Siemens 3RT2025-2XJ40-0LA2

Fotoğraf, ürünün gerçek halini yansıtmayabilir. Tüm detaylar için ürünün adına ve özelliklerine bakınız.

Siemens 3RT2025-2XJ40-0LA2

traction kontaktör, AC-3e/AC-3, 17 A, 7,5 kW / 400 V, 3-pole, 72 V DC, 0.7-1.25* Uc, solid-state çalışma mechanism, ile dahili varistor, yardımcı contacts: 1 NO + 1 NC, yaylı klemens, gövde boyu: S0

SiemensMFR # 3RT2025-2XJ40-0LA2SKU # CEY-8EF3B039319D
product brand nameSIRIUS
product designationPower contactor
design of the productWith extended operating range
product type designation3RT2
size of contactorS0
function module for communicationYok

Ürün Hakkında

traction kontaktör, AC-3e/AC-3, 17 A, 7,5 kW / 400 V, 3-pole, 72 V DC, 0.7-1.25* Uc, solid-state çalışma mechanism, ile dahili varistor, yardımcı contacts: 1 NO + 1 NC, yaylı klemens, gövde boyu: S0

Siemens 3RT2025-2XJ40-0LA2

  • Orijinal ve sertifikalı Siemens ürünü
  • Dünya genelinde tedarik ağıyla hızlı temin
  • Teknik ekibimizden ürün seçimi ve uyumluluk desteği
  • Muadil ve alternatif ürün önerisi
  • Talebinize özel fiyat teklifi ve teslim süresi

