General information
Product type designationCFU CIO HART
HW functional statusFS01
Firmware versionV1.0
FW update possibleYes
Vendor identification (VendorID)002AH
Device identifier (DeviceID)0319H
Number of channels16
Product function
I&M dataYes; I&M0 to I&M3
Isochronous modeNo
The user can configure digital channels as input/output as requiredYes
Digital channels can be parameterizedYes
Engineering with
STEP 7 TIA Portal configurable/integrated from versionV19 Update 2
STEP 7 configurable/integrated from versionSTEP 7 V5.7.1.4
PCS 7 configurable/integrated from versionV9.1 SP2 UC7 (+PDM V9.3 Upd1)
PROFIBUS from GSD version/GSD revision- / -
PROFINET from GSD version/GSD revisionGSDML V2.43 2024.03.04
Operating mode
DIYes
CounterYes
DQYes
CiR - Configuration in RUN
Reparameterization possible in RUNYes
Installation type/mounting
Mountingon 35 mm DIN rail, 2 spacing units wide
Mounting positionHorizontal, vertical
Recommended mounting positionhorizontal set up
Supply voltage
Type of supply voltage24 V DC
Rated value (DC)24 V
permissible range, lower limit (DC)19.2 V
permissible range, upper limit (DC)28.8 V
Reverse polarity protectionYes
Short-circuit protectionYes
redundant power supplyYes
Mains buffering
Mains/voltage failure stored energy time1 ms; For communication
Input current
Current consumption (rated value)4.1 A; RJ45 BusAdapter, 8xDI, 4xAI, 2xAQ, 2xDQ with 2 A each
Current consumption, max.9 A
Inrush current, max.7 A
I²t0.5 A²·s
Encoder supply
Number of outputs16
Output voltage, min.12 V
Short-circuit protectionYes; Electronic
Output current
up to 60 °C, max.8 A; total current DQ + additional current for analog channels
up to 70 °C, max.6 A; total current DQ + additional current for analog channels
Power loss
Power loss, typ.6.6 W; RJ45 BusAdapter, 8xDI, 4xAI, 2xAQ, 2xDQ with 12 ohms load each
Address space per station
Address space per station, max.1 440 byte; Dependent on configuration
Digital inputs
Number of digital inputs16
Digital inputs, parameterizableYes
Sourcing/sinking inputYes
Input characteristic curve in accordance with IEC 61131, type 1Yes
Input characteristic curve in accordance with IEC 61131, type 2No
Input characteristic curve in accordance with IEC 61131, type 3Yes
Pulse extensionYes; off, 50 ms, 100 ms, 200 ms, 500 ms, 1 s, 2 s
Digital input functions, parameterizable
Gate start/stopYes; hardware gate, usable by multiple DI counters
Freely usable digital inputYes; Parameterizable input filter
CounterYes
— Number, max.16
— Counting frequency, max.5 kHz; fast counter mode, sinking input; 1 kHz sourcing input, NAMUR
— Counting width32 bit
— Counting direction up/downYes; Up
Input voltage
Rated value (DC)24 V
for signal "0"-9 V to +5 V
for signal "1"+11 to +30V
permissible voltage at input, min.-9 V
permissible voltage at input, max.30 V
Input current
for signal "1", typ.2.5 mA; max: 2.5 mA sourcing input; 2.3 mA sinking input; 10 mA fast counter; 6.5 mA NAMUR
for standard inputs
— parameterizableYes; none / 0.05 / 0.1 / 0.2 / 0.4 / 0.8 / 1.6 / 3.2 / 12.8 / 20 ms
Cable length
shielded, max.1 000 m
unshielded, max.600 m
Digital outputs
Type of digital outputTransistor
Number of digital outputs16
Current-sinkingNo
Current-sourcingYes
Short-circuit protectionYes
Response threshold, typ.4.1 A
Open-circuit detectionYes
Overload protectionYes
Limitation of inductive shutdown voltage totyp. L+ (-11 V)
Controlling a digital inputYes
Switching capacity of the outputs
with resistive load, max.2 A
on lamp load, max.5 W
Load resistance range
lower limit12 Ω
upper limit12 kΩ
Output voltage
Type of output voltageDC
for signal "1", min.Ue minus 1 V
Output current
for signal "1" rated value2 A
for signal "0" residual current, max.0.1 mA
Output delay with resistive load
"0" to "1", typ.50 µs
"0" to "1", max.100 µs
"1" to "0", typ.50 µs
"1" to "0", max.100 µs
Parallel switching of two outputs
for upratingNo
for redundant control of a loadNo
Switching frequency
with resistive load, max.100 Hz
with inductive load, max.1 Hz; at 2 A; 2 Hz at 0.5 A
on lamp load, max.10 Hz
Total current of the outputs
Current per channel, max.2 A
horizontal installation
— up to 60 °C, max.8 A
— up to 70 °C, max.6 A
vertical installation
— up to 60 °C, max.8 A
— up to 70 °C, max.6 A
Cable length
shielded, max.1 000 m
unshielded, max.600 m
Analog inputs
Number of analog inputs16
Input ranges
CurrentYes; 0 ... 20 mA, 4 ... 20 mA, 4 ... 20 mA HART
Input ranges (rated values), currents
0 to 20 mAYes; 16 bit incl. sign
— Input resistance (0 to 20 mA)233 Ω
4 mA to 20 mAYes; 16 bit incl. sign
— Input resistance (4 mA to 20 mA)233 Ω
HART communication
Primary MasterYes
input resistance (with HART communication)233 Ω
Cable length
shielded, max.1 000 m
unshielded, max.600 m
