Cookie Notice

We use cookies on our website to provide you with a better experience. Cookies are used to improve site performance, personalize content, and analyze traffic.

Siemens 7KM4212-0BA00-2AA0

Photo may not represent actual item. Refer to name and product specs for all details.

Siemens 7KM4212-0BA00-2AA0

SENTRON, measuring device, 7KM PAC4200, LCD, L-L: 690 V, L-N: 400 V, 5 A, 3-phase, Modbus TCP, optionally Modbus RTU / PROFINET / PROFIBUS / DI/DQ, apparent / active / reactive energy / cos phi, harmonics: 2nd - 64th, THD, Class 0.2 acc. to IEC 61557-12 or Class 0.2 s acc. to IEC 62053-22, wide-range power supply 95 to 240 V +-10% (AC), 110 to 340 V +-10% (DC) ring cable lug connection

SiemensMFR # 7KM4212-0BA00-2AA0SKU # CEY-8EF3B02EE827
product brand nameSENTRON
design of the productcompact
product type designation7KM PAC4200
for voltage measurementTRMS
for current measurementTRMS
type of measured value detectioncomplete
Share

About This Product

SENTRON, measuring device, 7KM PAC4200, LCD, L-L: 690 V, L-N: 400 V, 5 A, 3-phase, Modbus TCP, optionally Modbus RTU / PROFINET / PROFIBUS / DI/DQ, apparent / active / reactive energy / cos phi, harmonics: 2nd - 64th, THD, Class 0.2 acc. to IEC 61557-12 or Class 0.2 s acc. to IEC 62053-22, wide-range power supply 95 to 240 V +-10% (AC), 110 to 340 V +-10% (DC) ring cable lug connection

Siemens 7KM4212-0BA00-2AA0

  • Genuine, certified Siemens product
  • Fast sourcing through a worldwide supply network
  • Product selection and compatibility support from our technical team
  • Equivalent and alternative product suggestions
  • Quotation and lead time tailored to your request

Specifications

Model
product brand nameSENTRON
product designationMeasuring device for power system quality measurement
design of the productcompact
product type designation7KM PAC4200
Measurements
for voltage measurementTRMS
for current measurementTRMS
type of measured value detectioncomplete
voltage curveSinusoidal or distorted
initial value45 Hz
full-scale value65 Hz
operating mode for measured value detection automatic line frequency detectionYes
set at 50 HzNo
set to 60 HzNo
Supply voltage
design of the power supplyWide-range power supply
type of voltage of the supply voltageAC/DC
supply voltage at AC95 ... 240 V
supply voltage at DC110 ... 340 V
Degree of protection protection class
protection class IP on the frontIP65
operating resource protection class when installedII
Suitability
suitability for operationInstallation in stationary panels in closed rooms
Product Functions
voltage measurementYes
current measurementYes
active power measurementYes
reactive power measurementYes
frequency measurementYes
Display and operation
design of the displayLCD
height of the display54 mm
width of the display72 mm
color of the background of the displaywhite
illuminance of display backlight adjustableYes
time-controlled reduction of the illuminance of display backlight possibleYes
display contrast adjustableYes
national language on the display screen is supportedger, en, fr, spa, ita, por, tur, rus, chi, pol
number of keys4
Communication
transfer rate minimum10 000 kbit/s
transfer rate maximum100 000 kbit/s
number of interfaces according to Fast Ethernet1
type of electrical connection of the fast Ethernet interfaceRJ45 (8P8C)
protocol at the Ethernet interface is supportedMODBUS TCP
transfer rate 1 for Ethernet10 Mbit/s
transfer rate 2 for Ethernet100 Mbit/s
Fault limits
reference condition for metering accuracyaccording to IEC61557-12
for measured variable voltage+/- 0.2 %
for measured variable current+/- 0.2 %
for measured variable output factor+/- 2 %
for measured variable active energyClass 0.2 according to IEC61557-12 and/or class 0.2S according to IEC62053-22
for measured variable reactive energyClass 2 according to IEC61557-12 and/or IEC62053-23
for measured variable THD+/- 2 %
Inputs Outputs
number of digital inputs2
type of electrical connection at the digital inputsscrew-type terminals
operating conditions for digital inputs external voltage supplyYes
input voltage at digital input at DC maximum30 V
number of digital outputs2
type of switching outputsolid state
digital output versionswitching or pulse output function
operating voltage as output voltage at DC maximum permissible30 V
type of electrical connection at the digital outputsscrew-type terminals
at digital output with signal <0> maximum0.2 mA
at digital output for signal <1> maximum27 mA
at the digital outputs at DC limited to 100 ms maximum300 mA
internal resistance at the digital outputs55 Ω
standard for pulse emitteraccording to IEC62053-31
initial value30 ms
full-scale value500 ms
adjustable time period minimum10 ms
switching frequency at digital output maximum20 Hz
property of the output short-circuit proofYes
measuring category for digital signalsCATI
Measuring inputs
measurable supply voltage between (PE)N and L at AC maximum rated value400 V
minimum11.5 V
maximum480 V
measurable supply voltage between the line conductors at AC maximum rated value690 V
minimum20 V
maximum828 V
voltage measuring range extension with external voltage transformersyes
line conductors and neutral conductors internal resistance for voltage measurement1.05 MΩ
measuring category for voltage measurementCAT III
1 at AC rated value1 A
2 at AC rated value5 A
minimum10 %
maximum120 %
current measuring range extension with external current transformersYes
zero point suppression for current measurement0 ... 10 %
with measuring range 1 A per phase4 mVA
with measuring range 5 A per phase0.115 V·A
measuring category for current measurementCATIII
Connections
at the measurement inputs for voltageRing cable lug connection
Mechanical Design
fastening method DIN-rail mountingNo
size of Power Monitoring Devicesize 96
height96 mm
width96 mm
depth82 mm
installation depth77 mm
mounting positionvertical
Environmental conditions
minimum-10 °C
maximum55 °C
minimum-25 °C
maximum70 °C
relative humidity at 25 °C without condensation during operation maximum95 %
installation altitude at height above sea level maximum2 000 m
degree of pollution2
Certificates
certificate of suitability as EC Declaration of ConformityIEC 61010-1: 2001 (2nd Ed.) with Corr. 1, EN 61010-1: 2001 (2nd Ed.) and DIN EN 61010-1:2002 with "Berichtigung 1"

