product brand nameSIRIUS
product designationReversing contactor assembly
product type designation3RA23
1 of the supplied contactor3RT2018-2BW42
2 of the supplied contactor3RT2018-2BW42
of the supplied RH assembly kit3RA2913-2AA2
General technical data
size of contactorS00
product extension auxiliary switchVar
at AC7,3 g / 5 ms, 4,7 g / 10 ms
at DC7,3 g / 5 ms, 4,7 g / 10 ms
at AC11,4 g / 5 ms, 7,3 g / 10 ms
at DC11,4 g / 5 ms, 7,3g / 10 ms
of contactor typical10.000.000
of the contactor with added auxiliary switch block typical10.000.000
reference code according to IEC 81346-2Q
Substance Prohibitance (day/month/year)10/01/2009
Net Weight0,655 kg
Ambient conditions
installation altitude at height above sea level maximum2.000 m
during operation-25... +60 °C
during storage-55... +80 °C
Main circuit
number of poles for main current circuit3
number of NO contacts for main contacts3
number of NC contacts for main contacts0
at AC-3 rated value maximum690 V
at AC-3e rated value maximum690 V
— at 400 V rated value16 A
— at 500 V rated value12,4 A
— at 690 V rated value8,9 A
— at 400 V rated value16 A
— at 500 V rated value12,4 A
— at 690 V rated value8,9 A
— at 400 V rated value7,5 kW
— at 500 V rated value7,5 kW
— at 690 V rated value7,5 kW
— at 400 V rated value7,5 kW
— at 690 V rated value7,5 kW
at AC-4 at 400 V rated value5,5 kW
at AC-3 maximum750 1/h
at AC-3e maximum750 1/h
Control circuit/ Control
type of voltage of the control supply voltageDC
control supply voltage 1 at DC rated value48 V
closing power of magnet coil at DC4 W
holding power of magnet coil at DC4 W
Auxiliary circuit
contact reliability of auxiliary contacts< 1 error per 100 million operating cycles
UL/CSA ratings
at 480 V rated value14 A
at 600 V rated value11 A
at 200/208 V rated value3 hp
at 220/230 V rated value5 hp
at 460/480 V rated value10 hp
at 575/600 V rated value10 hp
contact rating of auxiliary contacts according to ULA600 / Q600
Short-circuit protection
— with type of coordination 1 requiredgG NH 3NA, DIAZED 5SB, NEOZED 5SE: 50 A
— with type of coordination 2 requiredgG NH 3NA, DIAZED 5SB, NEOZED 5SE: 25 A
for short-circuit protection of the auxiliary switch requiredfuse gG: 10 A
Installation/ mounting/ dimensions
mounting position+/-180° rotation possible on dikey mounting surface; can be tilted forward ve backward by +/- 22,5° on dikey mounting surface
fastening methodscrew ve snap-on mounting onto 35 mm DIN rail
height84 mm
width90 mm
depth83 mm
— forwards6 mm
— backwards0 mm
— upwards6 mm
— downwards6 mm
— at the side6 mm
— forwards6 mm
— backwards0 mm
— upwards6 mm
— at the side6 mm
— downwards6 mm
— forwards6 mm
— backwards0 mm
— upwards6 mm
— downwards6 mm
— at the side6 mm
Connections/ Terminals
for main current circuitspring-loaded terminals
for auxiliary and control circuitspring-loaded terminals
at contactor for auxiliary contactsSpring-type terminals
of magnet coilSpring-loaded terminal
solid2x (0,5... 4 mm²)
solid or stranded2x (0,5... 4 mm²)
finely stranded with core end processing2x (0,5... 2,5 mm²)
finely stranded without core end processing2x (0,5... 2,5 mm²)
— solid or stranded2x (0,5... 2,5 mm²)
— finely stranded with core end processing2x (0,5... 1,5 mm²)
— finely stranded without core end processing2x (0,5... 1,5 mm²)
for AWG cables for auxiliary contacts2x (20... 14)
Safety related data
product function suitable for safety functionVar
Electrical Safety
protection class IP on the front according to IEC 60529IP20
touch protection on the front according to IEC 60529finger-safe, for dikey contact from the front
Communication/ Protocol
product function bus communicationVar
protocol is supported AS-Interface protocolYok
product function control circuit interface with IO linkYok