Siemens 3RT2027-2AP60

power contactor, AC-3e/AC-3, 32 A, 15 kW / 400 V, 3-pole, 220 V AC, 50 Hz / 240 V, 60 Hz, auxiliary contacts: 1 NO + 1 NC, spring-loaded terminal, size: S0

SiemensMFR # 3RT2027-2AP60SKU # CEY-8EF3B02EEB50
product brand nameSIRIUS
product designationPower contactor
product type designation3RT2
size of contactorS0
function module for communicationYok
auxiliary switchVar

Ürün Hakkında

power contactor, AC-3e/AC-3, 32 A, 15 kW / 400 V, 3-pole, 220 V AC, 50 Hz / 240 V, 60 Hz, auxiliary contacts: 1 NO + 1 NC, spring-loaded terminal, size: S0

Siemens 3RT2027-2AP60

  • Orijinal ve sertifikalı Siemens ürünü
  • Dünya genelinde tedarik ağıyla hızlı temin
  • Teknik ekibimizden ürün seçimi ve uyumluluk desteği
  • Muadil ve alternatif ürün önerisi
  • Talebinize özel fiyat teklifi ve teslim süresi

Teknik Özellikler

product brand nameSIRIUS
product designationPower contactor
product type designation3RT2
General technical data
size of contactorS0
function module for communicationYok
auxiliary switchVar
at AC in hot operating state6,3 W
at AC in hot operating state per pole2,3 W
without load current share typical2,7 W
type of calculation of power loss current-dependentquadratic
of main circuit with degree of pollution 3 rated value690 V
of auxiliary circuit with degree of pollution 3 rated value690 V
of main circuit rated value6 kV
of auxiliary circuit rated value6 kV
maximum permissible voltage for protective separation between coil and main contacts according to EN 60947-1400 V
at AC8,3 g / 5 ms, 5,3 g / 10 ms
at AC13,5 g / 5 ms, 8,3 g / 10 ms
of contactor typical10.000.000
of the contactor with added electronically optimized auxiliary switch block typical5.000.000
of the contactor with added auxiliary switch block typical10.000.000
reference code according to IEC 81346-2Q
Substance Prohibitance (day/month/year)10/01/2009
Net Weight0,437 kg
Ambient conditions
installation altitude at height above sea level maximum2.000 m
during operation-25... +60 °C
during storage-55... +80 °C
relative humidity minimum10 %
relative humidity at 55 °C according to IEC 60068-2-30 maximum95 %
Main circuit
number of poles for main current circuit3
number of NO contacts for main contacts3
number of NC contacts for main contacts0
at AC-3 rated value maximum690 V
at AC-3e rated value maximum690 V
at AC-1 at 400 V at ambient temperature 40 °C rated value50 A
— up to 690 V at ambient temperature 40 °C rated value50 A
— up to 690 V at ambient temperature 60 °C rated value42 A
— at 400 V rated value32 A
— at 500 V rated value32 A
— at 690 V rated value21 A
— at 400 V rated value32 A
— at 500 V rated value32 A
— at 690 V rated value21 A
at AC-4 at 400 V rated value22 A
at AC-5a up to 690 V rated value44 A
at AC-5b up to 400 V rated value26,5 A
— up to 230 V for current peak value n=20 rated value30,8 A
— up to 400 V for current peak value n=20 rated value30,8 A
— up to 500 V for current peak value n=20 rated value27 A
— up to 690 V for current peak value n=20 rated value21 A
— up to 230 V for current peak value n=30 rated value20,5 A
— up to 400 V for current peak value n=30 rated value20,5 A
— up to 500 V for current peak value n=30 rated value18 A
— up to 690 V for current peak value n=30 rated value18 A
minimum cross-section in main circuit at maximum AC-1 rated value10 mm²
at 400 V rated value12 A
at 690 V rated value12 A
— at 24 V rated value35 A
— at 60 V rated value20 A
— at 110 V rated value4,5 A
— at 220 V rated value1 A
