
Siemens
410455828
MFR #410455828
SKU #YLSL5RI1TVEAXYN
We use cookies on our website to provide you with a better experience. Cookies are used to improve site performance, personalize content, and analyze traffic.

Photo may not represent actual item. Refer to name and product specs for all details.
PAD-3R - Power Supply with Red Enclosure. Designed for use with Siemens Building Technologies, Fire Safety Division fire alarm control panels, the PAD-3 is a Notification Appliance Circuit Expander with a built-in auxiliary power output. It is This power source is designed to provide the extra power required in buildings conforming to the Americans with Disabilities Act. The PAD-3 provides 6 amps of 24 VDC power for multiple uses. All 6 Amps can be directed to 4 Notification Appliance Circuits (NAC s). Each is rated at 3 A and is power limited. Either 1 or 2 inputs can control the four outputs. These outputs are compatible with all Fire Safety 24 VDC notification appliances. The PAD-3 can be configured so that the inputs can be programmed as steady outputs, ANSI temporal outputs, or synchronized strobe outputs. It can also be programmed so that one input will silence U-MHU Series horn/strobe horns while the strobes remain on using one set of wires. The PAD-3 also offers a 3 Amp auxiliary output for driving other portions of your fire alarm system such as door holders. This 24 VDC filtered output is power limited. When using this output, the total power available from the PAD-3 will not exceed 6 Amps. A trouble contact is provided for monitoring the PAD-3with a fire alarm panel through the input. It also has a Form C dry contact for trouble monitoring, allowing the user has the option of connecting it to a conventional fire alarm panel’s existing notification circuit, or controlling it with a TRI Series device on intelligent fire systems. The PAD-3 offers battery supervision and management as is required of fire alarm system components. Ground faults are transmitted as are any other trouble conditions. Trouble conditions not only change the state of the trouble contact in the unit, but they also break the notification circuit input to create a trouble signal in the fire alarm control unit. System 3 enclosures may also be used to house multiple PAD-3 modules in a single enclosure. Two modules are capable of sharing the same battery set when mounted in the same enclosure. UL, ULC Listed, CSFM, NYMEA and FM Approved. Red Enclosure.
PAD-3R - Power Supply with Red Enclosure. Designed for use with Siemens Building Technologies, Fire Safety Division fire alarm control panels, the PAD-3 is a Notification Appliance Circuit Expander with a built-in auxiliary power output. It is This power source is designed to provide the extra power required in buildings conforming to the Americans with Disabilities Act. The PAD-3 provides 6 amps of 24 VDC power for multiple uses. All 6 Amps can be directed to 4 Notification Appliance Circuits (NAC s). Each is rated at 3 A and is power limited. Either 1 or 2 inputs can control the four outputs. These outputs are compatible with all Fire Safety 24 VDC notification appliances. The PAD-3 can be configured so that the inputs can be programmed as steady outputs, ANSI temporal outputs, or synchronized strobe outputs. It can also be programmed so that one input will silence U-MHU Series horn/strobe horns while the strobes remain on using one set of wires. The PAD-3 also offers a 3 Amp auxiliary output for driving other portions of your fire alarm system such as door holders. This 24 VDC filtered output is power limited. When using this output, the total power available from the PAD-3 will not exceed 6 Amps. A trouble contact is provided for monitoring the PAD-3with a fire alarm panel through the input. It also has a Form C dry contact for trouble monitoring, allowing the user has the option of connecting it to a conventional fire alarm panel’s existing notification circuit, or controlling it with a TRI Series device on intelligent fire systems. The PAD-3 offers battery supervision and management as is required of fire alarm system components. Ground faults are transmitted as are any other trouble conditions. Trouble conditions not only change the state of the trouble contact in the unit, but they also break the notification circuit input to create a trouble signal in the fire alarm control unit. System 3 enclosures may also be used to house multiple PAD-3 modules in a single enclosure. Two modules are capable of sharing the same battery set when mounted in the same enclosure. UL, ULC Listed, CSFM, NYMEA and FM Approved. Red Enclosure.

Siemens
MFR #410455828
SKU #YLSL5RI1TVEAXYN

Siemens
MFR #500-019614
SKU #YLSLWCTJNEBHGM

Siemens
MFR #500-688977
SKU #YLSIOUQOSOIRZHE

Siemens
MFR #5WG1125-1AB13
SKU #YLSTYMOKKXUB0

Siemens
MFR #5WG1125-1AB23
SKU #YLSLERTZCFLXF0P

Siemens
MFR #5WG1125-4CB33
SKU #YLSW0XGZCPXHCDE

Siemens
MFR #5WG1141-1AB14
SKU #YLSVGXP12BHBWLH

Siemens
MFR #5WG1141-1AB32
SKU #YLSY0VBN7VTSVY

Siemens
MFR #5WG1146-1AB03
SKU #YLSAGHWH4KDB30E

Siemens
MFR #5WG1148-1AB23
SKU #YLSLJIXSIVM1Y

Brush Research Mfg
MFR #BC8M12
SKU #YLSA0P5BE6ZJCIW

SMC
MFR #AR30-N02E-1Z-B
SKU #YLSYFNHADE6GRKV

SMC
MFR #AW20-N02CG-6CZ-B
SKU #YLSNOOF0IBCZ3J3

SMC
MFR #NCDJ2L10-300-B
SKU #YLSRRDWPL50RWQ2

SMC
MFR #AL30-03-8-A
SKU #YLS6GDABZE4BN7A

SMC
MFR #CM2B40-75Z
SKU #YLSOGLJ512KWTEJ

SMC
MFR #MY1M20-200AH
SKU #YLSIZ8K8N4KBPBQ

SMC
MFR #NCDGFN25-0100
SKU #YLST0TDV975HLIN

SMC
MFR #MXS-AS16L
SKU #YLSAP0XXFGFSWY6

SMC
MFR #SY5420-5DZ-01
SKU #YLSQW9MERWL033X
Siemens BPZ:599-699190 priceSiemens BPZ:599-699190 quotebuy Siemens BPZ:599-699190BPZ:599-699190 priceBPZ:599-699190 stock availabilitySiemens spare partsSiemens BPZ:599-699190 equivalentSiemens BPZ:599-699190 specifications