Cookie Notice

We use cookies on our website to provide you with a better experience. Cookies are used to improve site performance, personalize content, and analyze traffic.

Siemens 6ES7615-7DF10-0AB0

Photo may not represent actual item. Refer to name and product specs for all details.

Siemens 6ES7615-7DF10-0AB0

SIMATIC S7-1500, Drive Controller CPU 1507D TF with SINAMICS S120 Integrated; interfaces: 12 DI, 16 DI/DQ, 4 DRIVE-CLiQ, 3 PROFINET: 3+1+1 ports, 1 PROFIBUS, SIMATIC Memory Card required; supported firmware version: SIMATIC S7-1500 FW up to V3.1 (technology version up to V8.0), SINAMICS FW V5.2/V5.2 SP3

SiemensMFR # 6ES7615-7DF10-0AB0SKU # YLSWOW4OLRWGT6U
Product type designationCPU 1507D TF
HW functional statusFS13
based onSIMATIC S7-1500 TF-CPU and SINAMICS S120
I&M dataYes; I&M0 to I&M3
Isochronous modeYes; with minimum OB 6x cycle of 250 µs
SysLogYes
Share

About This Product

SIMATIC S7-1500, Drive Controller CPU 1507D TF with SINAMICS S120 Integrated; interfaces: 12 DI, 16 DI/DQ, 4 DRIVE-CLiQ, 3 PROFINET: 3+1+1 ports, 1 PROFIBUS, SIMATIC Memory Card required; supported firmware version: SIMATIC S7-1500 FW up to V3.1 (technology version up to V8.0), SINAMICS FW V5.2/V5.2 SP3

Siemens 6ES7615-7DF10-0AB0

  • Genuine, certified Siemens product
  • Fast sourcing through a worldwide supply network
  • Product selection and compatibility support from our technical team
  • Equivalent and alternative product suggestions
  • Quotation and lead time tailored to your request

