Çerez Kullanımı

Web sitemizde size daha iyi bir deneyim sunmak için çerezler kullanıyoruz. Çerezler, site performansını artırmak, içerikleri kişiselleştirmek ve trafiği analiz etmek için kullanılır.

Siemens 3TF6844-0CF7

Fotoğraf, ürünün gerçek halini yansıtmayabilir. Tüm detaylar için ürünün adına ve özelliklerine bakınız.

Siemens 3TF6844-0CF7

vacuum contactor AC-3e/AC-3 630 A, 335 kW / 400 V, Ue 690 V, 3-pole, Uc: 110-132 V AC(50/60 Hz) drive: conventional auxiliary contacts 4 NO + 4 NC main circuit: busbar control and auxiliary circuit: screw terminal

SiemensMFR # 3TF6844-0CF7SKU # CEY-937FC780BCC8
product designationVacuum contactor
product type designation3TF6
size of contactor14
function module for communicationYok
auxiliary switchYok
of main circuit rated value8 kV

Ürün Hakkında

vacuum contactor AC-3e/AC-3 630 A, 335 kW / 400 V, Ue 690 V, 3-pole, Uc: 110-132 V AC(50/60 Hz) drive: conventional auxiliary contacts 4 NO + 4 NC main circuit: busbar control and auxiliary circuit: screw terminal

Siemens 3TF6844-0CF7

  • Orijinal ve sertifikalı Siemens ürünü
  • Dünya genelinde tedarik ağıyla hızlı temin
  • Teknik ekibimizden ürün seçimi ve uyumluluk desteği
  • Muadil ve alternatif ürün önerisi
  • Talebinize özel fiyat teklifi ve teslim süresi

