General technical data
size of contactorS0
function module for communicationYok
auxiliary switchVar
at AC in hot operating state4,8 W
at AC in hot operating state per pole1,6 W
without load current share typical1,3 W
type of calculation of power loss current-dependentquadratic
of main circuit with degree of pollution 3 rated value690 V
of auxiliary circuit with degree of pollution 3 rated value690 V
of main circuit rated value6 kV
of auxiliary circuit rated value6 kV
maximum permissible voltage for protective separation between coil and main contacts according to EN 60947-1400 V
at DC10g / 5 ms, 7,5g / 10 ms
at DC15 g / 5 ms, 10 g / 10 ms
of contactor typical10.000.000
of the contactor with added electronically optimized auxiliary switch block typical5.000.000
of the contactor with added auxiliary switch block typical10.000.000
reference code according to IEC 81346-2Q
Substance Prohibitance (day/month/year)10/01/2009
SVHC substance nameLead CAS-Yok. 7439-92-1 Lead monoxide (lead oxide) CAS-Yok. 1317-36-8 Melamine CAS-Yok. 108-78-1
Net Weight0,676 kg
Ambient conditions
installation altitude at height above sea level maximum2.000 m
during operation-40... +70 °C
during storage-55... +80 °C
relative humidity minimum10 %
relative humidity at 55 °C according to IEC 60068-2-30 maximum95 %
Main circuit
number of poles for main current circuit4
number of NO contacts for main contacts2
number of NC contacts for main contacts2
at AC-3 rated value maximum400 V
at AC-1 at 400 V at ambient temperature 40 °C rated value40 A
— up to 690 V at ambient temperature 40 °C rated value40 A
— up to 690 V at ambient temperature 60 °C rated value35 A
at AC-2 at 400 V rated value20 A
— at 400 V rated value20 A
at AC-4 at 400 V rated value15,5 A
at maximum AC-1 rated value10 mm²
at 400 V rated value9 A
at 690 V rated value9 A
— at 24 V rated value35 A
— at 110 V rated value4,5 A
— at 220 V rated value1 A
— at 440 V rated value0,4 A
— at 24 V rated value35 A
— at 110 V rated value35 A
— at 220 V rated value5 A
— at 440 V rated value1 A
— at 24 V rated value20 A
— at 110 V rated value2,5 A
— at 220 V rated value1 A
— at 440 V rated value0,09 A
— at 24 V rated value35 A
— at 110 V rated value15 A
— at 220 V rated value3 A
— at 440 V rated value0,27 A
at AC-2 at 400 V rated value7,5 kW
— at 230 V rated value5,5 kW
— at 400 V rated value7,5 kW
at 400 V rated value4,4 kW
at 690 V rated value7,7 kW
at DC1.500 1/h
at AC-1 maximum750 1/h
at AC-2 maximum750 1/h
at AC-3 maximum750 1/h
at AC-4 maximum200 1/h
Control circuit/ Control
type of voltageDC
type of voltage of the control supply voltageDC
control supply voltage at DC rated value72 V
initial value0,7
full-scale value1,25
design of the surge suppressorwith varistor
pickup current mean value0,13 A
pickup current peak0,19 A
duration of pickup current180 ms
closing power of magnet coil at DC13,2 W
holding power of magnet coil at DC1,3 W
at DC50... 75 ms
at DC30... 50 ms
arcing time10 ms
control version of the switch operating mechanismStandard A1 - A2
Auxiliary circuit
number of NC contacts for auxiliary contacts1
instantaneous contact1
number of NO contacts for auxiliary contacts1
instantaneous contact1
operational current at AC-12 maximum10 A
at 230 V rated value10 A
at 400 V rated value3 A
at 500 V rated value2 A
at 690 V rated value1 A
at 24 V rated value10 A
at 48 V rated value6 A
at 60 V rated value6 A
at 110 V rated value3 A
at 125 V rated value2 A
at 220 V rated value1 A
at 600 V rated value0,15 A
at 24 V rated value10 A
at 48 V rated value2 A
at 60 V rated value2 A
at 110 V rated value1 A
at 125 V rated value0,9 A
at 220 V rated value0,3 A
at 600 V rated value0,1 A
UL/CSA ratings
— at 110/120 V rated value2 hp
— at 230 V rated value3 hp
contact rating of auxiliary contacts according to ULA600 / Q600
UL File Number (CCN)E31519 (NLDX, NLDX7)
Short-circuit protection
design of the miniature circuit breaker for short-circuit protection of the auxiliary circuit up to 230 VC characteristic: 10 A; 0,4 kA
— with type of coordination 1 requiredgG: 63 A (690 V, 100 kA)
— with type of coordination 2 requiredgG: 35 A (690 V, 50 kA)
for short-circuit protection of the auxiliary switch requiredgG: 10 A (690 V, 1 kA)
Installation/ mounting/ dimensions
mounting position+/-180° rotation possible on dikey mounting surface; can be tilted forward ve backward by +/- 22,5° on dikey mounting surface
fastening method side-by-side mountingVar
fastening methodscrew ve snap-on mounting onto 35 mm DIN rail according to DIN EN 50022
height102 mm
width61 mm
depth107 mm
— forwards10 mm
— upwards10 mm
— downwards10 mm
— at the side0 mm
— forwards10 mm
— upwards10 mm
— at the side6 mm
— downwards10 mm
— forwards10 mm
— upwards10 mm
— downwards10 mm
— at the side6 mm
Connections/ Terminals
for main current circuitspring-loaded terminals
for auxiliary and control circuitspring-loaded terminals
at contactor for auxiliary contactsSpring-type terminals
of magnet coilSpring-loaded terminal
— solid2x (1... 10 mm²)
— solid or stranded2x (1... 10 mm²)
— finely stranded with core end processing2x (1... 6 mm²)
— finely stranded without core end processing2x (1... 6 mm²)
for AWG cables for main contacts2x (18... 8)
— solid2x (0,5... 2,5 mm²)
— solid or stranded2x (0,5... 2,5 mm²)
— finely stranded with core end processing2x (0,5... 1,5 mm²)
— finely stranded without core end processing2x (0,5... 1,5 mm²)
for AWG cables for auxiliary contacts2x (20... 14)
AWG number as coded connectable conductor cross section for main contacts18... 8
AWG number as coded connectable conductor cross section for auxiliary contacts20... 14
Safety related data
mirror contact according to IEC 60947-4-1Var
positively driven operation according to IEC 60947-5-1Yok
Electrical Safety
protection class IP on the front according to IEC 60529IP20
touch protection on the front according to IEC 60529finger-safe, for dikey contact from the front
Communication/ Protocol
product function bus communicationYok