Specifications

General information
Product type designationCPU 1507D TF
HW functional statusFS13
Firmware versionPLC: V3.1 / SINAMICS Integrated: V5.2 SP3
FW update possibleYes; PLC up to V3.1 / SINAMICS Integrated up to V5.2 SP3
based onSIMATIC S7-1500 TF-CPU and SINAMICS S120
Product function
I&M dataYes; I&M0 to I&M3
Isochronous modeYes; with minimum OB 6x cycle of 250 µs
SysLogYes
Engineering with
STEP 7 TIA Portal configurable/integrated from versionV21 (FW V3.1) / V16 (FW V2.8) or higher
Integrated drive control
Number of axes for servo control, max.6
Number of axes for vector control, max.6
Number of axes for V/f control, max.12
Remarkalternative control modes; drive control based on SINAMICS S120 CU320-2 (firmware version V5.x); functional subset compared to CU320-2: no free function blocks, ... ; for details, see the manual
Configuration control
via datasetYes
Control elements
Number of keys1; FUNCT button
Mode selector switch1
Supply voltage
Rated value (DC)24 V
permissible range, lower limit (DC)20.4 V
permissible range, upper limit (DC)28.8 V
Reverse polarity protectionYes
Mains buffering
Mains/voltage failure stored energy time3 ms; Refers to the power supply on the CPU section
Repeat rate, min.1 event every 10 s
Input current
Current consumption (rated value)0.65 A; Without load on inputs/outputs, without supply via DRIVE- CLiQ/USB interface
Current consumption, max.13.1 A; With load
Inrush current, max.6 A; Rated value
I²t0.62 A²·s
Power loss
Power loss, typ.17 W
Storage
Number of slots for SIMATIC memory card1
SIMATIC memory card requiredYes
Work memory
integrated (for program)15 Mbyte
integrated (for data)40 Mbyte
Load memory
Plug-in (SIMATIC Memory Card), required12 Mbyte; Recommended at least when integrated drive is used
Plug-in (SIMATIC Memory Card), max.32 Gbyte
Backup
maintenance-freeYes
CPU-blocks
Number of elements (total)20 000; Blocks (OB, FB, FC, DB) and UDTs
DB
Number range1 ... 60 999; subdivided into: number range that can be used by the user: 1 ... 59 999, and number range of DBs created via SFC 86: 60 000 ... 60 999
Size, max.16 Mbyte; For DBs with absolute addressing, the max. size is 64 KB
FB
Number range0 ... 65 535
Size, max.1 Mbyte
FC
Number range0 ... 65 535
Size, max.1 Mbyte
OB
Size, max.1 Mbyte
Number of free cycle OBs100
Number of time alarm OBs20
Number of delay alarm OBs20
Number of cyclic interrupt OBs20; with minimum OB 3x cycle of 100 µs
Number of process alarm OBs50
Number of DPV1 alarm OBs3
Number of isochronous mode OBs3
Number of technology synchronous alarm OBs2
Number of startup OBs100
Number of asynchronous error OBs4
Number of synchronous error OBs2
Number of diagnostic alarm OBs1
Nesting depth
per priority class24; Up to 8 possible for F-blocks
S7 counter
Number2 048
Retentivity
— adjustableYes
IEC counter
NumberAny (only limited by the main memory)
Retentivity
— adjustableYes
S7 timer
Number2 048
Retentivity
— adjustableYes
IEC timer
NumberAny (only limited by the main memory)
Retentivity
— can be setYes
Data areas and their retentivity
Retentive data area (incl. timers, counters, flags), max.700 kbyte; in total; for bit memories, timers, counters, DBs, and technology data (axes)
Flag
Size, max.16 kbyte
Number of clock memories8; 8 clock memory bit, grouped into one clock memory byte
Data blocks
Retentivity adjustableYes
Retentivity presetNo
Local data
per priority class, max.64 kbyte; max. 16 KB per block
Address area
Number of IO modules16 384; max. number of modules / submodules
I/O address area
Inputs32 kbyte; All inputs are in the process image
Outputs32 kbyte; All outputs are in the process image
per integrated IO subsystem
— Inputs (volume)32 kbyte; Max. 32 KB via X150; max. 8 KB via X160 or X126
— Outputs (volume)32 kbyte; Max. 32 KB via X150; max. 8 KB via X160 or X126
Subprocess images
Number of subprocess images, max.32
Hardware configuration