— at 440 V rated value0,4 A
— at 600 V rated value0,25 A
— at 24 V rated value35 A
— at 60 V rated value35 A
— at 110 V rated value35 A
— at 220 V rated value5 A
— at 440 V rated value1 A
— at 600 V rated value0,8 A
— at 24 V rated value35 A
— at 60 V rated value35 A
— at 110 V rated value35 A
— at 220 V rated value35 A
— at 440 V rated value2,9 A
— at 600 V rated value1,4 A
— at 24 V rated value20 A
— at 60 V rated value5 A
— at 220 V rated value1 A
— at 440 V rated value0,09 A
— at 600 V rated value0,06 A
— at 24 V rated value35 A
— at 60 V rated value35 A
— at 110 V rated value15 A
— at 220 V rated value3 A
— at 440 V rated value0,27 A
— at 600 V rated value0,16 A
— at 24 V rated value35 A
— at 60 V rated value35 A
— at 110 V rated value35 A
— at 220 V rated value10 A
— at 440 V rated value0,6 A
— at 600 V rated value0,6 A
— at 230 V rated value7,5 kW
— at 400 V rated value15 kW
— at 500 V rated value15 kW
— at 690 V rated value18,5 kW
— at 230 V rated value7,5 kW
— at 400 V rated value15 kW
— at 500 V rated value15 kW
— at 690 V rated value18,5 kW
at 400 V rated value6 kW
at 690 V rated value10,3 kW
up to 230 V for current peak value n=20 rated value12,2 kVA
up to 400 V for current peak value n=20 rated value21,3 kVA
up to 500 V for current peak value n=20 rated value23,3 kVA
up to 690 V for current peak value n=20 rated value25 kVA
up to 230 V for current peak value n=30 rated value8,1 kVA
up to 400 V for current peak value n=30 rated value14,2 kVA
up to 500 V for current peak value n=30 rated value15,5 kVA
up to 690 V for current peak value n=30 rated value21,5 kVA
limited to 1 s switching at zero current maximum499 A; Use minimum cross-section acc. to AC-1 rated value
limited to 5 s switching at zero current maximum341 A; Use minimum cross-section acc. to AC-1 rated value
limited to 10 s switching at zero current maximum260 A; Use minimum cross-section acc. to AC-1 rated value
limited to 30 s switching at zero current maximum199 A; Use minimum cross-section acc. to AC-1 rated value
limited to 60 s switching at zero current maximum162 A; Use minimum cross-section acc. to AC-1 rated value
at AC5.000 1/h
at AC-1 maximum1.000 1/h
at AC-2 maximum750 1/h
at AC-3 maximum750 1/h
— maximum750 1/h
at AC-4 maximum250 1/h
Control circuit/ Control
type of voltage of the control supply voltageAC
at 50 Hz rated value220 V
at 60 Hz rated value240 V
at 50 Hz0,8... 1,1
at 60 Hz0,8... 1,1
at 50 Hz81 V·A
at 60 Hz79 V·A
at 50 Hz0,72
at 60 Hz0,74
at 50 Hz10,5 V·A
at 60 Hz8,5 V·A
at 50 Hz0,25
at 60 Hz0,28
at AC8... 40 ms
at AC4... 16 ms
arcing time10 ms
control version of the switch operating mechanismStandard A1 - A2
Auxiliary circuit
number of NC contacts for auxiliary contacts instantaneous contact1
number of NO contacts for auxiliary contacts instantaneous contact1
operational current at AC-12 maximum10 A
at 230 V rated value10 A
at 400 V rated value3 A
at 500 V rated value2 A
at 690 V rated value1 A
at 24 V rated value10 A
at 48 V rated value6 A
at 60 V rated value6 A
at 110 V rated value3 A
at 125 V rated value2 A
at 220 V rated value1 A
at 600 V rated value0,15 A
at 24 V rated value10 A
at 48 V rated value2 A
at 60 V rated value2 A
at 110 V rated value1 A
at 125 V rated value0,9 A
at 220 V rated value0,3 A
at 600 V rated value0,1 A
contact reliability of auxiliary contacts1 faulty switching per 100 million (17 V, 1 mA)
UL/CSA ratings
at 480 V rated value27 A
at 600 V rated value27 A
— at 110/120 V rated value2 hp
