Siemens 6ES7518-4JP00-0AB0

Photo may not represent actual item. Refer to name and product specs for all details.

Siemens 6ES7518-4JP00-0AB0

SIMATIC S7-1500H, CPU 1518HF-4 PN, central processing unit with 9 MB work memory for program and 60 MB for data, 1st interface: PROFINET RT with 2-port switch, 2nd interface: PROFINET, 3rd interface: PROFINET, 4th/5th interface: H-SYNC, SIMATIC Memory Card required

SiemensMFR # 6ES7518-4JP00-0AB0SKU # YLSIMFSI0FHIXN4
Product type designationCPU 1518HF-4PN
HW functional statusFS04
Firmware versionV3.1
FW update possibleYes
I&M dataYes; I&M0 to I&M3
Isochronous modeNo
Share

About This Product

SIMATIC S7-1500H, CPU 1518HF-4 PN, central processing unit with 9 MB work memory for program and 60 MB for data, 1st interface: PROFINET RT with 2-port switch, 2nd interface: PROFINET, 3rd interface: PROFINET, 4th/5th interface: H-SYNC, SIMATIC Memory Card required

Siemens 6ES7518-4JP00-0AB0

  • Genuine, certified Siemens product
  • Fast sourcing through a worldwide supply network
  • Product selection and compatibility support from our technical team
  • Equivalent and alternative product suggestions
  • Quotation and lead time tailored to your request

