Siemens
1EE1122-..A00-...4
MFR #1EE1122-..A00-...4
SKU #YLS3FGFZLYE3EV8
We use cookies on our website to provide you with a better experience. Cookies are used to improve site performance, personalize content, and analyze traffic.

Photo may not represent actual item. Refer to name and product specs for all details.
Device: 7SJ82 overcurrent protection Product code Short: P1J126344 Long: 7SJ82-DAAA-AA0-0AAAA0-AH0211-12111B-AAA000-000AB0-HB1BD2-JZ0 Enclosure width : 1/3 x 19" Enclosure type: Installation Binary inputs 11 Binary outputs 9 standard relays Current transformer: 4 for protection, 0 for measurement and sensitive earth current acquisition Current transformer: 4 Transmitter inputs: 0 (20 mA or 10 V, fast) 0 (20mA) CPU: CP100 Modules in 19" row 1: IO102 , PS101 Modules in 19" row 2: Number of LEDs: 16 Operating unit Integrated Key-operated switch: without display type: Small display front design: standard Auxiliary voltage: 24 V / 48 V DC Communication / plug-in modules: Communication encryption Normal Integrated Ethernet port J: for DIGSI 5 Plug-in module position E: ETH-BA-2EL: 2 x electrical Ethernet, RJ45, suitable for DIGSI, IEC 61850, DNP etc. Plug-in module position F: Port is available, but not equipped UL NRGU.E194016 / cUL NRGU7.E194016 Functions: Function points class: Basis + 100 function points ANSI: functions (included in the base) protection functions for 3-pole resolution, 37 Undercurrent 38 Temperature monitoring, 46 Negative-sequence system overcurrent protection, 46 Phase balance current protection (thermal), 49 Thermal overload protection, 50N/ 51N TD Time overcurrent protection, Ground, 50HS High-speed overcurrent protection, -- Fast tripping when switching on to a fault, 50N/ 51N TD Time overcurrent protection, 1-phase, 50Ns/ 51Ns Sensitive ground current protection for deleted and isola Networks, 74TC Trip circuit supervision, 86 Lockout AFD Arc protection (only with plug-in module ARC-CD-3FO), -- Measured values, standard, -- Switching statistics, -- CFC (standard, control), -- Switching sequence function, -- Inrush-current detection, -- External trip initiation, -- Control, -- Fault recording of analog and binary signals -- Monitoring, -- Protection interface, serial
Device: 7SJ82 overcurrent protection Product code Short: P1J126344 Long: 7SJ82-DAAA-AA0-0AAAA0-AH0211-12111B-AAA000-000AB0-HB1BD2-JZ0 Enclosure width : 1/3 x 19" Enclosure type: Installation Binary inputs 11 Binary outputs 9 standard relays Current transformer: 4 for protection, 0 for measurement and sensitive earth current acquisition Current transformer: 4 Transmitter inputs: 0 (20 mA or 10 V, fast) 0 (20mA) CPU: CP100 Modules in 19" row 1: IO102 , PS101 Modules in 19" row 2: Number of LEDs: 16 Operating unit Integrated Key-operated switch: without display type: Small display front design: standard Auxiliary voltage: 24 V / 48 V DC Communication / plug-in modules: Communication encryption Normal Integrated Ethernet port J: for DIGSI 5 Plug-in module position E: ETH-BA-2EL: 2 x electrical Ethernet, RJ45, suitable for DIGSI, IEC 61850, DNP etc. Plug-in module position F: Port is available, but not equipped UL NRGU.E194016 / cUL NRGU7.E194016 Functions: Function points class: Basis + 100 function points ANSI: functions (included in the base) protection functions for 3-pole resolution, 37 Undercurrent 38 Temperature monitoring, 46 Negative-sequence system overcurrent protection, 46 Phase balance current protection (thermal), 49 Thermal overload protection, 50N/ 51N TD Time overcurrent protection, Ground, 50HS High-speed overcurrent protection, -- Fast tripping when switching on to a fault, 50N/ 51N TD Time overcurrent protection, 1-phase, 50Ns/ 51Ns Sensitive ground current protection for deleted and isola Networks, 74TC Trip circuit supervision, 86 Lockout AFD Arc protection (only with plug-in module ARC-CD-3FO), -- Measured values, standard, -- Switching statistics, -- CFC (standard, control), -- Switching sequence function, -- Inrush-current detection, -- External trip initiation, -- Control, -- Fault recording of analog and binary signals -- Monitoring, -- Protection interface, serial

Siemens
MFR #1EE1122-..A00-...4
SKU #YLS3FGFZLYE3EV8

Siemens
MFR #1EE1124-..A00-...4
SKU #YLSKZIN1GEIPRVP

Siemens
MFR #1EE1142-..A00-...4
SKU #YLSUX3MNEZEJGPU

Siemens
MFR #1EE1144-..A00-...4
SKU #YLSD9GON9QOYBAE

Siemens
MFR #1EE1322-....0-...4
SKU #YLSSAVZE8P7OOP6

Siemens
MFR #1EE1322-...00-1..2
SKU #YLSY69IQB2JXAXJ

Siemens
MFR #1EE1322-..A00-...4
SKU #YLSH1E6AJR6XWJF

Siemens
MFR #1EE1324-....0-...4
SKU #YLS8GBB9BXAF83

Siemens
MFR #1EE1324-...00-1..2
SKU #YLSLOS6I1BDXR58

Siemens
MFR #1EE1324-..A00-...4
SKU #YLSE0T3LUEU0CI

SMC
MFR #MTS32-150M
SKU #YLSSJCSBTRLX2P7

Baldor
MFR #VM8001-5
SKU #YLS3TOWVXWW0DHP

SMC
MFR #AC20A-01G-V-1-B FR/L COMBO MODULAR
SKU #YLSSMWXCWLO2KA6

SMC
MFR #NCDJ2L10-300-B
SKU #YLSRRDWPL50RWQ2

SMC
MFR #VQZ2121-5LO1-N3T
SKU #YLSEL35MGGQ9FOL

Baldor
MFR #BM3615T W/ 2-1/4" LONG SHAFT
SKU #YLSUV0OKQIKNTRJ

SMC
MFR #MDBB63-100Z
SKU #YLSNBPQBGLI90UX

SMC
MFR #MXQ25-40B-M9NZ
SKU #YLST5TX9LNATRNS

SMC
MFR #MGPL25TN-200BZ-XC9
SKU #YLSPBI637NOCN0Y

SMC
MFR #AR30-N02E-1Z-B
SKU #YLSYFNHADE6GRKV
Siemens P1J126344 priceSiemens P1J126344 quotebuy Siemens P1J126344P1J126344 priceP1J126344 stock availabilitySiemens spare partsSiemens P1J126344 equivalentSiemens P1J126344 specifications