Teknik Özellikler

product brand nameSIRIUS
product designationPower contactor
design of the productWith extended operating range
product type designation3RT2
General technical data
size of contactorS0
function module for communicationYok
auxiliary switchVar
at AC in hot operating state2,7 W
at AC in hot operating state per pole0,9 W
without load current share typical1,3 W
type of calculation of power loss current-dependentquadratic
of main circuit with degree of pollution 3 rated value690 V
of auxiliary circuit with degree of pollution 3 rated value690 V
of main circuit rated value6 kV
of auxiliary circuit rated value6 kV
maximum permissible voltage for protective separation between coil and main contacts according to EN 60947-1400 V
at DC10g / 5 ms, 7,5g / 10 ms
at DC15 g / 5 ms, 10 g / 10 ms
of contactor typical10.000.000
of the contactor with added electronically optimized auxiliary switch block typical5.000.000
of the contactor with added auxiliary switch block typical10.000.000
reference code according to IEC 81346-2Q
Substance Prohibitance (day/month/year)10/01/2009
SVHC substance nameLead CAS-Yok. 7439-92-1 Lead monoxide (lead oxide) CAS-Yok. 1317-36-8 2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-Yok. 71868-10-5 Melamine CAS-Yok. 108-78-1
Net Weight0,556 kg
Ambient conditions
installation altitude at height above sea level maximum2.000 m
during operation-40... +70 °C
during storage-55... +80 °C
relative humidity minimum10 %
relative humidity at 55 °C according to IEC 60068-2-30 maximum95 %
Main circuit
number of poles for main current circuit3
number of NO contacts for main contacts3
at AC-3 rated value maximum690 V
at AC-3e rated value maximum690 V
at AC-1 at 400 V at ambient temperature 40 °C rated value40 A
— up to 690 V at ambient temperature 40 °C rated value40 A
— up to 690 V at ambient temperature 60 °C rated value35 A
at AC-2 at 400 V rated value17 A
— at 400 V rated value17 A
— at 500 V rated value17 A
— at 690 V rated value13 A
— at 400 V rated value17 A
— at 500 V rated value17 A
— at 690 V rated value13 A
at AC-4 at 400 V rated value15,5 A
at maximum AC-1 rated value10 mm²
at maximum Ith rated value10 mm²
at 400 V rated value7,7 A
at 690 V rated value7,7 A
— at 24 V rated value35 A
— at 110 V rated value4,5 A
— at 220 V rated value1 A
— at 440 V rated value0,4 A
— at 600 V rated value0,25 A
— at 24 V rated value35 A
— at 110 V rated value35 A
— at 220 V rated value5 A
— at 440 V rated value1 A
— at 600 V rated value0,8 A
— at 24 V rated value35 A
— at 110 V rated value35 A
— at 220 V rated value35 A
— at 440 V rated value2,9 A
— at 600 V rated value1,4 A
— at 24 V rated value20 A
— at 110 V rated value2,5 A
— at 220 V rated value1 A
— at 440 V rated value0,09 A
— at 600 V rated value0,06 A
— at 24 V rated value35 A
— at 110 V rated value15 A
— at 220 V rated value3 A
— at 440 V rated value0,27 A
— at 600 V rated value0,16 A
— at 24 V rated value35 A
— at 110 V rated value35 A
— at 220 V rated value10 A
— at 440 V rated value0,6 A
— at 600 V rated value0,6 A
at AC-2 at 400 V rated value7,5 kW
— at 230 V rated value4 kW
— at 400 V rated value7,5 kW
— at 500 V rated value7,5 kW
— at 690 V rated value11 kW
— at 230 V rated value4 kW
— at 400 V rated value7,5 kW
— at 500 V rated value7,5 kW
— at 690 V rated value11 kW
at 400 V rated value3,5 kW
at 690 V rated value6 kW
limited to 1 s switching at zero current maximum225 A; Use minimum cross-section acc. to AC-1 rated value
limited to 5 s switching at zero current maximum225 A; Use minimum cross-section acc. to AC-1 rated value
limited to 10 s switching at zero current maximum189 A; Use minimum cross-section acc. to AC-1 rated value
limited to 30 s switching at zero current maximum140 A; Use minimum cross-section acc. to AC-1 rated value
limited to 60 s switching at zero current maximum115 A; Use minimum cross-section acc. to AC-1 rated value
at DC1.500 1/h
at AC-1 maximum1.000 1/h
at AC-2 maximum1.000 1/h
at AC-3 maximum1.000 1/h
— maximum1.000 1/h
at AC-2 at AC-3e maximum1.000 1/h
at AC-4 maximum300 1/h
Ratings for railway applications
up to 40 °C according to IEC 60077 rated value40 A
up to 70 °C according to IEC 60077 rated value30 A
Control circuit/ Control
type of voltageDC
type of voltage of the control supply voltageDC
control supply voltage at DC rated value72 V
initial value0,7
full-scale value1,25
design of the surge suppressorwith varistor
duration of pickup current180 ms
closing power of magnet coil at DC13,2 W
holding power of magnet coil at DC1,3 W
at DC50... 75 ms
at DC30... 50 ms
arcing time10 ms
control version of the switch operating mechanismStandard A1 - A2
Auxiliary circuit
number of NC contacts for auxiliary contacts1
instantaneous contact1
number of NO contacts for auxiliary contacts1
instantaneous contact1
operational current at AC-12 maximum10 A
at 230 V rated value10 A
at 400 V rated value3 A
at 500 V rated value2 A
at 690 V rated value1 A
at 24 V rated value10 A
at 48 V rated value6 A
at 60 V rated value6 A
at 110 V rated value3 A
at 125 V rated value2 A
at 220 V rated value1 A
at 600 V rated value0,15 A
at 24 V rated value10 A
at 48 V rated value2 A
at 60 V rated value2 A
at 110 V rated value1 A
at 125 V rated value0,9 A
at 220 V rated value0,3 A
at 600 V rated value0,1 A
UL/CSA ratings
at 480 V rated value14 A
at 600 V rated value17 A
— at 110/120 V rated value1 hp
— at 230 V rated value3 hp
— at 200/208 V rated value3 hp
— at 220/230 V rated value5 hp
— at 460/480 V rated value10 hp
— at 575/600 V rated value15 hp
contact rating of auxiliary contacts according to ULA600 / Q600
UL File Number (CCN)E31519 (NLDX, NLDX7)
Short-circuit protection
design of the miniature circuit breaker for short-circuit protection of the auxiliary circuit up to 230 VC characteristic: 10 A; 0,4 kA
— with type of coordination 1 requiredgG: 63 A (690 V, 100 kA), aM: 32 A (690 V, 100 kA), BS88: 63 A (415 V, 80 kA)
— with type of coordination 2 requiredgG: 25 A (690 V, 100 kA), aM: 20 A (690 V, 100 kA), BS88: 25 A (415 V, 80 kA)
for short-circuit protection of the auxiliary switch requiredgG: 10 A (690 V, 1 kA)
Installation/ mounting/ dimensions
mounting position+/-180° rotation possible on dikey mounting surface; can be tilted forward ve backward by +/- 22,5° on dikey mounting surface
fastening method side-by-side mountingVar
fastening methodscrew ve snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
height102 mm
width45 mm
depth107 mm
— forwards10 mm
— upwards10 mm
— downwards10 mm
— at the side0 mm
— forwards10 mm
— upwards10 mm
— at the side6 mm
— downwards10 mm
— forwards10 mm
— upwards10 mm
— downwards10 mm
— at the side6 mm
Connections/ Terminals
for main current circuitspring-loaded terminals
for auxiliary and control circuitspring-loaded terminals
at contactor for auxiliary contactsSpring-type terminals
of magnet coilSpring-loaded terminal
— solid2x (1... 10 mm²)
— solid or stranded2x (1... 10 mm²)
— finely stranded with core end processing2x (1... 6 mm²)
— finely stranded without core end processing2x (1... 6 mm²)
for AWG cables for main contacts2x (18... 8)
— solid or stranded2x (0,5... 2,5 mm²)
— finely stranded with core end processing2x (0,5... 1,5 mm²)
— finely stranded without core end processing2x (0,5... 2,5 mm²)
for AWG cables for auxiliary contacts2x (20... 14)
AWG number as coded connectable conductor cross section for main contacts18... 8
AWG number as coded connectable conductor cross section for auxiliary contacts20... 14
Safety related data
mirror contact according to IEC 60947-4-1Var
positively driven operation according to IEC 60947-5-1Yok
suitable for safety functionVar
suitability for use safety-related switching OFFVar
service life maximum20 a
test wear-related service life necessaryVar
with low demand rate according to SN 3192040 %
with high demand rate according to SN 3192073 %
B10 value with high demand rate according to SN 319201.000.000
failure rate [FIT] with low demand rate according to SN 31920100 FIT
ISO 13849
device type according to ISO 13849-13
overdimensioning according to ISO 13849-2 necessaryVar
IEC 61508
safety device type according to IEC 61508-2Type A
Electrical Safety
protection class IP on the front according to IEC 60529IP20
touch protection on the front according to IEC 60529finger-safe, for dikey contact from the front
Communication/ Protocol
product function bus communicationYok