Accessories 10

Genuine accessories that can be used with the Siemens 7KM4212-0BA00-2AA0 motor and are supplied separately are listed below. Click a code to open the accessory page and see the other compatible motors.

Related Products

3KA7111-3AA00
Siemens 3KA7111-3AA00
View Details

Siemens

3KA7111-3AA00

MFR #3KA7111-3AA00

SKU #YLS84GJV5GBLKJH

2GP1801-0GA20-0YA2
View Details

Siemens

2GP1801-0GA20-0YA2

MFR #2GP1801-0GA20-0YA2

SKU #YLSBHJPOPJUTI9U

2GP1801-0GA20-0YH2
View Details

Siemens

2GP1801-0GA20-0YH2

MFR #2GP1801-0GA20-0YH2

SKU #YLS3T9IJR4HLBF0

2GP1801-0GA20-0YP2
View Details

Siemens

2GP1801-0GA20-0YP2

MFR #2GP1801-0GA20-0YP2

SKU #YLSH9JPFGKDJP1O

2GP1801-0GA20-0YU2
View Details

Siemens

2GP1801-0GA20-0YU2

MFR #2GP1801-0GA20-0YU2

SKU #YLSIZVE1RW1YKKK

3KA7111-4AA00
View Details

Siemens

3KA7111-4AA00

MFR #3KA7111-4AA00

SKU #YLSVT2LBV16HK1Z

3KA7112-3AA00
View Details

Siemens

3KA7112-3AA00

MFR #3KA7112-3AA00

SKU #YLSRU54ONYJV7WO

3KA7112-4AA00
View Details

Siemens

3KA7112-4AA00

MFR #3KA7112-4AA00

SKU #YLSJUQIYQBUL0TA

3KA7113-3AA00
View Details

Siemens

3KA7113-3AA00

MFR #3KA7113-3AA00

SKU #YLSXFRETT4MZVS7

3KA7113-4AA00
View Details

Siemens

3KA7113-4AA00

MFR #3KA7113-4AA00

SKU #YLSEMXSJ3VUUMEP

Featured Products

VQ1200-51-Q
SMC VQ1200-51-Q
View Details

SMC

VQ1200-51-Q

MFR #VQ1200-51-Q

SKU #YLSOVA6N31QD04G

VQC2101R-51
SMC VQC2101R-51
View Details

SMC

VQC2101R-51

MFR #VQC2101R-51

SKU #YLSSEY6NT0YLZ8G

BC8M12
Brush Research Mfg BC8M12
View Details

Brush Research Mfg

BC8M12

MFR #BC8M12

SKU #YLSA0P5BE6ZJCIW

AW20-N02CG-6CZ-B
SMC AW20-N02CG-6CZ-B
View Details

SMC

AW20-N02CG-6CZ-B

MFR #AW20-N02CG-6CZ-B

SKU #YLSNOOF0IBCZ3J3

MXQ25L-40B-M9NZ
SMC MXQ25L-40B-M9NZ
View Details

SMC

MXQ25L-40B-M9NZ

MFR #MXQ25L-40B-M9NZ

SKU #YLSD1VANMRI726Z

MDBB63-100Z
SMC MDBB63-100Z
View Details

SMC

MDBB63-100Z

MFR #MDBB63-100Z

SKU #YLSNBPQBGLI90UX

MXQ25-40B-M9NZ
SMC MXQ25-40B-M9NZ
View Details

SMC

MXQ25-40B-M9NZ

MFR #MXQ25-40B-M9NZ

SKU #YLST5TX9LNATRNS

VM8001-5
Baldor VM8001-5
View Details

Baldor

VM8001-5

MFR #VM8001-5

SKU #YLS3TOWVXWW0DHP

Related Searches

Siemens 7KM4212-0BA00-2AA0 priceSiemens 7KM4212-0BA00-2AA0 quotebuy Siemens 7KM4212-0BA00-2AA07KM4212-0BA00-2AA0 price7KM4212-0BA00-2AA0 stock availabilitySiemens spare partsSiemens 7KM4212-0BA00-2AA0 equivalentSiemens 7KM4212-0BA00-2AA0 specifications