Number of distributed IO systems64; A distributed I/O system is characterized not only by the integration of distributed I/O via PROFINET or PROFIBUS, but also by the connection of I/O via AS-i master modules or links (e.g. IE/PB-Link)
Number of DP masters
integrated1
Via CMExpansion via CMs / CPs (PROFIBUS, PROFINET, Ethernet) not possible; these CMs / CPs can only be operated in a central rack
Number of IO Controllers
Integrated2
via CMExpansion via CMs / CPs (PROFIBUS, PROFINET, Ethernet) not possible; these CMs / CPs can only be operated in a central rack
PtP CM
Number of PtP CMsThe number of connectable PtP CMs (distributed) is only limited by the number of available slots
Clock
TypeHardware clock
Backup time6 wk; At 40 °C ambient temperature, typically
Deviation per day, max.10 s; Typ.: 2.4 s
Operating hours counter
Number16
Clock synchronization
supportedYes
to DP, masterYes
on DP, deviceYes
in AS, masterYes
in AS, deviceYes
on Ethernet via NTPYes
Digital inputs
integrated channels (DI)28; max. depending on parameterization
Digital inputs, parameterizableYes; 12 DI, 8 DI/DQ (X122/X132, SINAMICS Integrated) + 8 DI/DQ (X142, PLC)
Sourcing/sinking inputP-reading
Input characteristic curve in accordance with IEC 61131, type 3Yes
Digital input functions, parameterizable
Freely usable digital inputYes; Max. 20 (X122/X132) + max. 8 (X142)
ProbeYes; Max. 8 (X122/X132) + max. 8 (X142)
Digital input with time stampYes; Max. 8 (X142); e.g. for probes
CounterYes; Max. 8 (X142); event/cycle duration measurement
Digital input with oversamplingYes; Max. 8 (X142); 32-fold oversampling
Input voltage
Type of input voltageDC
Rated value (DC)24 V
for signal "0"-3 to +5V
for signal "1"+11 to +30V
permissible voltage at input, min.-3 V
permissible voltage at input, max.30 V
Input current
for signal "1", typ.4 mA
Input delay (for rated value of input voltage)
Minimum pulse width for program reactions5 µs; for X122/X132/X142 (DI/DQ as DI; for X142 with filter setting 1 µs)
for standard inputs
— parameterizableNo; For X122/X132
— with "0" to "1", typ.For X122/X132: 10 µs (DI) / 5 µs (DI/DQ as DI)
— with "1" to "0", typ.For X122/X132: 30 µs (DI) / 5 µs (DI/DQ as DI)
for interrupt inputs
— ParameterizableYes; identical to those for technological functions
for technological functions
— ParameterizableYes; For X142, additionally adjustable input filter: 1 µs / 125 µs
— with "0" to "1", typ.5 µs; For X142; HW delay
— with "1" to "0", typ.5 µs; For X142; HW delay
Cable length
shielded, max.30 m; For technological functions: Shielding of the DI recommended depending on the requirements
unshielded, max.30 m
Digital outputs
Type of digital outputTransistor
integrated channels (DO)16; max. depending on parameterization
Current-sinkingYes; With High Speed output
Current-sourcingYes; Optionally as a P-switch or high-speed push-pull switch (high-speed output)
Digital outputs, parameterizableYes; 8 DI/DQ (X122/X132, SINAMICS Integrated) + 8 DI/DQ (X142, PLC)
Short-circuit protectionYes; electronic/thermal
Response threshold, typ.X122/X132: 1.4 A / X142: 0.9 A (high-speed output: 0.7 A)
Limitation of inductive shutdown voltage toX122/X132: max. -60 V / X142: max. -64.5 V
Controlling a digital inputYes
minimum pulse duration2 µs; For high-speed output, single pulse
Digital output functions, parameterizable
Freely usable digital outputYes; Max. 8 (X122/X132) + max. 8 (X142)
Digital output with time stampYes; Max. 8 (X142); e.g. for output cams
PWM outputYes; Max. 8 (X142)
— Cycle duration, parameterizableYes; Base frequency 1 / 2 / 4 / 8 / 16 kHz; specification of interpulse period ratio over 32-bit pattern
— ON period, min.0 %
— ON period, max.100 %
— Resolution of the duty cycle3.125 %
Digital output with oversamplingYes; Max. 8 (X142)
Switching capacity of the outputs
with resistive load, max.0.5 A; 0.4 A for high-speed output
on lamp load, max.5 W
Load resistance range
lower limit48 Ω; with 24 V DC supply
Output voltage
