thermistor motor protection relay standard evaluation unit 22.5 mm enclosure spring-loaded terminal 2 changeover contacts Us = 24 V-240 V AC/DC manual/auto/remote RESET with ATEX approval 2 LEDs (ready/tripped) electrical isolation test/RESET button wire-break monitoring short-circuit monitoring non-volatile

SiemensMFR # 3RN2012-2BW30SKU # CEY-8EF3B02C9B4F
product brand nameSIRIUS
product categorySIRIUS 3RN2 thermistor motor protection
product designationThermistor motor protection relay
product type designation3RN2
product functionthermistor motor protection
display version LEDVar

Ürün Hakkında

thermistor motor protection relay standard evaluation unit 22.5 mm enclosure spring-loaded terminal 2 changeover contacts Us = 24 V-240 V AC/DC manual/auto/remote RESET with ATEX approval 2 LEDs (ready/tripped) electrical isolation test/RESET button wire-break monitoring short-circuit monitoring non-volatile

Siemens 3RN2012-2BW30

  • Orijinal ve sertifikalı Siemens ürünü
  • Dünya genelinde tedarik ağıyla hızlı temin
  • Teknik ekibimizden ürün seçimi ve uyumluluk desteği
  • Muadil ve alternatif ürün önerisi
  • Talebinize özel fiyat teklifi ve teslim süresi

Teknik Özellikler

product brand nameSIRIUS
product categorySIRIUS 3RN2 thermistor motor protection
product designationThermistor motor protection relay
design of the productStandard evaluation unit with ATEX approval, open-circuit ve short-circuit detection in the sensor circuit, non-volatile
product type designation3RN2
General technical data
product functionthermistor motor protection
display version LEDVar
at AC in hot operating state1,7 W
at DC in hot operating state1,7 W
insulation voltage for overvoltage category III according to IEC 60664 with degree of pollution 3 rated value300 V
degree of pollution3
surge voltage resistance rated value4 kV
shock resistance according to IEC 60068-2-2711 g / 15 ms
vibration resistance according to IEC 60068-2-610... 55 Hz: 0,35 mm
mechanical service life (operating cycles) typical10.000.000
at 24 V typical100.000
at 230 V typical100.000
thermal current of the switching element with contacts maximum5 A
reference code according to IEC 81346-2K
Substance Prohibitance (day/month/year)05/28/2009
SVHC substance nameLead CAS-Yok. 7439-92-1 Lead monoxide (lead oxide) CAS-Yok. 1317-36-8 2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-Yok. 71868-10-5 Melamine CAS-Yok. 108-78-1 6,6'-di-tert-butyl-2,2'-methylenedi-p-cresol CAS-Yok. 119-47-1
Net Weight0,145 kg
Product Function
error memoryVar
dynamic open-circuit detectionVar
external resetVar
auto-RESETVar
manual RESETVar
Control circuit/ Control
type of voltage of the control supply voltageAC/DC
at 50 Hz rated value24... 240 V
at 60 Hz rated value24... 240 V
control supply voltage at DC rated value24... 240 V
initial value0,85
full-scale value1,1
initial value0,85
full-scale value1,1
initial value0,85
full-scale value1,1
at 24 V0,7 A
at 240 V12 A
at 24 V0,25 ms
at 240 V0,2 ms
Measuring circuit
buffering time in the event of power failure minimum40 ms
Precision
relative metering precision2 %
Auxiliary circuit
material of switching contactsAgSnO2
