product brand nameSIRIUS
product categoryHybrid switching devices
product designationSoft starter
product type designation3RW52
of standard HMI module usable3RW5980-0HS00
of high feature HMI module usable3RW5980-0HF00
of communication module PROFINET standard usable3RW5980-0CS00
of communication module PROFIBUS usable3RW5980-0CP00
of communication module Modbus TCP usable3RW5980-0CT00
of communication module Modbus RTU usable3RW5980-0CR00
of communication module Ethernet/IP3RW5980-0CE00
of circuit breaker usable at 400 V3RV2032-4EA10; Type of coordination 1, Iq = 65 kA, CLASS 10
of circuit breaker usable at 500 V3RV2032-4EA10; Type of coordination 1, Iq = 15 kA, CLASS 10
of circuit breaker usable at 400 V at inside-delta circuit3RV2032-4VA10; Type of coordination 1, Iq = 65 kA, CLASS 10
of circuit breaker usable at 500 V at inside-delta circuit3RV2032-4VA10; Type of coordination 1, Iq = 15 kA, CLASS 10
of the gG fuse usable up to 690 V3NA3822-6; Type of coordination 1, Iq = 65 kA
of the gG fuse usable at inside-delta circuit up to 500 V3NA3822-6; Type of coordination 1, Iq = 65 kA
of full range R fuse link for semiconductor protection usable up to 690 V3NE1817-0; Type of coordination 2, Iq = 65 kA
of back-up R fuse link for semiconductor protection usable up to 690 V3NE8021-1; Type of coordination 2, Iq = 65 kA
General technical data
starting voltage [%]30... 100 %
stopping voltage [%]50 %; non-adjustable
start-up ramp time of soft starter0... 20 s
current limiting value [%] adjustable130... 700 %
CE markingVar
UL onayıVar
CSA approvalVar
HMI-High FeatureYok
is supported HMI-StandardVar
is supported HMI-High FeatureVar
product feature integrated bypass contact systemVar
number of controlled phases3
for main current circuit100 ms
for control circuit100 ms
insulation voltage rated value600 V
degree of pollution3, acc. to IEC 60947-4-2
impulse voltage rated value6 kV
blocking voltage of the thyristor maximum1.600 V
service factor1
surge voltage resistance rated value6 kV
between main and auxiliary circuit600 V
shock resistance15 g / 11 ms, from 12 g / 11 ms with potential contact lifting
vibration resistance15 mm to 6 Hz; 2 g to 500 Hz
utilization category according to IEC 60947-4-2AC 53a
reference code according to IEC 81346-2Q
Substance Prohibitance (day/month/year)02/15/2018
SVHC substance nameLead CAS-Yok. 7439-92-1 Lead monoxide (lead oxide) CAS-Yok. 1317-36-8 2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-Yok. 71868-10-5 Melamine CAS-Yok. 108-78-1 6,6'-di-tert-butyl-2,2'-methylenedi-p-cresol CAS-Yok. 119-47-1 Dibutylbis(pentane-2,4-dionato-O,O')tin CAS-Yok. 22673-19-4 Diboron trioxide CAS-Yok. 1303-86-2
Net Weight1,854 kg
ramp-up (soft starting)Var
soft stoppingVar
Soft TorqueVar
adjustable current limitationVar
pump stopVar
intrinsic device protectionVar
motor overload protectionVar; Full motor protection (thermistor motor protection ve electronic motor overload protection)
evaluation of thermistor motor protectionVar; Type A PTC veya Klixon / Thermoclick
inside-delta circuitVar
auto-RESETVar
manual RESETVar
remote resetVar; By turning off the control supply voltage
communication functionVar
operating measured value displayVar; Only in conjunction with special accessories
error logbookVar; Only in conjunction with special accessories
via software parameterizableYok
via software configurableVar
PROFIenergyVar; in connection with the PROFINET Standard communication module
firmware updateVar
removable terminal for control circuitVar
torque controlYok
analog outputYok
Power Electronics
at 40 °C rated value25 A
at 50 °C rated value22,3 A
at 60 °C rated value19,6 A
at 40 °C rated value43,3 A
at 50 °C rated value39 A
at 60 °C rated value33,9 A
rated value200... 480 V
at inside-delta circuit rated value200... 480 V
relative negative tolerance of the operating voltage-15 %
relative positive tolerance of the operating voltage10 %
relative negative tolerance of the operating voltage at inside-delta circuit-15 %
relative positive tolerance of the operating voltage at inside-delta circuit10 %
at 230 V at 40 °C rated value5,5 kW