Specifications

General information
Product type designationCPU 1518HF-4PN
HW functional statusFS04
Firmware versionV3.1
FW update possibleYes
Product function
I&M dataYes; I&M0 to I&M3
Isochronous modeNo
SysLogYes
Engineering with
STEP 7 TIA Portal configurable/integrated from versionV19 (FW V3.1) / V17 (FW V2.9) or higher
Display
Screen diagonal [cm]6.1 cm
Control elements
Number of keys6
Mode selector switch1
Supply voltage
Rated value (DC)24 V
permissible range, lower limit (DC)19.2 V
permissible range, upper limit (DC)28.8 V
Reverse polarity protectionYes
Mains buffering
Mains/voltage failure stored energy time5 ms
Repeat rate, min.1/s
Input current
Current consumption (rated value)1.55 A
Current consumption, max.1.95 A
Inrush current, max.1.95 A; Rated value
I²t0.4 A²·s
Power
Infeed power to the backplane bus12 W
Power consumption from the backplane bus (balanced)30 W
Power loss
Power loss, typ.24 W
Storage
Number of slots for SIMATIC memory card1
SIMATIC memory card requiredYes
Work memory
integrated (for program)9 Mbyte
integrated (for data)60 Mbyte
Load memory
Plug-in (SIMATIC Memory Card), max.32 Gbyte
Backup
maintenance-freeYes
CPU processing times
for bit operations, typ.4 ns
for word operations, typ.6 ns
for fixed point arithmetic, typ.6 ns
for floating point arithmetic, typ.24 ns
CPU-blocks
Number of elements (total)20 000; Blocks (OB, FB, FC, DB) and UDTs
DB
Number range1 ... 60 999; subdivided into: number range that can be used by the user: 1 ... 59 999, and number range of DBs created via SFC 86: 60 000 ... 60 999
Size, max.16 Mbyte; For DBs with absolute addressing, the max. size is 64 KB
FB
Number range0 ... 65 535
Size, max.1 Mbyte
FC
Number range0 ... 65 535
Size, max.1 Mbyte
OB
Size, max.1 Mbyte
Number of free cycle OBs100
Number of time alarm OBs20
Number of delay alarm OBs20
Number of cyclic interrupt OBs20; with minimum OB 3x cycle of 1 ms
Number of process alarm OBs50
Number of DPV1 alarm OBs3
Number of startup OBs100
Number of asynchronous error OBs4
Number of synchronous error OBs2
Number of diagnostic alarm OBs1
Nesting depth
per priority class24; Up to 8 possible for F-blocks
S7 counter
Number2 048
Retentivity
— adjustableYes
IEC counter
NumberAny (only limited by the main memory)
Retentivity
— adjustableYes
S7 timer
Number2 048
Retentivity
— adjustableYes
IEC timer
NumberAny (only limited by the main memory)
Retentivity
— can be setYes
Data areas and their retentivity
Retentive data area (incl. timers, counters, flags), max.768 kbyte; In total; available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 700 KB
Flag
Size, max.16 kbyte
Number of clock memories8; 8 clock memory bit, grouped into one clock memory byte
Data blocks
Retentivity adjustableYes
Retentivity presetNo
Local data
per priority class, max.64 kbyte; max. 16 KB per block
Address area
Number of IO modules8 192; max. number of modules / submodules
I/O address area
Inputs32 kbyte; All inputs are in the process image
Outputs32 kbyte; All outputs are in the process image
per integrated IO subsystem
— Inputs (volume)16 kbyte
— Outputs (volume)16 kbyte
Subprocess images
Number of subprocess images, max.31
Hardware configuration
Number of distributed IO systems64; A distributed I/O system is characterized not only by the integration of distributed I/O via PROFINET, but also by the connection of I/O via IE/PB-Links.
Number of IO Controllers
Integrated1
Rack
Modules per rack, max.9; CPU + 2 PS + 6 CP
Clock
TypeHardware clock
Backup time6 wk; At 40 °C ambient temperature, typically
Deviation per day, max.10 s; Typ.: 2 s
Operating hours counter
Number16
Clock synchronization
supportedYes
on Ethernet via NTPYes
Interfaces
Number of PROFINET interfaces3
Interface types
RJ 45 (Ethernet)Yes; X1
Number of ports2
integrated switchYes
Protocols
IP protocolYes; IPv4
PROFINET IO ControllerYes
PROFINET IO deviceNo
SIMATIC communicationYes; Only Server
Open IE communicationYes; Optionally also encrypted
Web serverYes
Media redundancyYes
Services
— Isochronous modeNo
— IRTNo
— Dynamic Frame Packing (DFP)Yes
— PROFIenergyYes; per user program
— Prioritized startupNo
— Number of connectable IO Devices, max.256
— Updating timesThe minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data
— PROFINET Security Class1
Update time for RT
— for send cycle of 1 ms1 ms to 512 ms
Interface types
RJ 45 (Ethernet)Yes; X2
Number of ports1
integrated switchNo
Protocols
IP protocolYes; IPv4
PROFINET IO ControllerNo
PROFINET IO DeviceNo
SIMATIC communicationYes; Only Server
Open IE communicationYes; Optionally also encrypted
Web serverYes
Media redundancyNo
Interface types
RJ 45 (Ethernet)Yes; X3
Number of ports1
integrated switchNo
Protocols
IP protocolYes; IPv4
PROFINET IO ControllerNo
PROFINET IO deviceNo
SIMATIC communicationYes; Only Server
Open IE communicationYes; Optionally also encrypted
Web serverYes
4. Interface
Interface typePluggable synchronization submodule (FO)
Plug-in interface modulesSynchronization module 6ES7960-1CB00-0AA5, 6ES7960-1FB00-0AA5 or 6ES7960-1FE00-0AA5
5. Interface
Interface typePluggable synchronization submodule (FO)
Plug-in interface modulesSynchronization module 6ES7960-1CB00-0AA5, 6ES7960-1FB00-0AA5 or 6ES7960-1FE00-0AA5
RJ 45 (Ethernet)
100 MbpsYes
1000 MbpsYes; Only possible at the X3 interface of the CPU 1518
AutonegotiationYes
AutocrossingYes
Industrial Ethernet status LEDYes
Protocols
PROFIsafeYes; V2.4 / V2.6
Number of connections
Number of connections, max.384; via integrated interfaces of the CPU and connected CPs
Number of connections reserved for ES/HMI/web10
Number of connections via integrated interfaces320
Number of S7 routing paths64
Redundancy mode
PROFINET system redundancy (S2)Yes
