power contactor AC-1 275 A / 690 V / 40 °C 3-pole, drive: without auxiliary contacts 2 NO + 2 NC main circuit: busbar control and auxiliary circuit: screw terminal

SiemensMFR # 3RT1456-6LA06SKU # CEY-8EF3B0393951
product brand nameSIRIUS
product designationContactor
product type designation3RT14
size of contactorS6
function module for communicationYok
auxiliary switchVar

Ürün Hakkında

power contactor AC-1 275 A / 690 V / 40 °C 3-pole, drive: without auxiliary contacts 2 NO + 2 NC main circuit: busbar control and auxiliary circuit: screw terminal

Siemens 3RT1456-6LA06

  • Orijinal ve sertifikalı Siemens ürünü
  • Dünya genelinde tedarik ağıyla hızlı temin
  • Teknik ekibimizden ürün seçimi ve uyumluluk desteği
  • Muadil ve alternatif ürün önerisi
  • Talebinize özel fiyat teklifi ve teslim süresi

Teknik Özellikler

product brand nameSIRIUS
product designationContactor
product type designation3RT14
General technical data
size of contactorS6
function module for communicationYok
auxiliary switchVar
at AC in hot operating state86,4 W
at AC in hot operating state per pole28,8 W
type of calculation of power loss current-dependentquadratic
of main circuit with degree of pollution 3 rated value1.000 V
of auxiliary circuit with degree of pollution 3 rated value500 V
of main circuit rated value8 kV
of auxiliary circuit rated value6 kV
at AC8,5 g / 5 ms, 4,2 g / 10 ms
at DC8,5 g / 5 ms, 4,2 g / 10 ms
at AC13,4 g / 5 ms, 6,5 g / 10 ms
at DC13,4 g / 5 ms, 6,5 g / 10 ms
of contactor typical10.000.000
of the contactor with added electronically optimized auxiliary switch block typical5.000.000
of the contactor with added auxiliary switch block typical10.000.000
reference code according to IEC 81346-2Q
Substance Prohibitance (day/month/year)05/01/2012
SVHC substance nameLead CAS-Yok. 7439-92-1
Net Weight2,728 kg
Ambient conditions
installation altitude at height above sea level maximum2.000 m
during operation-25... +60 °C
during storage-55... +80 °C
relative humidity minimum10 %
relative humidity at 55 °C according to IEC 60068-2-30 maximum95 %
Main circuit
number of poles for main current circuit3
number of NO contacts for main contacts3
number of NC contacts for main contacts0
type of voltage for main current circuitAC
— up to 690 V at ambient temperature 40 °C rated value275 A
— up to 690 V at ambient temperature 55 °C rated value250 A
— up to 690 V at ambient temperature 60 °C rated value250 A
— at 400 V rated value97 A
— at 690 V rated value97 A
minimum cross-section in main circuit at maximum AC-1 rated value140 mm²
— at 24 V rated value250 A
— at 60 V rated value250 A
— at 110 V rated value18 A
— at 220 V rated value3,4 A
— at 440 V rated value0,8 A
— at 600 V rated value0,5 A
— at 24 V rated value250 A
— at 60 V rated value250 A
— at 110 V rated value250 A
— at 220 V rated value20 A
— at 440 V rated value3,2 A
— at 600 V rated value1,6 A
— at 24 V rated value250 A
— at 60 V rated value250 A
— at 110 V rated value250 A
— at 220 V rated value250 A
— at 440 V rated value11,5 A
— at 600 V rated value4 A
— at 24 V rated value250 A
— at 60 V rated value7,5 A
— at 110 V rated value2,5 A
— at 220 V rated value0,6 A
— at 440 V rated value0,17 A
— at 600 V rated value0,12 A
— at 24 V rated value250 A
— at 60 V rated value250 A
— at 110 V rated value250 A
— at 220 V rated value2,5 A
— at 440 V rated value0,65 A
— at 600 V rated value0,37 A
— at 24 V rated value250 A
— at 60 V rated value250 A
— at 110 V rated value250 A
— at 220 V rated value250 A