— at 230 V rated value5 hp
— at 200/208 V rated value10 hp
— at 220/230 V rated value10 hp
— at 460/480 V rated value20 hp
— at 575/600 V rated value25 hp
contact rating of auxiliary contacts according to ULA600 / P600
UL File Number (CCN)E31519 (NLDX, NLDX7)
Short-circuit protection
design of the miniature circuit breaker for short-circuit protection of the auxiliary circuit up to 230 VC characteristic: 10 A; 0,4 kA
— with type of coordination 1 requiredgG: 125 A (690 V,100 kA), aM: 50 A (690 V,100 kA), BS88: 125 A (415 V,80 kA)
— with type of coordination 2 requiredgG: 50 A (690 V, 100 kA), aM: 25 A (690 V, 100 kA), BS88: 50 A (415 V, 80 kA)
for short-circuit protection of the auxiliary switch requiredgG: 10 A (500 V, 1 kA)
Installation/ mounting/ dimensions
mounting position+/-180° rotation possible on dikey mounting surface; can be tilted forward ve backward by +/- 22,5° on dikey mounting surface
fastening method side-by-side mountingVar
fastening methodscrew ve snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
height102 mm
width45 mm
depth97 mm
— forwards10 mm
— upwards10 mm
— downwards10 mm
— at the side0 mm
— forwards10 mm
— upwards10 mm
— at the side6 mm
— downwards10 mm
— forwards10 mm
— upwards10 mm
— downwards10 mm
— at the side6 mm
Connections/ Terminals
for main current circuitspring-loaded terminals
for auxiliary and control circuitspring-loaded terminals
at contactor for auxiliary contactsSpring-type terminals
of magnet coilSpring-loaded terminal
— solid2x (1... 10 mm²)
— solid or stranded2x (1... 10 mm²)
— finely stranded with core end processing2x (1... 6 mm²)
— finely stranded without core end processing2x (1... 6 mm²)
for AWG cables for main contacts2x (18... 8)
solid1... 10 mm²
stranded1... 10 mm²
finely stranded with core end processing1... 6 mm²
finely stranded without core end processing1... 6 mm²
solid or stranded0,5... 2,5 mm²
finely stranded with core end processing0,5... 1,5 mm²
finely stranded without core end processing0,5... 2,5 mm²
— solid or stranded2x (0,5... 2,5 mm²)
— finely stranded with core end processing2x (0,5... 1,5 mm²)
— finely stranded without core end processing2x (0,5... 2,5 mm²)
for AWG cables for auxiliary contacts2x (20... 14)
AWG number as coded connectable conductor cross section for main contacts18... 8
AWG number as coded connectable conductor cross section for auxiliary contacts20... 14
Safety related data
mirror contact according to IEC 60947-4-1Var
positively driven operation according to IEC 60947-5-1Yok
suitable for safety functionVar
suitability for use safety-related switching OFFVar
service life maximum20 a
test wear-related service life necessaryVar
with low demand rate according to SN 3192040 %
with high demand rate according to SN 3192073 %
B10 value with high demand rate according to SN 319201.000.000
failure rate [FIT] with low demand rate according to SN 31920100 FIT
ISO 13849
device type according to ISO 13849-13
overdimensioning according to ISO 13849-2 necessaryVar
IEC 61508
safety device type according to IEC 61508-2Type A
Electrical Safety
protection class IP on the front according to IEC 60529IP20
touch protection on the front according to IEC 60529finger-safe, for dikey contact from the front
Approvals Certificates
global warming potential [CO2 eq] / during manufacturing1,9 kg
global warming potential [CO2 eq] / during operation72,4 kg
global warming potential [CO2 eq] / after end of life-0.117 kg
global warming potential [CO2 eq] / total74,2 kg

