FCM-6 - Fan Control Switch Module (6 Switches). Designed for use in a Siemens Modular (or FireFinder XLS) fire-alarm control panel, Model FCM-6 is an option module that provides manual control of building HVAC system fans, motors, and dampers. Each FCM-6 module provides six (6) sets of three (3) push-button switches for manual system control. Each switch has three (3) associated LEDs to indicate Fan / Damper / Motor status: OFF (Red LED); ON (Green LED) and TROUBLE (Yellow LED). When in the automatic position, the red and green LEDs indicate Fan / Damper / Motor status (On or Off) based on the system logic that can be programmed to automatically control the fan outputs. When manually switched to the OFF position, the red LED will flash indicating that the output circuit used to turn off the Fan / Damper / Motor has activated. The red LED will light solid-red to indicate positive feedback of the Fan / Damper / Motor actually turning OFF (via a monitored input). When manually switched to the ON position, the green LED will flash indicating that the output circuit used to turn on the Fan / Damper / Motor has activated. The green LED will light solid green to indicate positive feedback of the Fan / Damper / Motor actually turning on (via a monitored input). During system reset when switches are turned manually to the ON or the OFF position their associated outputs do not change state. They stay either ON or OFF based on the switch’s position. Outputs will only change state when manually controlled via the ON / OFF switch or based on system logic when switch is in the Auto position. Each Model FCM-6 is mounted on a hinged panel as a part of the Siemens Modular (or FireFinder XLS) command-console enclosure. Any combination of a Model SCM-8, LCM-8 or a FCM-6 module may be mounted on a Model ID-MP. A six (6) conductor cable is supplied for interconnection of the modules. A 30-inch cable (CCL) is available for connection between rows. Models SCM-8, LCM-8, and FCM-6 can be remotely mounted up to 1000 feet (304.8 m.) from the main enclosure. Models REMBOX2 and REMBOX4 lobby enclosures are required for remote mounting of Model SCM-8, LCM-8 and FCM-6. A Model CSB sounder is optionally available for switch audible feedback for remote mounting applications.
FCM-6 - Fan Control Switch Module (6 Switches). Designed for use in a Siemens Modular (or FireFinder XLS) fire-alarm control panel, Model FCM-6 is an option module that provides manual control of building HVAC system fans, motors, and dampers. Each FCM-6 module provides six (6) sets of three (3) push-button switches for manual system control. Each switch has three (3) associated LEDs to indicate Fan / Damper / Motor status: OFF (Red LED); ON (Green LED) and TROUBLE (Yellow LED). When in the automatic position, the red and green LEDs indicate Fan / Damper / Motor status (On or Off) based on the system logic that can be programmed to automatically control the fan outputs. When manually switched to the OFF position, the red LED will flash indicating that the output circuit used to turn off the Fan / Damper / Motor has activated. The red LED will light solid-red to indicate positive feedback of the Fan / Damper / Motor actually turning OFF (via a monitored input). When manually switched to the ON position, the green LED will flash indicating that the output circuit used to turn on the Fan / Damper / Motor has activated. The green LED will light solid green to indicate positive feedback of the Fan / Damper / Motor actually turning on (via a monitored input). During system reset when switches are turned manually to the ON or the OFF position their associated outputs do not change state. They stay either ON or OFF based on the switch’s position. Outputs will only change state when manually controlled via the ON / OFF switch or based on system logic when switch is in the Auto position. Each Model FCM-6 is mounted on a hinged panel as a part of the Siemens Modular (or FireFinder XLS) command-console enclosure. Any combination of a Model SCM-8, LCM-8 or a FCM-6 module may be mounted on a Model ID-MP. A six (6) conductor cable is supplied for interconnection of the modules. A 30-inch cable (CCL) is available for connection between rows. Models SCM-8, LCM-8, and FCM-6 can be remotely mounted up to 1000 feet (304.8 m.) from the main enclosure. Models REMBOX2 and REMBOX4 lobby enclosures are required for remote mounting of Model SCM-8, LCM-8 and FCM-6. A Model CSB sounder is optionally available for switch audible feedback for remote mounting applications.

Siemens
MFR #410455828
SKU #YLSL5RI1TVEAXYN

Siemens
MFR #500-019614
SKU #YLSLWCTJNEBHGM

Siemens
MFR #500-688977
SKU #YLSIOUQOSOIRZHE

Siemens
MFR #5WG1125-1AB13
SKU #YLSTYMOKKXUB0

Siemens
MFR #5WG1125-1AB23
SKU #YLSLERTZCFLXF0P

Siemens
MFR #5WG1125-4CB33
SKU #YLSW0XGZCPXHCDE

Siemens
MFR #5WG1141-1AB14
SKU #YLSVGXP12BHBWLH

Siemens
MFR #5WG1141-1AB32
SKU #YLSY0VBN7VTSVY

Siemens
MFR #5WG1146-1AB03
SKU #YLSAGHWH4KDB30E

Siemens
MFR #5WG1148-1AB23
SKU #YLSLJIXSIVM1Y

SMC
MFR #VQC2101R-51
SKU #YLSSEY6NT0YLZ8G

Baldor
MFR #VFSWDM3546T-5E
SKU #YLSRYYEFOOW6J5E

SMC
MFR #AL30-03-8-A
SKU #YLS6GDABZE4BN7A

SMC
MFR #NCDGFN25-0100
SKU #YLST0TDV975HLIN

SMC
MFR #VQZ2121-5LO1-N3T
SKU #YLSEL35MGGQ9FOL

SMC
MFR #NCDMC150-0600-X155US
SKU #YLS8ICKGSKYC93L

SMC
MFR #VQ1200-51-Q
SKU #YLSOVA6N31QD04G

SMC
MFR #CDJ2L16-125Z-B
SKU #YLS5V0RW2VJJR1A

SMC
MFR #AC20A-01G-V-1-B FR/L COMBO MODULAR
SKU #YLSSMWXCWLO2KA6

SMC
MFR #AW20-N02CG-6CZ-B
SKU #YLSNOOF0IBCZ3J3
Siemens BPZ:500-033140 priceSiemens BPZ:500-033140 quotebuy Siemens BPZ:500-033140BPZ:500-033140 priceBPZ:500-033140 stock availabilitySiemens spare partsSiemens BPZ:500-033140 equivalentSiemens BPZ:500-033140 specifications