Type of output voltageDC
Rated value (DC)24 V
for signal "0", max.28.8 V
for signal "1", min.20.4 V
Output current
for signal "1" rated value0.5 A; 0.4 A for high-speed output
for signal "1" permissible range, min.2 mA
for signal "1" permissible range, max.0.6 A; 0.44 A for high-speed output
Output delay with resistive load
"0" to "1", typ.100 µs; For X122/X132; at 48 ohm load
"1" to "0", typ.150 µs; For X122/X132; at 48 ohm load
for technological functions
— "0" to "1", typ.1 µs; For X142
— "1" to "0", typ.1 µs; For X142 as a high-speed output; 150 µs for standard output
Parallel switching of two outputs
for logic linksYes; For technological functions and high-speed outputs: No
for upratingNo
for redundant control of a loadYes; For technological functions and high-speed outputs: No
Switching frequency
with resistive load, max.35 kHz; With High Speed output, 1 kHz with standard output
with inductive load, max.2 Hz; Max. 1 J per channel
on lamp load, max.11 Hz
Total current of the outputs
Current per module, max.8 A
Cable length
shielded, max.30 m
unshielded, max.30 m
Interfaces
Number of PROFINET interfaces3
Number of PROFIBUS interfaces1
Number of USB interfaces2; USB 3.0 (without function, no connection permissible)
Number of DRIVE-CLiQ interfaces4; DRIVE-CLiQ interfaces (24 V / 450 mA per interface for connecting encoders/measuring systems)
Interface types
RJ 45 (Ethernet)Yes; X150
Number of ports3
integrated switchYes
Protocols
IP protocolYes; IPv4
PROFINET IO ControllerYes
PROFINET IO deviceYes
SIMATIC communicationYes
Open IE communicationYes; Optionally also encrypted
Web serverYes
Media redundancyYes
Services
— Isochronous modeYes
— Direct data exchangeYes; Requirement: IRT and isochronous mode (MRPD optional)
— IRTYes
— Dynamic Frame Packing (DFP)Yes
— PROFIenergyYes; per user program
— Prioritized startupYes; Max. 32 PROFINET devices
— Number of connectable IO Devices, max.256; In total, up to 1 000 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET
— Of which IO devices with IRT, max.64
— Number of connectable IO Devices for RT, max.256
— of which in line, max.256
— Number of IO Devices that can be simultaneously activated/deactivated, max.8; in total across all interfaces
— Number of IO Devices per tool, max.8
— Updating timesThe minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data
— PROFINET Security Class1
Update time for IRT
— for send cycle of 250 µs250 µs to 4 ms
— for send cycle of 500 µs500 µs to 8 ms
— for send cycle of 1 ms1 ms to 16 ms
— for send cycle of 2 ms2 ms to 32 ms
— for send cycle of 4 ms4 ms to 64 ms
— With IRT and parameterization of "odd" send cyclesUpdate time = set "odd" send clock (any multiple of 125 µs: 375 µs, 625 µs ... 3 875 µs)
Update time for RT
— for send cycle of 250 µs250 µs to 128 ms
— for send cycle of 500 µs500 µs to 256 ms
— for send cycle of 1 ms1 ms to 512 ms
— for send cycle of 2 ms2 ms to 512 ms
— for send cycle of 4 ms4 ms to 512 ms
Services
— Isochronous modeNo
— IRTYes
— Dynamic Frame Packing (DFP)No
— PROFIenergyYes; per user program
— Prioritized startupNo
— Shared deviceYes
— Number of IO Controllers with shared device, max.4
— activation/deactivation of I-devicesYes; per user program
— Asset management recordYes; per user program
— PROFINET Security ClassSNMP Configuration and DCP Read Only
Interface types
RJ 45 (Ethernet)Yes; X160
Number of ports1
integrated switchNo
Protocols
IP protocolYes; IPv4
PROFINET IO ControllerYes
PROFINET IO DeviceYes
SIMATIC communicationYes
Open IE communicationYes; Optionally also encrypted
Web serverYes
Media redundancyNo
Services
— Isochronous modeNo
— Direct data exchangeNo
— IRTNo
— PROFIenergyYes; per user program
— Prioritized startupNo
— Number of connectable IO Devices, max.128; In total, up to 1 000 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET
— Number of connectable IO Devices for RT, max.128
— of which in line, max.128
