated value4.000 V
of the enclosureIP20
shock resistance8 g / 10 ms
vibration resistance according to IEC 60068-2-610... 55 Hz: 0,35 mm
electrical endurance (operating cycles) typical100.000
Substance Prohibitance (day/month/year)05/01/2012
SVHC substance nameLead monoxide (lead oxide) CAS-Yok. 1317-36-8
Net Weight414 g
Ambient conditions
installation altitude at height above sea level maximum2.000 m
noteinstallation altitude: 5000 m with derating
during operation0... 60 °C; from an operating altitude > 2000 m, the maximum permissible temperature is reduced by 0,5 °C / 100 m
during storage-20... +70 °C
relative humidity during operation10... 95 %
air pressure according to SN 3120590... 106 kPa
Electromagnetic compatibility
installation environment regarding EMCThis product is suitable for Class A environments only. In household environments, this device can cause unwanted radio interference. The user is required to implement appropriate measures in this case.
EMC emitted interferenceEN 60947-5-1
Safety related data
product function suitable for safety functionVar
stop category according to IEC 60204-10
IEC 62061
SIL Claim Limit (subsystem) according to EN 620613
Safety Integrity Level (SIL) according to IEC 62061SIL 3
PFHD with high demand rate according to IEC 620613.4E-9 1/h
ISO 13849
category according to EN ISO 13849-14
according to ISO 13849-1PL e
for delayed release circuit according to ISO 13849-1e
IEC 61508
according to IEC 615083
for delayed release circuit according to IEC 61508SIL3
safety device type according to IEC 61508-2Type B
hardware fault tolerance according to IEC 615081
T1 value for proof test interval or service life according to IEC 6150820 a
Electrical Safety
touch protection against electrical shockfinger-safe
Short-circuit protection
design of the fuse link for short-circuit protection of the NO contacts of the relay outputs requiredgL/gG: 4 A
Inputs
cascading input/functional switchingYok
feedback inputVar
start inputVar
1-channel or 2-channel0
2-channel3
Outputs
— for signaling function instantaneous contact0
— for signaling function delayed switching0
— safety-related instantaneous contact0
— safety-related delayed switching0
— for signaling function instantaneous contact0
— for signaling function delayed switching0
— safety-related instantaneous contact1
— safety-related delayed switching1
mechanical service life (operating cycles) typical50.000.000
thermal current of the switching element with contacts maximum5 A
— delayed switching1
— instantaneous contact1
— delayed switching0
— instantaneous contact0
for signaling function at DC-13 at 24 V0,02 A
at 24 V2 A
at 115 V2 A
at 24 V3 A
at 230 V3 A
at 24 V3 A
at 115 V3 A
at 230 V2 A
type of switching outputoptionally PNP veya NPN
Encoder
encoder signal evaluationtwo signal tracks her biri with inverted signals
type of signal level of the encoderoptionally TTL, HTL veya sin/cos (Ua = 1Vss)
type of failure response of the encoderhigh-resistance
Proximity switch
type of voltage of the supply voltage of proximity switchesDC
supply voltage of proximity switches24 V; provided by the device
current consumption of proximity switches maximum30 mA
input voltage for proximity switch minimum10 V
pulse duration of proximity switches minimum75 µs
interpulse period of proximity switches minimum75 µs
adjustment range of signal frequency of proximity switches1 Hz... 2 kHz
measuring precision+-2 %
switching hysteresis6,25 %
Control circuit/ Control
type of voltage of the control supply voltageAC/DC
at 50 Hz110... 240 V
at 60 Hz110... 240 V
1 rated value50 Hz
2 rated value60 Hz
control supply voltage 1 at DC110... 240 V
initial value0,8
full-scale value1,1
at 50 Hz0,8... 1,1
at 60 Hz0,8... 1,1
Installation/ mounting/ dimensions
mounting positionany
fastening methodscrew ve snap-on mounting
height107,7 mm
width45 mm
depth124,3 mm
Connections/ Terminals
type of electrical connectionspring-loaded terminals
solid1x (0,5... 4 mm²)
finely stranded with core end processing2 x (0,25... 1,5 mm²)
finely stranded without core end processing2x (0,25... 1,5 mm²)
for AWG cables solid2x (24... 16)
for AWG cables stranded2x (20... 16)
solid0,25... 1,5 mm²
finely stranded with core end processing0,25... 1,5 mm²
finely stranded without core end processing0,25... 1,5 mm²
solid24... 16
stranded24... 16