Analog outputs
Number of analog outputs16; short-circuit proof with respect to ground
Current output, no-load voltage, max.24 V
Output ranges, current
0 to 20 mAYes; 15 bit
-20 mA to +20 mANo
4 mA to 20 mAYes; 16 bit incl. sign
Connection of actuators
for current output two-wire connectionYes
Load impedance (in rated range of output)
for current outputs, min.50 Ω
with current outputs, max.750 Ω
with current outputs, inductive load, max.10 mH
Destruction limits against externally applied voltages and currents
Voltages at the outputs36 V; Minus 0.3 V lower limit
Cable length
shielded, max.1 000 m
unshielded, max.600 m
Analog value generation for the inputs
Measurement principleintegrating (Sigma-Delta)
Integration and conversion time/resolution per channel
Resolution with overrange (bit including sign), max.16 bit
Integration time, parameterizableYes; channel by channel
Smoothing of measured values
parameterizableYes; none, weak, medium, strong, channel-by-channel
Settling time
for resistive load2 ms; 750 ohm
for inductive load1.2 ms
Connection of signal encoders
for current measurement as 2-wire transducerYes
Connectable encoders
NAMUR encoder/changeover contact according to EN 60947Yes; no CO contact
2-wire sensorYes
— permissible quiescent current (2-wire sensor), max.1.5 mA
Errors/accuracies
Linearity error (relative to input range), (+/-)0.05 %
Temperature error (relative to input range), (+/-)0.005 %/K
Crosstalk between the inputs, min.60 dB
Repeat accuracy in steady state at 25 °C (relative to input range), (+/-)0.05 %
Linearity error (relative to output range), (+/-)0.02 %
Temperature error (relative to output range), (+/-)0.003 %/K
Crosstalk between the outputs, min.70 dB
Repeat accuracy in steady state at 25 °C (relative to output range), (+/-)0.02 %
Operational error limit in overall temperature range
Current, relative to input range, (+/-)0.5 %
Current, relative to output range, (+/-)0.5 %; 0 ... 60 °C: 0.2 %
Basic error limit (operational limit at 25 °C)
Current, relative to input range, (+/-)0.1 %
Current, relative to output range, (+/-)0.1 %
Interfaces
Number of PROFINET interfaces1
1. Interface
Interface typePROFINET
IsolatedYes
Interface types
Number of ports2; via BusAdapter
integrated switchYes
BusAdapter (PROFINET)Yes
Protocols
PROFINET IO DeviceYes
Media redundancyYes; as MRP client
RJ 45 (Ethernet)
100 MbpsYes
AutonegotiationYes
AutocrossingYes
Protocols
Supports protocol for PROFINET IOYes
HART protocolYes
Protocol versionup to Revision 7
Redundancy mode
PROFINET system redundancy (S2)Yes; Type S2
Media redundancy
— MRPYes
Open IE communication
LLDPYes
Interrupts/diagnostics/status information
Status indicatorYes
AlarmsYes
Diagnostics functionYes
Substitute values connectableYes
Alarms
Diagnostic alarmYes
Maintenance interruptYes
Limit value alarmYes
Hardware interruptYes
Diagnoses
Monitoring the supply voltageYes
Wire breakYes; channel by channel
Short-circuitYes; channel by channel
Group errorYes
Overflow/UnderflowYes; channel by channel
Diagnostics indication LED
RUN LEDYes; green LED
ERROR LEDYes; red LED
MAINT LEDYes; Yellow LED
Monitoring of the supply voltage (PWR-LED)Yes; green/red LED
Channel status displayYes; green/red LED
Status indicator digital input (green)Yes
Status indicator digital output (green)Yes
Connection display LINK TX/RXYes; 2x green link LEDs on BusAdapter
Integrated Functions
Frequency measurementYes
Number of frequency meters16
Counting functions
Continuous countingYes
Counter response parameterizableYes
Hardware gate via digital inputYes
Software gateYes
Measuring functions
Dynamic measurement period adjustmentYes
Measuring range
— Frequency measurement, min.0.1 Hz
— Frequency measurement, max.25 kHz; fast counter mode, sinking input; 1 kHz sourcing input, NAMUR
Accuracy
— Frequency measurement100 ppm; depending on measuring interval and signal evaluation
Potential separation digital inputs
between the channelsNo
between the channels and the power supply of the electronicsNo
Potential separation digital outputs
between the channelsNo
between the channels and the power supply of the electronicsNo
Isolation
Isolation tested with1 500 V AC between PROFINET and other electronics
Degree and class of protection
IP degree of protectionIP20
Ambient temperature during operation
horizontal installation, min.-40 °C
horizontal installation, max.70 °C; Observe derating
vertical installation, min.-40 °C
vertical installation, max.70 °C; Observe derating
Ambient temperature during storage/transportation
min.-40 °C
max.70 °C
Relative humidity
Operation, max.95 %
Connection method
Design of electrical connectionConnection plug
Dimensions
Width329 mm
Height123 mm
Depth74 mm
Weights
Weight, approx.0.7 kg