— Number of IO Devices that can be simultaneously activated/deactivated, max.8; in total across all interfaces
— IO Devices changing during operation (partner ports), supportedYes
— Number of IO Devices per tool, max.8
— Updating timesThe minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data
— PROFINET Security Class1
Update time for RT
— for send cycle of 1 ms1 ms to 512 ms
Services
— Isochronous modeNo
— IRTNo
— PROFIenergyYes; per user program
— Prioritized startupNo
— Shared deviceYes
— Number of IO Controllers with shared device, max.4
— activation/deactivation of I-devicesYes; per user program
— Asset management recordYes; per user program
— PROFINET Security ClassSNMP Configuration and DCP Read Only
Interface types
RJ 45 (Ethernet)Yes; X130
Number of ports1
integrated switchNo
Protocols
IP protocolYes; IPv4
PROFINET IO ControllerNo
PROFINET IO deviceNo
SIMATIC communicationYes
Open IE communicationYes; Optionally also encrypted
Web serverYes
Interface types
RS 485Yes; X126
Number of ports1
Protocols
PROFIBUS DP masterYes
PROFIBUS DP deviceNo
SIMATIC communicationYes
PROFIBUS DP master
Number of connections, max.48; for the integrated PROFIBUS DP interface
max. number of DP devices125; In total, up to 1 000 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET
Services
— EquidistanceYes
— Isochronous modeYes
— activation/deactivation of DP devicesYes
RJ 45 (Ethernet)
100 MbpsYes
1000 MbpsYes; Only at the X130 interface
AutonegotiationYes
AutocrossingYes
Industrial Ethernet status LEDYes; LINK and ACTIVITY
RS 485
Transmission rate, max.12 Mbit/s
Protocols
PROFIsafeYes; V2.4 / V2.6 (V2.6 only with PROFINET)
Number of connections
Number of connections, max.384; Via integrated interfaces of the CPU
Number of connections reserved for ES/HMI/web10
Number of connections via integrated interfaces320
Number of S7 routing paths64; in total, only 16 S7-Routing connections are supported via PROFIBUS
Redundancy mode
PROFINET system redundancy (S2)No
PROFINET system redundancy (R1)No
H-Sync forwardingYes
Media redundancy
— Media redundancyonly via interface X150
— MRPYes; MRP Automanager according to IEC 62439-2 Edition 2.0, MRP Manager; MRP Client
— MRP interconnection, supportedYes; as MRP ring node according to IEC 62439-2 Edition 3.0
— MRPDYes; Requirement: IRT
— Switchover time on line break, typ.200 ms; For MRP, bumpless for MRPD
— Number of stations in the ring, max.50
SIMATIC communication
PG/OP communicationYes; encryption with TLS V1.3 pre-selected
S7 routingYes
Data record routingYes
S7 communication, as serverYes
S7 communication, as clientYes
User data per job, max.See online help (S7 communication, user data size)
Open IE communication
TCP/IPYes
— Data length, max.64 kbyte
— several passive connections per port, supportedYes
ISO-on-TCP (RFC1006)Yes
— Data length, max.64 kbyte
UDPYes
— Data length, max.2 kbyte; 1 472 bytes for UDP broadcast
— UDP multicastYes; 128 multicast circuits (of which max. 5 via X150)
DHCPYes
DNSYes
SNMPYes
DCPYes
LLDPYes
EncryptionYes; Optional
Web server
HTTPYes; Standard and user pages
HTTPSYes; Standard and user pages
— Number of sessions, max.200
— number of simultaneous HTTP calls, max.4
— HTTP request body, max.131 072 byte
OPC UA
Runtime license requiredYes; "Large" license required
OPC UA ClientYes; Data Access (registered Read/Write), Method Call
— Application authenticationYes
— Security policiesAvailable security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256
— User authentication"anonymous" or by user name & password
— Number of connections, max.40
— Number of nodes of the client interfaces, recommended max.5 000
— Number of elements for one call of OPC_UA_NodeGetHandleList/OPC_UA_ReadList/OPC_UA_WriteList, max.300
— Number of elements for one call of OPC_UA_NameSpaceGetIndexList, max.20
— Number of elements for one call of OPC_UA_MethodGetHandleList, max.100