PROFINET system redundancy (R1)Yes
Media redundancy
— Media redundancyonly via 1st interface (X1)
— MRPYes; MRP Automanager according to IEC 62439-2 Edition 2.0
— MRP interconnection, supportedYes; as MRP ring node according to IEC 62439-2 Edition 3.0
— MRPDNo
— Switchover time on line break, typ.200 ms; PROFINET MRP
— Number of stations in the ring, max.50
SIMATIC communication
PG/OP communicationYes; encryption with TLS V1.3 pre-selected
S7 routingYes
S7 communication, as serverYes
S7 communication, as clientNo
Open IE communication
TCP/IPYes
— Data length, max.64 kbyte
— several passive connections per port, supportedYes
ISO-on-TCP (RFC1006)Yes
— Data length, max.64 kbyte
UDPYes
— Data length, max.2 kbyte; 1 472 bytes for UDP broadcast
— UDP multicastYes; 128 multicast circuits (of which max. 5 via X1)
DHCPNo
DNSYes
SNMPYes
DCPYes
LLDPYes
EncryptionYes; Optional
Web server
HTTPNo
HTTPSYes; only via Web API
web APIYes
— Number of sessions, max.200
— number of simultaneous HTTP calls, max.4
— HTTP request body, max.131 072 byte
OPC UA
Runtime license requiredYes; "Large" license required per CPU
OPC UA ClientNo
OPC UA ServerYes; Data access (read, write, subscribe), method call, custom address space
— Application authenticationYes
— Security policiesavailable security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256, Aes128Sha256RsaOaep, Aes256Sha256RsaPss
— User authentication"anonymous" or by user name & password
— GDS support (certificate management)No
— Number of sessions, max.32
— Number of subscriptions per session, max.25
— Sampling interval, min.25 ms
— Publishing interval, min.25 ms
— Number of server methods, max.100
— Number of inputs/outputs per server method, max.20
— Number of monitored items, recommended max.12 000; for 1 s sampling interval and 1 s send interval
— Number of server interfaces, max.10 of each "Server interfaces" / "Companion specification" type and 20 of the type "Reference namespace"
— Number of nodes for user-defined server interfaces, max.50 000
Alarms and ConditionsNo
Further protocols
MODBUSYes; MODBUS TCP
S7 message functions
Number of login stations for message functions, max.64
number of subscriptions, max.750
number of tags/attributes for subscriptions, max.50 000
Program alarmsYes
Number of configurable program messages, max.10 000; Program messages are generated by the "Program_Alarm" block, ProDiag or GRAPH
Number of loadable program messages in RUN, max.10 000
Number of program alarms4 000
Number of alarms for system diagnostics1 000
Test commissioning functions
Joint commission (Team Engineering)No
Status blockYes; Up to 16 simultaneously
Single stepNo
Number of breakpoints20; Breakpoints are only supported in RUN-Solo status
Status/control
Status/control variableYes; without fail-safe
Variablesinputs/outputs, bit memories, DBs, peripheral I/Os (without fail-safe), times, counters
— of which status variables, max.200; per job
— of which control variables, max.200; per job
Forcing
ForcingYes; without fail-safe
Forcing, variablesperipheral inputs/outputs (without fail-safe)
Number of variables, max.200
Diagnostic buffer
presentYes
Number of entries, max.3 200
— of which powerfail-proof1 000
Traces
Number of configurable Traces8
Memory size per trace, max.512 kbyte
Diagnostics indication LED
RUN/STOP LEDYes
ERROR LEDYes
MAINT LEDYes
Connection display LINK TX/RXYes
Supported technology objects
Motion ControlNo
PID_CompactYes; Universal PID controller with integrated optimization
PID_3StepYes; PID controller with integrated optimization for valves
PID-TempYes; PID controller with integrated optimization for temperature
Counting and measuringYes
Ecological footprint
environmental product declarationYes
Global warming potential
— global warming potential, (total) [CO2 eq]570 kg
— global warming potential, (during production) [CO2 eq]96.9 kg
— global warming potential, (during operation) [CO2 eq]483 kg
— global warming potential, (after end of life cycle) [CO2 eq]-9.97 kg
Highest safety class achievable in safety mode
Performance level according to ISO 13849-1PLe
SIL acc. to IEC 61508SIL 3
Probability of failure (for service life of 20 years and repair time of 100 hours)
— Low demand mode: PFDavg in accordance with SIL3< 2.00E-05
— High demand/continuous mode: PFH in accordance with SIL3< 1.00E-09
Security
PROFINET Security Class1
Ambient temperature during operation
horizontal installation, min.0 °C
horizontal installation, max.60 °C; Display: 50 °C, at an operating temperature of typically 50 °C, the display is switched off
vertical installation, min.0 °C
vertical installation, max.40 °C; Display: 40 °C, at an operating temperature of typically 40 °C, the display is switched off
Ambient temperature during storage/transportation
min.-40 °C
max.70 °C
Altitude during operation relating to sea level
Installation altitude above sea level, max.5 000 m; Restrictions for installation altitudes > 2 000 m, see manual
Programming language
— LADYes; incl. failsafe
— FBDYes; incl. failsafe
— STLYes
— SCLYes
— CFCYes; either CFC or failsafe functionality
— GRAPHYes
Know-how protection
User program protection/password protectionYes
Copy protectionNo
Block protectionYes
Access protection
protection of confidential configuration dataYes
Password for displayYes
Protection level: Write protectionYes
Protection level: Read/write protectionYes
Protection level: Write protection for FailsafeYes
Protection level: Complete protectionYes
User administrationYes
Cycle time monitoring
lower limitadjustable minimum cycle time
upper limitadjustable maximum cycle time
Dimensions
Width210 mm
Height147 mm
Depth129 mm
Weights
Weight, approx.2 116 g