Teknik Özellikler

product designationVacuum contactor
product type designation3TF6
General technical data
size of contactor14
function module for communicationYok
auxiliary switchYok
of main circuit with degree of pollution 3 rated value1.000 V
of auxiliary circuit with degree of pollution 3 rated value690 V
of main circuit rated value8 kV
of auxiliary circuit rated value6 kV
in networks with grounded star point between auxiliary and auxiliary circuit300 V
in networks with grounded star point between main and auxiliary circuit500 V
at AC8,1 g / 5 ms, 4,7 g / 10 ms
at AC12,8 g / 5 ms, 7,4 g / 10 ms
of contactor typical5.000.000
reference code according to IEC 81346-2Q
Substance Prohibitance (day/month/year)03/01/2017
SVHC substance nameLead CAS-Yok. 7439-92-1 Lead monoxide (lead oxide) CAS-Yok. 1317-36-8 2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-Yok. 71868-10-5 Melamine CAS-Yok. 108-78-1
Net Weight19,341 kg
Ambient conditions
installation altitude at height above sea level maximum2.000 m
during operation-25... +55 °C
during storage-55... +80 °C
relative humidity minimum10 %
relative humidity during operation10... 95 %
relative humidity at 55 °C according to IEC 60068-2-30 maximum95 %
Main circuit
number of poles for main current circuit3
number of NO contacts for main contacts3
number of NC contacts for main contacts0
type of voltage for main current circuitAC
at AC-3 rated value maximum690 V
at AC-3e rated value maximum690 V
— up to 690 V at ambient temperature 40 °C rated value700 A
— up to 690 V at ambient temperature 55 °C rated value630 A
— at 400 V rated value630 A
— at 500 V rated value630 A
— at 690 V rated value630 A
— at 400 V rated value552 A
— at 500 V rated value552 A
— at 690 V rated value552 A
at AC-4 at 400 V rated value610 A
— up to 500 V for current peak value n=20 rated value513 A
— up to 690 V for current peak value n=20 rated value513 A
— up to 400 V for current peak value n=30 rated value342 A
— up to 500 V for current peak value n=30 rated value342 A
— up to 690 V for current peak value n=30 rated value342 A
at 40 °C minimum permissible480 mm²
at 400 V rated value300 A
at 690 V rated value300 A
— at 230 V rated value200 kW
— at 400 V rated value355 kW
— at 500 V rated value400 kW
— at 690 V rated value600 kW
— at 230 V rated value160 kW
— at 400 V rated value315 kW
— at 690 V rated value560 kW
up to 400 V for current peak value n=20 rated value338 kVA
up to 690 V for current peak value n=20 rated value586 kVA
up to 400 V for current peak value n=30 rated value226 kVA
up to 690 V for current peak value n=30 rated value390 kVA
thermal short-time current limited to 10 s5.040 A
power loss [W] at AC-3 at 400 V for rated value of the operational current per conductor45 W
power loss [W] at AC-3e at 400 V for rated value of the operational current per conductor35 W
no-load switching frequency at AC500 1/h
at AC-1 maximum500 1/h
— at 400 V maximum500 1/h
— at 690 V maximum500 1/h
at AC-2 at AC-3 maximum200 1/h
at AC-2 at AC-3e maximum200 1/h
Control circuit/ Control
type of voltage of the control supply voltageAC
at 50 Hz rated value110... 132 V
at 60 Hz rated value110... 132 V
at 50 Hz0,8... 1,1
at 60 Hz0,8... 1,1
inrush current peak18 A
duration of inrush current peak300 µs
pickup current mean value7,7 mA
pickup current peak9 A
duration of pickup current150.000 µs
holding current mean value64 mA
— at 50 Hz850 V·A
— at 60 Hz850 V·A
— at 60 Hz950 V·A
— at 50 Hz950 V·A
at 50 Hz1
at 60 Hz1
— at 50 Hz7 V·A
— at 60 Hz7 V·A
— at 50 Hz8 V·A
— at 60 Hz8 V·A
at 50 Hz0,4
at 60 Hz0,4
at AC70... 120 ms
at AC50... 130 ms
arcing time10... 15 ms
control version of the switch operating mechanismStandard A1 - A2
Auxiliary circuit
attachable4
instantaneous contact4
attachable4
instantaneous contact4
operational current at AC-12 maximum10 A
at 230 V rated value5,6 A
at 400 V rated value3,6 A
at 500 V rated value2,5 A
at 690 V rated value2,3 A
operational current at DC-12 at 440 V rated value0,33 A
at 24 V rated value10 A
at 48 V rated value10 A
at 110 V rated value3,2 A
at 125 V rated value2,5 A
at 220 V rated value0,9 A
at 600 V rated value0,22 A
at 24 V rated value10 A
at 48 V rated value5 A
at 110 V rated value1,14 A
at 125 V rated value0,98 A
at 220 V rated value0,48 A
at 600 V rated value0,07 A
contact reliability of auxiliary contactsone incorrect switching operation of 100 million switching operations (17 V, 5 mA)
UL/CSA ratings
at 480 V rated value630 A
at 600 V rated value630 A
— at 200/208 V rated value231 hp
— at 220/230 V rated value266 hp
— at 460/480 V rated value530 hp
— at 575/600 V rated value664 hp
contact rating of auxiliary contacts according to ULA600 / Q600
Short-circuit protection
— with type of coordination 1 requiredgG: 1000 A (690 V, 100 kA)
— with type of coordination 2 requiredgG: 500 A (690 V, 100 kA), aM: 630 A (690 V, 50 kA), BS88: 500 A (415 V, 50 kA)
for short-circuit protection of the auxiliary switch requiredfuse gG: 10 A
Installation/ mounting/ dimensions
mounting positionwith dikey mounting surface +/-90° rotatable, with dikey mounting surface +/- 22,5° tiltable to the front ve back
fastening method side-by-side mountingVar
fastening methodscrew fixing
height276 mm
width230 mm
depth237 mm
— forwards20 mm
— upwards10 mm
— downwards10 mm
— at the side10 mm
— forwards20 mm
— upwards10 mm
— at the side10 mm
— downwards10 mm
— forwards20 mm
— upwards10 mm
— downwards10 mm
— at the side10 mm
Connections/ Terminals
for main current circuitConnection bar
for auxiliary and control circuitscrew-type terminals
at contactor for auxiliary contactsScrew-type terminals
width of connection bar30 mm
thickness of connection bar6 mm
diameter of holes11 mm
number of holes1
stranded70... 240 mm²
finely stranded with core end processing50... 240 mm²
finely stranded with core end processing240... 50 mm²
solid or stranded0,5... 2,5 mm²
finely stranded with core end processing0,5... 2,5 mm²
— solid2x (0,5... 1,0 mm²), 2x (1,0... 2,5 mm²)
— finely stranded with core end processing2x (0,5... 1,0 mm²), 2x (0,75... 2,5 mm²)
for AWG cables for auxiliary contacts2x (18... 12)
AWG number as coded connectable conductor cross section for main contacts500
AWG number as coded connectable conductor cross section for auxiliary contacts18... 12
Safety related data
mirror contact according to IEC 60947-4-1Var; One NC contact her biri must be connected in series for the right ve left auxiliary switch block respectively
positively driven operation according to IEC 60947-5-1Yok
suitable for safety functionVar
service life maximum20 a
test wear-related service life necessaryVar
with low demand rate according to SN 3192040 %
with high demand rate according to SN 3192073 %
B10 value with high demand rate according to SN 319201.000.000
failure rate [FIT] with low demand rate according to SN 31920100 FIT
ISO 13849
device type according to ISO 13849-13
overdimensioning according to ISO 13849-2 necessaryVar
IEC 61508
safety device type according to IEC 61508-2Type A
Electrical Safety
protection class IP on the front according to IEC 60529IP00; IP20 with cover
touch protection on the front according to IEC 60529finger-safe, for dikey contact from the front with cover

Aksesuarlar 4

Siemens 3TF6844-0CF7 motorla birlikte kullanılabilen, ayrı olarak tedarik edilen orijinal aksesuarlar aşağıda listelenmiştir. Koda tıklayarak aksesuarın sayfasına ve uyumlu diğer motorlara ulaşabilirsiniz.