— Number of simultaneous calls of the client instructions for session management, per connection, max.1
— Number of simultaneous calls of the client instructions for data access, per connection, max.5
— Number of registerable nodes, max.5 000
— Number of registerable method calls of OPC_UA_MethodCall, max.100
— Number of inputs/outputs when calling OPC_UA_MethodCall, max.20
OPC UA ServerYes; Data Access (Read, Write, Subscribe), Method Call, Alarms & Condition (A&C), Custom Address Space
— Application authenticationYes
— Security policiesavailable security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256, Aes128Sha256RsaOaep, Aes256Sha256RsaPss
— User authentication"anonymous" or by user name & password
— GDS support (certificate management)Yes
— Number of sessions, max.64
— Number of accessible variables, max.200 000
— Number of registerable nodes, max.50 000
— Number of subscriptions per session, max.50
— Sampling interval, min.10 ms
— Publishing interval, min.10 ms
— Number of server methods, max.100
— Number of inputs/outputs per server method, max.20
— Number of monitored items, recommended max.10 000; for 1 s sampling interval and 1 s send interval
— Number of server interfaces, max.10 of each "Server interfaces" / "Companion specification" type and 20 of the type "Reference namespace"
— Number of nodes for user-defined server interfaces, max.50 000
Alarms and ConditionsYes
— Number of program alarms400
— Number of alarms for system diagnostics200
Further protocols
MODBUSYes; MODBUS TCP
Isochronous mode
EquidistanceYes
Jitter, max.1 µs
S7 message functions
Number of login stations for message functions, max.64
number of subscriptions, max.750
number of tags/attributes for subscriptions, max.50 000
Program alarmsYes
Number of configurable program messages, max.10 000; Program messages are generated by the "Program_Alarm" block, ProDiag or GRAPH
Number of loadable program messages in RUN, max.10 000
Number of program alarms4 000
Number of alarms for system diagnostics1 000
Number of alarms for motion technology objects480
Test commissioning functions
Joint commission (Team Engineering)Yes; Parallel online access possible for up to 10 engineering systems
Status blockYes; Up to 16 simultaneously (in total across all ES clients)
Single stepNo
Number of breakpoints20
ProfilingNo
Status/control
Status/control variableYes; without fail-safe
Variablesinputs/outputs, bit memories, DBs, peripheral I/Os (without fail-safe), times, counters
— of which status variables, max.200; per job
— of which control variables, max.200; per job
Forcing
ForcingYes; without fail-safe
Forcing, variablesperipheral inputs/outputs (without fail-safe)
Number of variables, max.200
Diagnostic buffer
presentYes
Number of entries, max.3 200
— of which powerfail-proof1 000
Traces
Number of configurable Traces8
Memory size per trace, max.512 kbyte
Diagnostics indication LED
RUN/STOP LEDYes
ERROR LEDYes
MAINT LEDYes
ACT LEDYes; For memory card access
RDY LEDYes
COM LEDYes
Connection display LINK TX/RXYes
Supported technology objects
Motion ControlYes; Note: The number of technology objects affects the cycle time of the PLC program; selection guide via the TIA Selection Tool
Number of available Motion Control resources for technology objects12 800
— per speed-controlled axis40
— per positioning axis80
— per synchronous axis160
— per external encoder80
— per output cam20
— per cam track160
— per probe40
Number of available Extended Motion Control resources for technology objects420
— per cam (1 000 points and 50 segments)2
— per cam (10 000 points and 50 segments)20
— for each set of kinematics30
— per Interpreter60
— Per leading axis proxy3
— kinematics with up to 4 interpolating axesYes; max. 3D + orientation
— kinematics with 5 or more interpolating axesYes; only with S7-1500T Motion Control KinPlus, as of TIA Portal V18 / FW V3.0 to V3.1
— user-defined kinematicsYes
— SIMATIC Safe KinematicsYes; optional, as of Safe Kinematics V17 / FW V2.9 to V3.1