number of NC contacts for auxiliary contacts0
number of NO contacts for auxiliary contacts0
number of CO contacts for auxiliary contacts2
operational current of auxiliary contacts at AC-15 maximum3 A
at 24 V1 A
at 125 V0,2 A
at 250 V0,1 A
Main circuit
operating frequency rated value50... 60 Hz
ampacity of the output relay at AC-15 at 250 V at 50/60 Hz3 A
at 24 V1 A
at 125 V0,2 A
continuous current of the DIAZED fuse link of the output relay6 A
Electromagnetic compatibility
due to burst according to IEC 61000-4-42 kV (power ports) / 1 kV (signal ports)
due to conductor-earth surge according to IEC 61000-4-52 kV (line to ground)
due to conductor-conductor surge according to IEC 61000-4-51 kV (line to line)
electrostatic discharge according to IEC 61000-4-26 kV contact discharge / 8 kV air discharge
Galvanic isolation
design of the electrical isolationgalvanic isolation
between input and outputVar
between the outputsVar
between the voltage supply and other circuitsVar
Safety related data
failure rate [FIT] at rate of recognizable hazardous failures (λdd)6.8E-8 1/h
failure rate [FIT] at rate of non-recognizable hazardous failures (λdu)3.08E-7 1/h
average diagnostic coverage level (DCavg)18 %
MTBF97 a
MTTFd303 a
IEC 62061
Safety Integrity Level (SIL) according to IEC 62061SIL 1
PFHD with high demand rate according to IEC 620613.76E-7 1/h
ISO 13849
performance level (PL) according to EN ISO 13849-1c
category according to EN ISO 13849-11
performance level (PL) according to ISO 13849-1PL c
IEC 61508
Safety Integrity Level (SIL) according to IEC 615081
safety device type according to IEC 61508-2Type B
PFDavg with low demand rate according to IEC 615080,0041
Safe failure fraction (SFF)74 %
hardware fault tolerance according to IEC 615080
T1 value for proof test interval or service life according to IEC 615083 a
Connections/ Terminals
product component removable terminal for auxiliary and control circuitVar
type of electrical connectionspring-loaded terminal (push-in)
for auxiliary and control circuitspring-loaded terminals (push-in)
solid1x (0,5... 4 mm²)
finely stranded with core end processing1x (0,5... 2,5 mm²)
finely stranded without core end processing0,5... 4 mm²
for AWG cables solid1x (20... 12)
for AWG cables stranded20... 12
solid0,5... 4 mm²
finely stranded with core end processing0,5... 2,5 mm²
finely stranded without core end processing0,5... 4 mm²
solid20... 12
stranded20... 12
Installation/ mounting/ dimensions
mounting positionany
fastening methodscrew ve snap-on mounting onto 35 mm DIN rail
height100 mm
width22,5 mm
depth90 mm
— forwards0 mm
— backwards0 mm
— upwards0 mm
— downwards0 mm
— at the side0 mm
— forwards0 mm
— backwards0 mm
— upwards0 mm
— at the side0 mm
— downwards0 mm
— forwards0 mm
— backwards0 mm
— upwards0 mm
— downwards0 mm
— at the side0 mm
Ambient conditions
installation altitude at height above sea level maximum2.000 m
during operation-25... +60 °C
during storage-40... +85 °C
during transport-40... +85 °C
relative humidity during operation maximum70 %
explosion protection category for dust[Ex t] [Ex p]
explosion protection category for gas[Ex e] [Ex d] [Ex px]

