
Siemens
1EE1122-..A00-...4
MFR #1EE1122-..A00-...4
SKU #YLS3FGFZLYE3EV8
We use cookies on our website to provide you with a better experience. Cookies are used to improve site performance, personalize content, and analyze traffic.

Photo may not represent actual item. Refer to name and product specs for all details.
RDF870MB - Flush mount touch MODBUS PM2.5 & CO2 & Ventilation Controls with on/off or ECM fans selectable and 2x DC 0-10 V input, fit for both round and square conduit boxes. AC 230 V operating voltage, large, backlit display Display and setpoint adjustment for PM2.5 and CO2 control Display of room temperature, outside temperature, VOC (volatile organic compound) and RH (relative humidity) Support 1-/3-/4-speed On/Off fan or DC fan output Two multifunctional inputs for external passive and DC 0...10 V sensors Operating modes: Comfort, Economy and Protection RS485 Modbus RTU slave mode Modbus commissioning via third-party tool, e.g. Modbus scan, Modbus poll, etc Mounting on recessed square 86 mm box or round 60 mm with 60 mm fixing centers and minimum 40 mm depth Color of housing: Ivory white (RAL 9001) RDF870MB can be configured as a room unit via DIP switches. It provides the following additional functions: Setpoint adjustment and display for room temperature, VOC, RH and display of outside temperature Four remote digital outputs via bus and controlled by a master controller Application selectable: PM2.5 control only CO2 control only PM2.5 & CO2 controls (CO2 higher priority in control) Ventilation control
RDF870MB - Flush mount touch MODBUS PM2.5 & CO2 & Ventilation Controls with on/off or ECM fans selectable and 2x DC 0-10 V input, fit for both round and square conduit boxes. AC 230 V operating voltage, large, backlit display Display and setpoint adjustment for PM2.5 and CO2 control Display of room temperature, outside temperature, VOC (volatile organic compound) and RH (relative humidity) Support 1-/3-/4-speed On/Off fan or DC fan output Two multifunctional inputs for external passive and DC 0...10 V sensors Operating modes: Comfort, Economy and Protection RS485 Modbus RTU slave mode Modbus commissioning via third-party tool, e.g. Modbus scan, Modbus poll, etc Mounting on recessed square 86 mm box or round 60 mm with 60 mm fixing centers and minimum 40 mm depth Color of housing: Ivory white (RAL 9001) RDF870MB can be configured as a room unit via DIP switches. It provides the following additional functions: Setpoint adjustment and display for room temperature, VOC, RH and display of outside temperature Four remote digital outputs via bus and controlled by a master controller Application selectable: PM2.5 control only CO2 control only PM2.5 & CO2 controls (CO2 higher priority in control) Ventilation control

Siemens
MFR #1EE1122-..A00-...4
SKU #YLS3FGFZLYE3EV8

Siemens
MFR #1EE1124-..A00-...4
SKU #YLSKZIN1GEIPRVP

Siemens
MFR #1EE1142-..A00-...4
SKU #YLSUX3MNEZEJGPU

Siemens
MFR #1EE1144-..A00-...4
SKU #YLSD9GON9QOYBAE

Siemens
MFR #1EE1322-....0-...4
SKU #YLSSAVZE8P7OOP6

Siemens
MFR #1EE1322-...00-1..2
SKU #YLSY69IQB2JXAXJ

Siemens
MFR #1EE1322-..A00-...4
SKU #YLSH1E6AJR6XWJF

Siemens
MFR #1EE1324-....0-...4
SKU #YLS8GBB9BXAF83

Siemens
MFR #1EE1324-...00-1..2
SKU #YLSLOS6I1BDXR58

Siemens
MFR #1EE1324-..A00-...4
SKU #YLSE0T3LUEU0CI

SMC
MFR #MGPL25TN-200BZ-XC9
SKU #YLSPBI637NOCN0Y

SMC
MFR #MXQ25-40B-M9NZ
SKU #YLST5TX9LNATRNS

SMC
MFR #CG5EN50SV-150
SKU #YLST11TLVYPVP7H

SMC
MFR #AL30-03-8-A
SKU #YLS6GDABZE4BN7A

SMC
MFR #VQZ2121-5LO1-N3T
SKU #YLSEL35MGGQ9FOL

SMC
MFR #VQ1200-51-Q
SKU #YLSOVA6N31QD04G

SMC
MFR #ZCUKQ25-50D
SKU #YLSQ684QXTNN958

SMC
MFR #CM2B40-75Z
SKU #YLSOGLJ512KWTEJ

SMC
MFR #AC40B-N04G-RZ-B F/R COMBO MODULAR
SKU #YLS1HII4JHHH09L

SMC
MFR #NCDJ2L10-300-B
SKU #YLSRRDWPL50RWQ2
Siemens S55770-T408 priceSiemens S55770-T408 quotebuy Siemens S55770-T408S55770-T408 priceS55770-T408 stock availabilitySiemens spare partsSiemens S55770-T408 equivalentSiemens S55770-T408 specifications