— Number of positioning axes at motion control cycle of 4 ms (typical value)55
— Number of positioning axes at motion control cycle of 8 ms (typical value)110
PID_CompactYes; Universal PID controller with integrated optimization
PID_3StepYes; PID controller with integrated optimization for valves
PID-TempYes; PID controller with integrated optimization for temperature
High-speed counterYes
Integrated Functions
Number of counters8; Event/cycle duration measurement
Counting frequency, max.32 kHz
Counting functions
Continuous countingYes
Measuring range
— Cycle duration measurement, min.10 µs; 5 µs minimum pulse width
— Cycle duration measurement, max.178 s
Accuracy
— Cycle duration measurementSampling of the time period with 41.67 ns increments
Potential separation digital inputs
between the channelsYes; 12 DI (X122/X132), in 2 groups of 6 DI each
Potential separation digital outputs
between the channelsNo; 8 DI/DQ (X122/X132) and 8 DI/DQ (X142)
Degree and class of protection
IP degree of protectionIP20 control cabinet installation / open type
Standards, approvals, certificates
Siemens Eco Profile (SEP)Siemens EcoTech
CE markYes
UKCA markYes
cULusYes
RCM (formerly C-TICK)Yes
KC approvalYes
EAC (formerly Gost-R)Yes
Ecological footprint
environmental product declarationYes
Global warming potential
— global warming potential, (total) [CO2 eq]403 kg
— global warming potential, (during production) [CO2 eq]107 kg
— global warming potential, (during operation) [CO2 eq]306 kg
— global warming potential, (after end of life cycle) [CO2 eq]-10.7 kg
Highest safety class achievable in safety mode
Performance level according to ISO 13849-1PLd (PLe if exclusively F-CPU is used)
SIL acc. to IEC 61508SIL 2 (SIL 3 if exclusively F-CPU is used)
Probability of failure (for service life of 20 years and repair time of 100 hours)
— Low demand mode: PFDavg in accordance with SIL2< 14.00E-04
— Low demand mode: PFDavg in accordance with SIL3< 2.00E-05 PLd (if exclusively F-CPU is used)
— High demand/continuous mode: PFH in accordance with SIL2< 14.00E-09
— High demand/continuous mode: PFH in accordance with SIL3if exclusively F-CPU is used: < 1.00E-09 (at a site altitude of up to 3000 m); < 2.00E-09 (at a site altitude of more than 3000 m and up to 4000 m)
Security
PROFINET Security Class1
signed firmware updateYes
securely removing dataYes
Ambient temperature during operation
min.0 °C
max.55 °C
Ambient temperature during storage/transportation
min.-40 °C; Long-term storage: -25 °C
max.70 °C; Long-term storage: +55 °C
Altitude during operation relating to sea level
Installation altitude above sea level, max.4 000 m; as of an altitude of 2000 m, the maximum ambient air temperature is reduced by 7 °C per 1000 m; see SINAMICS documentation for SINAMICS S120 drive components
Ambient air temperature-barometric pressure-altitudePermissible air pressure: 620 hPa ... 1 060 hPa
Programming language
— LADYes; incl. failsafe
— FBDYes; incl. failsafe
— STLYes
— SCLYes
— CFCNo
— GRAPHYes
Know-how protection
User program protection/password protectionYes
Copy protectionYes
Block protectionYes
Access protection
protection of confidential configuration dataYes
Protection level: Write protectionYes
Protection level: Read/write protectionYes
Protection level: Write protection for FailsafeYes
Protection level: Complete protectionYes
User administrationYes
Cycle time monitoring
lower limitadjustable minimum cycle time
upper limitadjustable maximum cycle time
Dimensions
Width50 mm
Height300 mm
Depth226 mm; 270 mm with spacer (included in scope of supply)
Weights
Weight, approx.2 400 g
Other
Note:The SIMATIC Drive Controller deviates from the usual SIMATIC S7-1500 ambient conditions and specifications as well as the available approvals and certificates because of the drive design. For details, see the SIMATIC Drive Controller device and system manual. Operation is without fan.