— at 440 V rated value1,4 A
— at 600 V rated value0,75 A
at AC2.000 1/h
at DC2.000 1/h
at AC-1 maximum600 1/h
Control circuit/ Control
at AC20... 95 ms
at DC20... 95 ms
at AC40... 60 ms
at DC40... 60 ms
arcing time10... 15 ms
control version of the switch operating mechanismWithout operating mechanism
Auxiliary circuit
number of NC contacts for auxiliary contacts2
attachable4
instantaneous contact2
number of NO contacts for auxiliary contacts2
attachable4
instantaneous contact2
operational current at AC-12 maximum10 A
at 230 V rated value6 A
at 400 V rated value3 A
at 500 V rated value2 A
at 690 V rated value1 A
at 24 V rated value10 A
at 48 V rated value2 A
at 60 V rated value2 A
at 110 V rated value1 A
at 125 V rated value0,9 A
at 220 V rated value0,3 A
at 600 V rated value0,1 A
contact reliability of auxiliary contacts1 faulty switching per 100 million (17 V, 1 mA)
Short-circuit protection
design of the miniature circuit breaker for short-circuit protection of the auxiliary circuit up to 230 VC characteristic: 10 A; 0,4 kA
— with type of coordination 1 requiredgG: 355 A (690 V, 100 kA)
— with type of coordination 2 requiredgR: 350 A (690 V, 100 kA)
for short-circuit protection of the auxiliary switch requiredgG: 10 A (500 V, 1 kA)
Installation/ mounting/ dimensions
mounting positionwith dikey mounting surface +/-90° rotatable, with dikey mounting surface +/- 22,5° tiltable to the front ve back
fastening method side-by-side mountingVar
fastening methodscrew fixing
height172 mm
width120 mm
depth170 mm
— forwards20 mm
— upwards10 mm
— downwards10 mm
— at the side0 mm
— forwards20 mm
— upwards10 mm
— at the side10 mm
— downwards10 mm
— forwards20 mm
— upwards10 mm
— downwards10 mm
— at the side10 mm
Connections/ Terminals
for main current circuitConnection bar
for auxiliary and control circuitscrew-type terminals
at contactor for auxiliary contactsScrew-type terminals
of magnet coilscrew terminal
width of connection bar17 mm
thickness of connection bar3 mm
diameter of holes9 mm
number of holes1
for AWG cables for main contacts4... 250 kcmil
solid or stranded25... 120 mm²
stranded25... 120 mm²
solid or stranded0,5... 4 mm²
finely stranded with core end processing0,5... 2,5 mm²
— solid2x (0,5... 1,5 mm²), 2x (0,75... 2,5 mm²), maks. 2x (0,75... 4 mm²)
— solid or stranded2x (0,5... 1,5 mm²), 2x (0,75... 2,5 mm²), maks. 2x (0,75... 4 mm²)
— finely stranded with core end processing2x (0,5... 1,5 mm²), 2x (0,75... 2,5 mm²)
for AWG cables for auxiliary contacts2x (20... 16), 2x (18... 14), 1x 12
AWG number as coded connectable conductor cross section for auxiliary contacts18... 14
Safety related data
mirror contact according to IEC 60947-4-1Var
positively driven operation according to IEC 60947-5-1Yok
service life maximum20 a
Electrical Safety
protection class IP on the front according to IEC 60529IP00; IP20 with box terminal/cover
touch protection on the front according to IEC 60529finger-safe, for dikey contact from the front with box terminal/cover

İlgili Ürünler

1FG1304-..E02-2...
Siemens 1FG1304-..E02-2...
Detayları Gör

Siemens

1FG1304-..E02-2...

MFR #1FG1304-..E02-2...

SKU #YLS4AQXWGZPBGW

1FG1304-..E03-2...
Siemens 1FG1304-..E03-2...
Detayları Gör

Siemens

1FG1304-..E03-2...

MFR #1FG1304-..E03-2...

SKU #YLSCTI51LNFE51

1FG1304-..E04-2...
Siemens 1FG1304-..E04-2...
Detayları Gör

Siemens

1FG1304-..E04-2...

MFR #1FG1304-..E04-2...

SKU #YLSJALFZ9SI5PVT

1FG1304-..E13-4...
Siemens 1FG1304-..E13-4...
Detayları Gör

Siemens

1FG1304-..E13-4...