at 230 V at inside-delta circuit at 40 °C rated value11 kW
at 400 V at 40 °C rated value11 kW
at 400 V at inside-delta circuit at 40 °C rated value18,5 kW
Operating frequency 1 rated value50 Hz
Operating frequency 2 rated value60 Hz
relative negative tolerance of the operating frequency-10 %
relative positive tolerance of the operating frequency10 %
at rotary coding switch on switch position 111,5 A
at rotary coding switch on switch position 212,4 A
at rotary coding switch on switch position 313,3 A
at rotary coding switch on switch position 414,2 A
at rotary coding switch on switch position 515,1 A
at rotary coding switch on switch position 616 A
at rotary coding switch on switch position 716,9 A
at rotary coding switch on switch position 817,8 A
at rotary coding switch on switch position 918,7 A
at rotary coding switch on switch position 1019,6 A
at rotary coding switch on switch position 1120,5 A
at rotary coding switch on switch position 1221,4 A
at rotary coding switch on switch position 1322,3 A
at rotary coding switch on switch position 1423,2 A
at rotary coding switch on switch position 1524,1 A
at rotary coding switch on switch position 1625 A
minimum11,5 A
for inside-delta circuit at rotary coding switch on switch position 119,9 A
for inside-delta circuit at rotary coding switch on switch position 221,5 A
for inside-delta circuit at rotary coding switch on switch position 323 A
for inside-delta circuit at rotary coding switch on switch position 424,6 A
for inside-delta circuit at rotary coding switch on switch position 526,2 A
for inside-delta circuit at rotary coding switch on switch position 627,7 A
for inside-delta circuit at rotary coding switch on switch position 729,3 A
for inside-delta circuit at rotary coding switch on switch position 830,8 A
for inside-delta circuit at rotary coding switch on switch position 932,4 A
for inside-delta circuit at rotary coding switch on switch position 1033,9 A
for inside-delta circuit at rotary coding switch on switch position 1135,5 A
for inside-delta circuit at rotary coding switch on switch position 1237,1 A
for inside-delta circuit at rotary coding switch on switch position 1338,6 A
for inside-delta circuit at rotary coding switch on switch position 1440,2 A
for inside-delta circuit at rotary coding switch on switch position 1541,7 A
for inside-delta circuit at rotary coding switch on switch position 1643,3 A
at inside-delta circuit minimum19,9 A
minimum load [%]15 %; Relative to smallest settable Ie
at 40 °C after startup20 W
at 50 °C after startup19 W
at 60 °C after startup18 W
at 40 °C during startup376 W
at 50 °C during startup318 W
at 60 °C during startup278 W
Control circuit/ Control
type of voltage of the control supply voltageAC
at 50 Hz110... 250 V
at 60 Hz110... 250 V
relative negative tolerance of the control supply voltage at AC at 50 Hz-15 %
relative positive tolerance of the control supply voltage at AC at 50 Hz10 %
relative negative tolerance of the control supply voltage at AC at 60 Hz-15 %
relative positive tolerance of the control supply voltage at AC at 60 Hz10 %
control supply voltage frequency50... 60 Hz
relative negative tolerance of the control supply voltage frequency-10 %
relative positive tolerance of the control supply voltage frequency10 %
control supply current in standby mode rated value30 mA
holding current in bypass operation rated value75 mA
inrush current by closing the bypass contacts maximum0,17 A
inrush current peak at application of control supply voltage maximum12,2 A
duration of inrush current peak at application of control supply voltage2,2 ms
design of the overvoltage protectionVaristor
design of short-circuit protection for control circuit4 A gG fuse (Icu=1 kA), 6 A quick-acting fuse (Icu=1 kA), C1 miniature circuit breaker (Icu= 600 A), C6 miniature circuit breaker (Icu= 300 A); Is not part of scope of supply
Inputs/ Outputs
number of digital inputs1
number of digital outputs3
not parameterizable2
digital output version2 normally-open contacts (NO) / 1 changeover contact (CO)
number of analog outputs0