Parça noAçıklamaUyumlu motor
3TX7572-3GAksesuar · Surge suppressor · varistors
3TX7572-3JAksesuar · Surge suppressor · varistors
3TX7686-0AAksesuar · Terminal covers · terminal covers
3TX7696-0AAksesuar · Terminal covers · terminal covers

İlgili Ürünler

1EE1122-..A00-...4
Siemens 1EE1122-..A00-...4
Detayları Gör

Siemens

1EE1122-..A00-...4

MFR #1EE1122-..A00-...4

SKU #YLS3FGFZLYE3EV8

1EE1124-..A00-...4
Siemens 1EE1124-..A00-...4
Detayları Gör

Siemens

1EE1124-..A00-...4

MFR #1EE1124-..A00-...4

SKU #YLSKZIN1GEIPRVP

1EE1142-..A00-...4
Siemens 1EE1142-..A00-...4
Detayları Gör

Siemens

1EE1142-..A00-...4

MFR #1EE1142-..A00-...4

SKU #YLSUX3MNEZEJGPU

1EE1144-..A00-...4
Siemens 1EE1144-..A00-...4
Detayları Gör

Siemens

1EE1144-..A00-...4

MFR #1EE1144-..A00-...4

SKU #YLSD9GON9QOYBAE

1EE1322-....0-...4
Siemens 1EE1322-....0-...4
Detayları Gör

Siemens

1EE1322-....0-...4

MFR #1EE1322-....0-...4

SKU #YLSSAVZE8P7OOP6

1EE1322-...00-1..2
Siemens 1EE1322-...00-1..2
Detayları Gör

Siemens

1EE1322-...00-1..2

MFR #1EE1322-...00-1..2

SKU #YLSY69IQB2JXAXJ

1EE1322-..A00-...4
Siemens 1EE1322-..A00-...4
Detayları Gör

Siemens

1EE1322-..A00-...4

MFR #1EE1322-..A00-...4

SKU #YLSH1E6AJR6XWJF

1EE1324-....0-...4
Siemens 1EE1324-....0-...4
Detayları Gör

Siemens

1EE1324-....0-...4

MFR #1EE1324-....0-...4

SKU #YLS8GBB9BXAF83

1EE1324-...00-1..2
Siemens 1EE1324-...00-1..2
Detayları Gör

Siemens

1EE1324-...00-1..2

MFR #1EE1324-...00-1..2

SKU #YLSLOS6I1BDXR58

1EE1324-..A00-...4
Siemens 1EE1324-..A00-...4
Detayları Gör

Siemens

1EE1324-..A00-...4

MFR #1EE1324-..A00-...4

SKU #YLSE0T3LUEU0CI

Öne Çıkan Ürünler

SY5420-5DZ-01
SMC SY5420-5DZ-01
Detayları Gör

SMC

SY5420-5DZ-01

MFR #SY5420-5DZ-01

SKU #YLSQW9MERWL033X

NCDJ2L10-300-B
SMC NCDJ2L10-300-B
Detayları Gör

SMC

NCDJ2L10-300-B

MFR #NCDJ2L10-300-B

SKU #YLSRRDWPL50RWQ2

MDBB63-100Z
SMC MDBB63-100Z
Detayları Gör

SMC

MDBB63-100Z

MFR #MDBB63-100Z

SKU #YLSNBPQBGLI90UX

VQC2101R-51
SMC VQC2101R-51
Detayları Gör

SMC

VQC2101R-51

MFR #VQC2101R-51

SKU #YLSSEY6NT0YLZ8G

EH22512
Danfoss Aeroquip LLC EH22512
Detayları Gör

Danfoss Aeroquip LLC

EH22512

MFR #EH22512

SKU #YLSRZ91UGVO64DG

MTS32-150M
SMC MTS32-150M
Detayları Gör

SMC

MTS32-150M

MFR #MTS32-150M

SKU #YLSSJCSBTRLX2P7

CM2B40-75Z
SMC CM2B40-75Z
Detayları Gör

SMC

CM2B40-75Z

MFR #CM2B40-75Z

SKU #YLSOGLJ512KWTEJ

AL30-03-8-A
SMC AL30-03-8-A
Detayları Gör

SMC

AL30-03-8-A

MFR #AL30-03-8-A

SKU #YLS6GDABZE4BN7A

MY1M20-200AH
SMC MY1M20-200AH
Detayları Gör

SMC

MY1M20-200AH

MFR #MY1M20-200AH

SKU #YLSIZ8K8N4KBPBQ

AR30-N02E-1Z-B
SMC AR30-N02E-1Z-B
Detayları Gör

SMC

AR30-N02E-1Z-B

MFR #AR30-N02E-1Z-B

SKU #YLSYFNHADE6GRKV

İlgili Aramalar

Siemens 3TF6844-0CF7 fiyatSiemens 3TF6844-0CF7 teklif alSiemens 3TF6844-0CF7 satın al3TF6844-0CF7 fiyat3TF6844-0CF7 stok durumuSiemens yedek parçaSiemens 3TF6844-0CF7 muadilSiemens 3TF6844-0CF7 teknik özellikler