MFR #1FG1304-..E13-4...

SKU #YLSTD3LEQFZSPUI

1FG1304-..E14-4...
Siemens 1FG1304-..E14-4...
Detayları Gör

Siemens

1FG1304-..E14-4...

MFR #1FG1304-..E14-4...

SKU #YLS38EV3MXRMZE

1FG1304-..E22-2...
Siemens 1FG1304-..E22-2...
Detayları Gör

Siemens

1FG1304-..E22-2...

MFR #1FG1304-..E22-2...

SKU #YLS1VTYLYSZGEHH

1FG1304-..E23-2...
Siemens 1FG1304-..E23-2...
Detayları Gör

Siemens

1FG1304-..E23-2...

MFR #1FG1304-..E23-2...

SKU #YLSYJHZ7RJOW3P

1FG1304-..E24-2...
Siemens 1FG1304-..E24-2...
Detayları Gör

Siemens

1FG1304-..E24-2...

MFR #1FG1304-..E24-2...

SKU #YLSLDB8JS1BGM

1FG1304-..E32-2...
Siemens 1FG1304-..E32-2...
Detayları Gör

Siemens

1FG1304-..E32-2...

MFR #1FG1304-..E32-2...

SKU #YLSGG6PS2F7GD1A

1FG1304-..E33-2...
Siemens 1FG1304-..E33-2...
Detayları Gör

Siemens

1FG1304-..E33-2...

MFR #1FG1304-..E33-2...

SKU #YLSOH5S5SGQLUMY

Öne Çıkan Ürünler

VFSWDM3546T-5E
Baldor VFSWDM3546T-5E
Detayları Gör

Baldor

VFSWDM3546T-5E

MFR #VFSWDM3546T-5E

SKU #YLSRYYEFOOW6J5E

CM2B40-75Z
SMC CM2B40-75Z
Detayları Gör

SMC

CM2B40-75Z

MFR #CM2B40-75Z

SKU #YLSOGLJ512KWTEJ

NCDMC150-0600-X155US
SMC NCDMC150-0600-X155US
Detayları Gör

SMC

NCDMC150-0600-X155US

MFR #NCDMC150-0600-X155US

SKU #YLS8ICKGSKYC93L

MGPM25-100Z-XC4
SMC MGPM25-100Z-XC4
Detayları Gör

SMC

MGPM25-100Z-XC4

MFR #MGPM25-100Z-XC4

SKU #YLSH71U0VZZBO5I

NCDJ2L10-300-B
SMC NCDJ2L10-300-B
Detayları Gör

SMC

NCDJ2L10-300-B

MFR #NCDJ2L10-300-B

SKU #YLSRRDWPL50RWQ2

ZCUKQ25-50D
SMC ZCUKQ25-50D
Detayları Gör

SMC

ZCUKQ25-50D

MFR #ZCUKQ25-50D

SKU #YLSQ684QXTNN958

VQ1200-51-Q
SMC VQ1200-51-Q
Detayları Gör

SMC

VQ1200-51-Q

MFR #VQ1200-51-Q

SKU #YLSOVA6N31QD04G

MY1M20-200AH
SMC MY1M20-200AH
Detayları Gör

SMC

MY1M20-200AH

MFR #MY1M20-200AH

SKU #YLSIZ8K8N4KBPBQ

MXQ25L-40B-M9NZ
SMC MXQ25L-40B-M9NZ
Detayları Gör

SMC

MXQ25L-40B-M9NZ

MFR #MXQ25L-40B-M9NZ

SKU #YLSD1VANMRI726Z

CDJ2L16-125Z-B
SMC CDJ2L16-125Z-B
Detayları Gör

SMC

CDJ2L16-125Z-B

MFR #CDJ2L16-125Z-B

SKU #YLS5V0RW2VJJR1A

İlgili Aramalar

Siemens 3RT1456-6LA06 fiyatSiemens 3RT1456-6LA06 teklif alSiemens 3RT1456-6LA06 satın al3RT1456-6LA06 fiyat3RT1456-6LA06 stok durumuSiemens yedek parçaSiemens 3RT1456-6LA06 muadilSiemens 3RT1456-6LA06 teknik özellikler