Anma ölçüsü [mm]PSK-060
Dynamic load capacity, guideway Cgw50 [N]23540,0
Dynamic load capacity guideway Cgw100 [N]18700,0
Maks. ivme amax [m/s²]50,0
Not: Maks. ivme amaxThe maximum value is dependent on the selected configuration.
İzin verilen maks. doğrusal hız vmax [m/s]1,17
Not: Maximum permissible speed vmaxThe maximum value is dependent on the selected configuration.
Dynamic load capacity, fixed bearing Cfb [N]8500
Dynamic load capacity, ball screw assembly Cbs [N]4100
Maximum permissible dynamic torsional moment about the x-axis Mx max [Nm]112
Maximum permissible dynamic torsional moment about the y-axis My max [Nm]280
Not: Maximum permissible dynamic torsional moment about the y-axis My maxThe maximum value is dependent on the selected configuration.
Maximum permissible dynamic torsional moment about the z-axis Mz max [Nm]212
Not: Maximum permissible dynamic torsional moment about the z-axis Mz maxThe maximum value is dependent on the selected configuration.
Maximum dynamic load in y-direction Fy max [N]5600
Not: Maximum dynamic load in y-direction Fy maxThe maximum value is dependent on the selected configuration.
Maximum dynamic load in z1-direction Fz1 max [N]7400
Maximum dynamic load in z2-direction Fz2 max [N]7400
Planar moment of inertia about the y-axis ly [cm⁴]2,42
Planar moment of inertia about the z-axis lz [cm⁴]28,82
Permissible ambient temperature with Rexroth servo motor (min. ... max.)0 °C ... 40 °C
Not: Permissible ambient temperature with Rexroth servo motor (min. ... max.)loss of performance at 40 °C or higher
Permissible ambient temperature mechanics (min. … max.)-10 °C ... 60 °C
Not: Permissible ambient temperature mechanics (min. … max.)Yok dropping below dew point
Ağırlık [kg]0
Not: Dynamic load capacity, fixed bearing CfbThe maximum value is dependent on the selected configuration.
Not: Dynamic load capacity, guideway Cgw100The determination of the dynamic load capacities and load moments is based on a 100,000 m travel according to DIN ISO 14728-1. The maximum value is dependent on the selected configuration.
Not: Dynamic load capacity, guideway Cgw50The determination of the dynamic load capacities and load moments is based on a 50,000 m travel according to DIN ISO 14728-1. The maximum value is dependent on the selected configuration.
Not: Dynamic load capacity, ball screw assembly CbsThe maximum value is dependent on the selected configuration.
Dinamik burulma momenti yük kapasitesi Mt50 [Nm]430,0
Not: Dinamik burulma momenti yük kapasitesi Mt50The determination of the dynamic load capacities and load moments is based on a 50,000 m travel according to DIN ISO 14728-1. The maximum value is dependent on the selected configuration.
Dinamik burulma momenti yük kapasitesi Mt100 [Nm]345,0
Not: Dinamik burulma momenti yük kapasitesi Mt100The determination of the dynamic load capacities and load moments is based on a 100,000 m travel according to DIN ISO 14728-1. The maximum value is dependent on the selected configuration.
Dinamik boyuna moment yük kapasitesi ML50 [Nm]883,0
Not: Dinamik boyuna moment yük kapasitesi ML50The determination of the dynamic load capacities and load moments is based on a 50,000 m travel according to DIN ISO 14728-1. The maximum value is dependent on the selected configuration.
Dinamik boyuna moment yük kapasitesi ML100 [Nm]701,0
Not: Dinamik boyuna moment yük kapasitesi ML100The determination of the dynamic load capacities and load moments is based on a 100,000 m travel according to DIN ISO 14728-1. The maximum value is dependent on the selected configuration.