Aksesuarlar 4

Siemens 3RN2012-2BW30 motorla birlikte kullanılabilen, ayrı olarak tedarik edilen orijinal aksesuarlar aşağıda listelenmiştir. Koda tıklayarak aksesuarın sayfasına ve uyumlu diğer motorlara ulaşabilirsiniz.

Parça noAçıklamaUyumlu motor
3ZY1311-0AA00Aksesuar · Further accessories
3ZY1122-1BA00Aksesuar · Removable terminals
3ZY1440-1AA00Aksesuar · Further accessories
3ZY1122-2BA00Aksesuar · Removable terminals

İlgili Ürünler

1EE1122-..A00-...4
Siemens 1EE1122-..A00-...4
Detayları Gör

Siemens

1EE1122-..A00-...4

MFR #1EE1122-..A00-...4

SKU #YLS3FGFZLYE3EV8

1EE1124-..A00-...4
Siemens 1EE1124-..A00-...4
Detayları Gör

Siemens

1EE1124-..A00-...4

MFR #1EE1124-..A00-...4

SKU #YLSKZIN1GEIPRVP

1EE1142-..A00-...4
Siemens 1EE1142-..A00-...4
Detayları Gör

Siemens

1EE1142-..A00-...4

MFR #1EE1142-..A00-...4

SKU #YLSUX3MNEZEJGPU

1EE1144-..A00-...4
Siemens 1EE1144-..A00-...4
Detayları Gör

Siemens

1EE1144-..A00-...4

MFR #1EE1144-..A00-...4

SKU #YLSD9GON9QOYBAE

1EE1322-....0-...4
Siemens 1EE1322-....0-...4
Detayları Gör

Siemens

1EE1322-....0-...4

MFR #1EE1322-....0-...4

SKU #YLSSAVZE8P7OOP6

1EE1322-...00-1..2
Siemens 1EE1322-...00-1..2
Detayları Gör

Siemens

1EE1322-...00-1..2

MFR #1EE1322-...00-1..2

SKU #YLSY69IQB2JXAXJ

1EE1322-..A00-...4
Siemens 1EE1322-..A00-...4
Detayları Gör

Siemens

1EE1322-..A00-...4

MFR #1EE1322-..A00-...4

SKU #YLSH1E6AJR6XWJF

1EE1324-....0-...4
Siemens 1EE1324-....0-...4
Detayları Gör

Siemens

1EE1324-....0-...4

MFR #1EE1324-....0-...4

SKU #YLS8GBB9BXAF83

1EE1324-...00-1..2
Siemens 1EE1324-...00-1..2
Detayları Gör

Siemens

1EE1324-...00-1..2

MFR #1EE1324-...00-1..2

SKU #YLSLOS6I1BDXR58

1EE1324-..A00-...4
Siemens 1EE1324-..A00-...4
Detayları Gör

Siemens

1EE1324-..A00-...4

MFR #1EE1324-..A00-...4

SKU #YLSE0T3LUEU0CI

Öne Çıkan Ürünler

MXQ25-40B-M9NZ
SMC MXQ25-40B-M9NZ
Detayları Gör

SMC

MXQ25-40B-M9NZ

MFR #MXQ25-40B-M9NZ

SKU #YLST5TX9LNATRNS

EH22512
Danfoss Aeroquip LLC EH22512
Detayları Gör

Danfoss Aeroquip LLC

EH22512

MFR #EH22512

SKU #YLSRZ91UGVO64DG

CM2B40-75Z
SMC CM2B40-75Z
Detayları Gör

SMC

CM2B40-75Z

MFR #CM2B40-75Z

SKU #YLSOGLJ512KWTEJ

NCDMC150-0600-X155US
SMC NCDMC150-0600-X155US
Detayları Gör

SMC

NCDMC150-0600-X155US

MFR #NCDMC150-0600-X155US

SKU #YLS8ICKGSKYC93L

MXQ25L-40B-M9NZ
SMC MXQ25L-40B-M9NZ
Detayları Gör

SMC

MXQ25L-40B-M9NZ

MFR #MXQ25L-40B-M9NZ

SKU #YLSD1VANMRI726Z

MGPL25TN-200BZ-XC9
SMC MGPL25TN-200BZ-XC9
Detayları Gör

SMC

MGPL25TN-200BZ-XC9

MFR #MGPL25TN-200BZ-XC9

SKU #YLSPBI637NOCN0Y

SY5420-5DZ-01
SMC SY5420-5DZ-01
Detayları Gör

SMC

SY5420-5DZ-01

MFR #SY5420-5DZ-01

SKU #YLSQW9MERWL033X

BM3615T W/ 2-1/4" LONG SHAFT
Baldor BM3615T W/  2-1/4" LONG SHAFT
Detayları Gör

Baldor

BM3615T W/ 2-1/4" LONG SHAFT

MFR #BM3615T W/ 2-1/4" LONG SHAFT

SKU #YLSUV0OKQIKNTRJ

AR30-N02E-1Z-B
SMC AR30-N02E-1Z-B
Detayları Gör

SMC

AR30-N02E-1Z-B

MFR #AR30-N02E-1Z-B

SKU #YLSYFNHADE6GRKV

İlgili Aramalar

Siemens 3RN2012-2BW30 fiyatSiemens 3RN2012-2BW30 teklif alSiemens 3RN2012-2BW30 satın al3RN2012-2BW30 fiyat3RN2012-2BW30 stok durumuSiemens yedek parçaSiemens 3RN2012-2BW30 muadilSiemens 3RN2012-2BW30 teknik özellikler