at AC-15 at 250 V rated value3 A
at DC-13 at 24 V rated value1 A
Installation/ mounting/ dimensions
mounting position+/- 10° rotation possible ve can be tilted forward veya backward on dikey mounting surface
fastening methodscrew fixing
height275 mm
width170 mm
depth152 mm
forwards10 mm
backwards0 mm
upwards100 mm
downwards75 mm
at the side5 mm
weight without packaging2,1 kg
Connections/ Terminals
for main current circuitscrew-type terminals
for control circuitspring-loaded terminals
with conductor cross-section = 0.5 mm² maximum50 m
with conductor cross-section = 1.5 mm² maximum150 m
with conductor cross-section = 2.5 mm² maximum250 m
— solid2x (1,0... 2,5 mm²), 2x (2,5... 10 mm²)
— finely stranded with core end processing2x (1,0... 2,5 mm²), 2x (2,5... 6,0 mm²)
for AWG cables for main current circuit solid2x (16... 12), 2x (14... 8)
for control circuit solid2x (0,25... 1,5 mm²)
for control circuit finely stranded with core end processing2x (0,25... 1,5 mm²)
for AWG cables for control circuit solid2x (24... 16)
for AWG cables for control circuit finely stranded with core end processing2x (24... 16)
between soft starter and motor maximum800 m
at the digital inputs at AC maximum100 m
for main contacts with screw-type terminals2... 2,5 N·m
for auxiliary and control contacts with screw-type terminals0,8... 1,2 N·m
for main contacts with screw-type terminals18... 22 lbf·in
for auxiliary and control contacts with screw-type terminals7... 10,3 lbf·in
Ambient conditions
installation altitude at height above sea level maximum5.000 m
during operation-25... +60 °C; Please observe derating temperatures of 40 °C veya above
during storage and transport-40... +80 °C
during operation according to IEC 607213K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
during storage according to IEC 607211K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4
during transport according to IEC 607212K2, 2C1, 2S1, 2M2 (maks. fall height 0,3 m)
Electromagnetic compatibility
EMC emitted interferenceacc. to IEC 60947-4-2: Class A
Communication/ Protocol
PROFINET standardVar
EtherNet/IPVar
Modbus RTUVar
Modbus TCPVar
PROFIBUSVar
UL/CSA ratings
— at 460/480 V according to ULSiemens type: 3RV2742, maks. 70 A veya 3VA51, maks. 80 A; Iq = 5 kA
— 60/480 V according to ULSiemens type: 3RV2742, max.40 A veya 3VA51, maks. 60 A; Iq max = 65 kA
— at 460/480 V at inside-delta circuit according to ULSiemens type: 3RV2742, maks. 70 A veya 3VA51, maks. 80 A; Iq = 5 kA
— 60/480 V at inside-delta circuit according to ULSiemens type: 3VA51, maks. 60 A; Iq max = 65 kA
— at 575/600 V according to ULSiemens type: 3RV2742, maks. 70 A veya 3VA51, maks. 80 A; Iq = 5 kA
— at 575/600 V at inside-delta circuit according to ULSiemens type: 3RV2742, maks. 70 A veya 3VA51, maks. 80 A; Iq = 5 kA
— usable for Standard Faults up to 575/600 V according to ULType: Class RK5 / K5, maks. 100 A; Iq = 5 kA
— usable for High Faults up to 575/600 V according to ULType: Class J / L, maks. 100 A; Iq = 100 kA
— usable for Standard Faults at inside-delta circuit up to 575/600 V according to ULType: Class RK5 / K5, maks. 100 A; Iq = 5 kA
— usable for High Faults at inside-delta circuit up to 575/600 V according to ULType: Class J / L, maks. 100 A; Iq = 100 kA
at 200/208 V at 50 °C rated value5 hp
at 220/230 V at 50 °C rated value7,5 hp
at 460/480 V at 50 °C rated value15 hp
at 200/208 V at inside-delta circuit at 50 °C rated value10 hp
at 220/230 V at inside-delta circuit at 50 °C rated value10 hp
at 460/480 V at inside-delta circuit at 50 °C rated value25 hp
contact rating of auxiliary contacts according to ULR300-B300
Electrical Safety
protection class IP on the front according to IEC 60529IP20
touch protection on the front according to IEC 60529finger-safe, for dikey contact from the front
Approvals Certificates
global warming potential [CO2 eq] / during manufacturing37,2 kg
global warming potential [CO2 eq] / during sales0,66 kg
global warming potential [CO2 eq] / during operation152 kg
global warming potential [CO2 eq] / after end of life-4.19 kg
global warming potential [CO2 eq] / total185 kg