İlgili Ürünler

3MV8100-0MB00
Siemens 3MV8100-0MB00
Detayları Gör

Siemens

3MV8100-0MB00

MFR #3MV8100-0MB00

SKU #YLSTQVYRHTPPWXE

3MV8100-0MC00
Siemens 3MV8100-0MC00
Detayları Gör

Siemens

3MV8100-0MC00

MFR #3MV8100-0MC00

SKU #YLSNDRLO7GD0JC3

3MV8100-0MD00
Siemens 3MV8100-0MD00
Detayları Gör

Siemens

3MV8100-0MD00

MFR #3MV8100-0MD00

SKU #YLSLDR7SAMNEI7

3MV8100-0ME00
Siemens 3MV8100-0ME00
Detayları Gör

Siemens

3MV8100-0ME00

MFR #3MV8100-0ME00

SKU #YLSQYIXF5Z6DOGW

3MV8100-0MF00
Siemens 3MV8100-0MF00
Detayları Gör

Siemens

3MV8100-0MF00

MFR #3MV8100-0MF00

SKU #YLSE4VVERJVVVFH

3MV8100-0MG00
Siemens 3MV8100-0MG00
Detayları Gör

Siemens

3MV8100-0MG00

MFR #3MV8100-0MG00

SKU #YLSI4OKULAP3QK

3MV8100-0MH00
Siemens 3MV8100-0MH00
Detayları Gör

Siemens

3MV8100-0MH00

MFR #3MV8100-0MH00

SKU #YLSCUEFEDHRZRUJ

3MV8100-0MJ00
Siemens 3MV8100-0MJ00
Detayları Gör

Siemens

3MV8100-0MJ00

MFR #3MV8100-0MJ00

SKU #YLSMBKZVBRAS5T

3MV8100-0MK00
Siemens 3MV8100-0MK00
Detayları Gör

Siemens

3MV8100-0MK00

MFR #3MV8100-0MK00

SKU #YLS3JCVHPICJ2VL

3MV8100-0ML00
Siemens 3MV8100-0ML00
Detayları Gör

Siemens

3MV8100-0ML00

MFR #3MV8100-0ML00

SKU #YLSMFZC3SXLCXHP

Öne Çıkan Ürünler

NCDMC150-0600-X155US
SMC NCDMC150-0600-X155US
Detayları Gör

SMC

NCDMC150-0600-X155US

MFR #NCDMC150-0600-X155US

SKU #YLS8ICKGSKYC93L

MXS-AS16L
SMC MXS-AS16L
Detayları Gör

SMC

MXS-AS16L

MFR #MXS-AS16L

SKU #YLSAP0XXFGFSWY6

BM3615T W/ 2-1/4" LONG SHAFT
Baldor BM3615T W/  2-1/4" LONG SHAFT
Detayları Gör

Baldor

BM3615T W/ 2-1/4" LONG SHAFT

MFR #BM3615T W/ 2-1/4" LONG SHAFT

SKU #YLSUV0OKQIKNTRJ

EH22512
Danfoss Aeroquip LLC EH22512
Detayları Gör

Danfoss Aeroquip LLC

EH22512

MFR #EH22512

SKU #YLSRZ91UGVO64DG

AR30-N02E-1Z-B
SMC AR30-N02E-1Z-B
Detayları Gör

SMC

AR30-N02E-1Z-B

MFR #AR30-N02E-1Z-B

SKU #YLSYFNHADE6GRKV

MTS32-150M
SMC MTS32-150M
Detayları Gör

SMC

MTS32-150M

MFR #MTS32-150M

SKU #YLSSJCSBTRLX2P7

CDJ2L16-125Z-B
SMC CDJ2L16-125Z-B
Detayları Gör

SMC

CDJ2L16-125Z-B

MFR #CDJ2L16-125Z-B

SKU #YLS5V0RW2VJJR1A

CM2B40-75Z
SMC CM2B40-75Z
Detayları Gör

SMC

CM2B40-75Z

MFR #CM2B40-75Z

SKU #YLSOGLJ512KWTEJ

İlgili Aramalar

Siemens 3TK2810-1KA42 fiyatSiemens 3TK2810-1KA42 teklif alSiemens 3TK2810-1KA42 satın al3TK2810-1KA42 fiyat3TK2810-1KA42 stok durumuSiemens yedek parçaSiemens 3TK2810-1KA42 muadilSiemens 3TK2810-1KA42 teknik özellikler