Related Products

1FN3003-0PB02-0AA3
Siemens 1FN3003-0PB02-0AA3
View Details

Siemens

1FN3003-0PB02-0AA3

MFR #1FN3003-0PB02-0AA3

SKU #YLS7ACYY31VH29I

1FN3003-0PB03-0AA3
Siemens 1FN3003-0PB03-0AA3
View Details

Siemens

1FN3003-0PB03-0AA3

MFR #1FN3003-0PB03-0AA3

SKU #YLSPDCXX5LUPVBP

1FN3003-0PB04-0BA3
Siemens 1FN3003-0PB04-0BA3
View Details

Siemens

1FN3003-0PB04-0BA3

MFR #1FN3003-0PB04-0BA3

SKU #YLSTLFTLVCKOIMT

1FN3003-0PB05-0BA3
Siemens 1FN3003-0PB05-0BA3
View Details

Siemens

1FN3003-0PB05-0BA3

MFR #1FN3003-0PB05-0BA3

SKU #YLS6EWIJX1ZRGHO

1FN3050-0TB00-1..0
Siemens 1FN3050-0TB00-1..0
View Details

Siemens

1FN3050-0TB00-1..0

MFR #1FN3050-0TB00-1..0

SKU #YLS5YVWHSMU6WB7

1FN3050-2NE00-0EA3
Siemens 1FN3050-2NE00-0EA3
View Details

Siemens

1FN3050-2NE00-0EA3

MFR #1FN3050-2NE00-0EA3

SKU #YLSE7XSY2HLF5EC

1FN3050-2NE00-0FA3
Siemens 1FN3050-2NE00-0FA3
View Details

Siemens

1FN3050-2NE00-0FA3

MFR #1FN3050-2NE00-0FA3

SKU #YLSMSUG5AP3INVD

1FN3100-0TB00-1..0
Siemens 1FN3100-0TB00-1..0
View Details

Siemens

1FN3100-0TB00-1..0

MFR #1FN3100-0TB00-1..0

SKU #YLSTD7J4JZ8UCBX

1FN3002-0TK03-1AF0
View Details

Siemens

1FN3002-0TK03-1AF0

MFR #1FN3002-0TK03-1AF0

SKU #YLS7VTGYJAP381B

1FN3050-1ND00-0HA3
View Details

Siemens

1FN3050-1ND00-0HA3

MFR #1FN3050-1ND00-0HA3

SKU #YLSJTX7SVU4GFKR

Featured Products

AL30-03-8-A
SMC AL30-03-8-A
View Details

SMC

AL30-03-8-A

MFR #AL30-03-8-A

SKU #YLS6GDABZE4BN7A

CM2B40-75Z
SMC CM2B40-75Z
View Details

SMC

CM2B40-75Z

MFR #CM2B40-75Z

SKU #YLSOGLJ512KWTEJ

NCDGFN25-0100
SMC NCDGFN25-0100
View Details

SMC

NCDGFN25-0100

MFR #NCDGFN25-0100

SKU #YLST0TDV975HLIN

AW20-N02CG-6CZ-B
SMC AW20-N02CG-6CZ-B
View Details

SMC

AW20-N02CG-6CZ-B

MFR #AW20-N02CG-6CZ-B

SKU #YLSNOOF0IBCZ3J3

VQZ2121-5LO1-N3T
SMC VQZ2121-5LO1-N3T
View Details

SMC

VQZ2121-5LO1-N3T

MFR #VQZ2121-5LO1-N3T

SKU #YLSEL35MGGQ9FOL

MGPL25TN-200BZ-XC9
SMC MGPL25TN-200BZ-XC9
View Details

SMC

MGPL25TN-200BZ-XC9

MFR #MGPL25TN-200BZ-XC9

SKU #YLSPBI637NOCN0Y

NCMC150-0600-X103US
SMC NCMC150-0600-X103US
View Details

SMC

NCMC150-0600-X103US

MFR #NCMC150-0600-X103US

SKU #YLS468HQT0B65QG

VQC2101R-51
SMC VQC2101R-51
View Details

SMC

VQC2101R-51

MFR #VQC2101R-51

SKU #YLSSEY6NT0YLZ8G

VFSWDM3546T-5E
Baldor VFSWDM3546T-5E
View Details

Baldor

VFSWDM3546T-5E

MFR #VFSWDM3546T-5E

SKU #YLSRYYEFOOW6J5E

SY5420-5DZ-01
SMC SY5420-5DZ-01
View Details

SMC

SY5420-5DZ-01

MFR #SY5420-5DZ-01

SKU #YLSQW9MERWL033X

Related Searches

Siemens 6ES7615-7DF10-0AB0 priceSiemens 6ES7615-7DF10-0AB0 quotebuy Siemens 6ES7615-7DF10-0AB06ES7615-7DF10-0AB0 price6ES7615-7DF10-0AB0 stock availabilitySiemens spare partsSiemens 6ES7615-7DF10-0AB0 equivalentSiemens 6ES7615-7DF10-0AB0 specifications