İlgili Ürünler

3MV8100-0MB00
Siemens 3MV8100-0MB00
Detayları Gör

Siemens

3MV8100-0MB00

MFR #3MV8100-0MB00

SKU #YLSTQVYRHTPPWXE

3MV8100-0MC00
Siemens 3MV8100-0MC00
Detayları Gör

Siemens

3MV8100-0MC00

MFR #3MV8100-0MC00

SKU #YLSNDRLO7GD0JC3

3MV8100-0MD00
Siemens 3MV8100-0MD00
Detayları Gör

Siemens

3MV8100-0MD00

MFR #3MV8100-0MD00

SKU #YLSLDR7SAMNEI7

3MV8100-0ME00
Siemens 3MV8100-0ME00
Detayları Gör

Siemens

3MV8100-0ME00

MFR #3MV8100-0ME00

SKU #YLSQYIXF5Z6DOGW

3MV8100-0MF00
Siemens 3MV8100-0MF00
Detayları Gör

Siemens

3MV8100-0MF00

MFR #3MV8100-0MF00

SKU #YLSE4VVERJVVVFH

3MV8100-0MG00
Siemens 3MV8100-0MG00
Detayları Gör

Siemens

3MV8100-0MG00

MFR #3MV8100-0MG00

SKU #YLSI4OKULAP3QK

3MV8100-0MH00
Siemens 3MV8100-0MH00
Detayları Gör

Siemens

3MV8100-0MH00

MFR #3MV8100-0MH00

SKU #YLSCUEFEDHRZRUJ

3MV8100-0MJ00
Siemens 3MV8100-0MJ00
Detayları Gör

Siemens

3MV8100-0MJ00

MFR #3MV8100-0MJ00

SKU #YLSMBKZVBRAS5T

3MV8100-0MK00
Siemens 3MV8100-0MK00
Detayları Gör

Siemens

3MV8100-0MK00

MFR #3MV8100-0MK00

SKU #YLS3JCVHPICJ2VL

3MV8100-0ML00
Siemens 3MV8100-0ML00
Detayları Gör

Siemens

3MV8100-0ML00

MFR #3MV8100-0ML00

SKU #YLSMFZC3SXLCXHP

Öne Çıkan Ürünler

BC8M12
Brush Research Mfg BC8M12
Detayları Gör

Brush Research Mfg

BC8M12

MFR #BC8M12

SKU #YLSA0P5BE6ZJCIW

VQC2101R-51
SMC VQC2101R-51
Detayları Gör

SMC

VQC2101R-51

MFR #VQC2101R-51

SKU #YLSSEY6NT0YLZ8G

VM8001-5
Baldor VM8001-5
Detayları Gör

Baldor

VM8001-5

MFR #VM8001-5

SKU #YLS3TOWVXWW0DHP

MGPL25TN-200BZ-XC9
SMC MGPL25TN-200BZ-XC9
Detayları Gör

SMC

MGPL25TN-200BZ-XC9

MFR #MGPL25TN-200BZ-XC9

SKU #YLSPBI637NOCN0Y

MDBB63-100Z
SMC MDBB63-100Z
Detayları Gör

SMC

MDBB63-100Z

MFR #MDBB63-100Z

SKU #YLSNBPQBGLI90UX

MY1M20-200AH
SMC MY1M20-200AH
Detayları Gör

SMC

MY1M20-200AH

MFR #MY1M20-200AH

SKU #YLSIZ8K8N4KBPBQ

CM2B40-75Z
SMC CM2B40-75Z
Detayları Gör

SMC

CM2B40-75Z

MFR #CM2B40-75Z

SKU #YLSOGLJ512KWTEJ

NCDMC150-0600-X155US
SMC NCDMC150-0600-X155US
Detayları Gör

SMC

NCDMC150-0600-X155US

MFR #NCDMC150-0600-X155US

SKU #YLS8ICKGSKYC93L

İlgili Aramalar

Siemens 3RT2025-2XJ40-0LA2 fiyatSiemens 3RT2025-2XJ40-0LA2 teklif alSiemens 3RT2025-2XJ40-0LA2 satın al3RT2025-2XJ40-0LA2 fiyat3RT2025-2XJ40-0LA2 stok durumuSiemens yedek parçaSiemens 3RT2025-2XJ40-0LA2 muadilSiemens 3RT2025-2XJ40-0LA2 teknik özellikler