İlgili Ürünler

1FG1402-..F52-4...
Siemens 1FG1402-..F52-4...
Detayları Gör

Siemens

1FG1402-..F52-4...

MFR #1FG1402-..F52-4...

SKU #YLSGOSVJU2UC8

1FG1402-..F53-4...
Siemens 1FG1402-..F53-4...
Detayları Gör

Siemens

1FG1402-..F53-4...

MFR #1FG1402-..F53-4...

SKU #YLSLVMNC14OKLTN

1FG1402-..F62-4...
Siemens 1FG1402-..F62-4...
Detayları Gör

Siemens

1FG1402-..F62-4...

MFR #1FG1402-..F62-4...

SKU #YLSMM1A2DZZYQ8G

1FG1402-..F63-4...
Siemens 1FG1402-..F63-4...
Detayları Gör

Siemens

1FG1402-..F63-4...

MFR #1FG1402-..F63-4...

SKU #YLSJMV5JSHQ7AZS

1FG1403-..C23-1...
Siemens 1FG1403-..C23-1...
Detayları Gör

Siemens

1FG1403-..C23-1...

MFR #1FG1403-..C23-1...

SKU #YLSUOUHARAHI0HN

1FG1403-..C26-2...
Siemens 1FG1403-..C26-2...
Detayları Gör

Siemens

1FG1403-..C26-2...

MFR #1FG1403-..C26-2...

SKU #YLSZHYCPSLNXAQQ

1FG1403-..C33-3...
Siemens 1FG1403-..C33-3...
Detayları Gör

Siemens

1FG1403-..C33-3...

MFR #1FG1403-..C33-3...

SKU #YLSE6XD0OTNPBV

1FG1403-..C36-4...
Siemens 1FG1403-..C36-4...
Detayları Gör

Siemens

1FG1403-..C36-4...

MFR #1FG1403-..C36-4...

SKU #YLS2DBDQW6JFQT

1FG1403-..C43-1...
Siemens 1FG1403-..C43-1...
Detayları Gör

Siemens

1FG1403-..C43-1...

MFR #1FG1403-..C43-1...

SKU #YLSGDXTBDS4UPLM

1FG1403-..C46-2...
Siemens 1FG1403-..C46-2...
Detayları Gör

Siemens

1FG1403-..C46-2...

MFR #1FG1403-..C46-2...

SKU #YLSD8X9O7E7QDLQ

Öne Çıkan Ürünler

EH22512
Danfoss Aeroquip LLC EH22512
Detayları Gör

Danfoss Aeroquip LLC

EH22512

MFR #EH22512

SKU #YLSRZ91UGVO64DG

VM8001-5
Baldor VM8001-5
Detayları Gör

Baldor

VM8001-5

MFR #VM8001-5

SKU #YLS3TOWVXWW0DHP

NCDGFN25-0100
SMC NCDGFN25-0100
Detayları Gör

SMC

NCDGFN25-0100

MFR #NCDGFN25-0100

SKU #YLST0TDV975HLIN

NCDJ2L10-300-B
SMC NCDJ2L10-300-B
Detayları Gör

SMC

NCDJ2L10-300-B

MFR #NCDJ2L10-300-B

SKU #YLSRRDWPL50RWQ2

MDBB63-100Z
SMC MDBB63-100Z
Detayları Gör

SMC

MDBB63-100Z

MFR #MDBB63-100Z

SKU #YLSNBPQBGLI90UX

BM3615T W/ 2-1/4" LONG SHAFT
Baldor BM3615T W/  2-1/4" LONG SHAFT
Detayları Gör

Baldor

BM3615T W/ 2-1/4" LONG SHAFT

MFR #BM3615T W/ 2-1/4" LONG SHAFT

SKU #YLSUV0OKQIKNTRJ

VQZ2121-5LO1-N3T
SMC VQZ2121-5LO1-N3T
Detayları Gör

SMC

VQZ2121-5LO1-N3T

MFR #VQZ2121-5LO1-N3T

SKU #YLSEL35MGGQ9FOL

MXQ25-40B-M9NZ
SMC MXQ25-40B-M9NZ
Detayları Gör

SMC

MXQ25-40B-M9NZ

MFR #MXQ25-40B-M9NZ

SKU #YLST5TX9LNATRNS

VQC2101R-51
SMC VQC2101R-51
Detayları Gör

SMC

VQC2101R-51

MFR #VQC2101R-51

SKU #YLSSEY6NT0YLZ8G

SY5420-5DZ-01
SMC SY5420-5DZ-01
Detayları Gör

SMC

SY5420-5DZ-01

MFR #SY5420-5DZ-01

SKU #YLSQW9MERWL033X

İlgili Aramalar

Siemens 3RT2027-2AP60 fiyatSiemens 3RT2027-2AP60 teklif alSiemens 3RT2027-2AP60 satın al3RT2027-2AP60 fiyat3RT2027-2AP60 stok durumuSiemens yedek parçaSiemens 3RT2027-2AP60 muadilSiemens 3RT2027-2AP60 teknik özellikler