Accessories 13

Genuine accessories that can be used with the Siemens 6ES7518-4JP00-0AB0 motor and are supplied separately are listed below. Click a code to open the accessory page and see the other compatible motors.

Part noDescriptionCompatible motors
6ES7590-1AB60-0AA0Aksesuar · Mounting rail
6ES7590-1AC40-0AA0Aksesuar · Mounting rail
6ES7590-1AF30-0AA0Aksesuar · Mounting rail
6ES7590-1AJ30-0AA0Aksesuar · Mounting rail
6ES7590-1BC00-0AA0Aksesuar · Mounting rail
6ES7590-0BD00-0AA0Aksesuar · Rack
6ES7590-0BH00-0AA0Aksesuar · Rack
6ES7590-0BL00-0AA0Aksesuar · Rack
6ES7592-1BM00-0XA0Yedek parça · Connection plug
6ES7590-0AA00-0AA0Yedek parça · spare part
6ES7528-0AA00-0AA0Yedek parça · spare part
6ES7592-1AX00-0AA0Yedek parça · label
6ES7590-1AE80-0AA0Zorunlu ek ürün · Mounting rail

Related Products

1FN3003-0PB02-0AA3
Siemens 1FN3003-0PB02-0AA3
View Details

Siemens

1FN3003-0PB02-0AA3

MFR #1FN3003-0PB02-0AA3

SKU #YLS7ACYY31VH29I

1FN3003-0PB03-0AA3
Siemens 1FN3003-0PB03-0AA3
View Details

Siemens

1FN3003-0PB03-0AA3

MFR #1FN3003-0PB03-0AA3

SKU #YLSPDCXX5LUPVBP

1FN3003-0PB04-0BA3
Siemens 1FN3003-0PB04-0BA3
View Details

Siemens

1FN3003-0PB04-0BA3

MFR #1FN3003-0PB04-0BA3

SKU #YLSTLFTLVCKOIMT

1FN3003-0PB05-0BA3
Siemens 1FN3003-0PB05-0BA3
View Details

Siemens

1FN3003-0PB05-0BA3

MFR #1FN3003-0PB05-0BA3

SKU #YLS6EWIJX1ZRGHO

1FN3050-0TB00-1..0
Siemens 1FN3050-0TB00-1..0
View Details

Siemens

1FN3050-0TB00-1..0

MFR #1FN3050-0TB00-1..0

SKU #YLS5YVWHSMU6WB7

1FN3050-2NE00-0EA3
Siemens 1FN3050-2NE00-0EA3
View Details

Siemens

1FN3050-2NE00-0EA3

MFR #1FN3050-2NE00-0EA3

SKU #YLSE7XSY2HLF5EC

1FN3050-2NE00-0FA3
Siemens 1FN3050-2NE00-0FA3
View Details

Siemens

1FN3050-2NE00-0FA3

MFR #1FN3050-2NE00-0FA3

SKU #YLSMSUG5AP3INVD

1FN3100-0TB00-1..0
Siemens 1FN3100-0TB00-1..0
View Details

Siemens

1FN3100-0TB00-1..0

MFR #1FN3100-0TB00-1..0

SKU #YLSTD7J4JZ8UCBX

1FN3002-0TK03-1AF0
View Details

Siemens

1FN3002-0TK03-1AF0

MFR #1FN3002-0TK03-1AF0

SKU #YLS7VTGYJAP381B

1FN3050-1ND00-0HA3
View Details

Siemens

1FN3050-1ND00-0HA3

MFR #1FN3050-1ND00-0HA3

SKU #YLSJTX7SVU4GFKR

Featured Products

EH22512
Danfoss Aeroquip LLC EH22512
View Details

Danfoss Aeroquip LLC

EH22512

MFR #EH22512

SKU #YLSRZ91UGVO64DG

MDBB63-100Z
SMC MDBB63-100Z
View Details

SMC

MDBB63-100Z

MFR #MDBB63-100Z

SKU #YLSNBPQBGLI90UX

VQZ2121-5LO1-N3T
SMC VQZ2121-5LO1-N3T
View Details

SMC

VQZ2121-5LO1-N3T

MFR #VQZ2121-5LO1-N3T

SKU #YLSEL35MGGQ9FOL

AL30-03-8-A
SMC AL30-03-8-A
View Details

SMC

AL30-03-8-A

MFR #AL30-03-8-A

SKU #YLS6GDABZE4BN7A

MGPM25-100Z-XC4
SMC MGPM25-100Z-XC4
View Details

SMC

MGPM25-100Z-XC4

MFR #MGPM25-100Z-XC4

SKU #YLSH71U0VZZBO5I

VFSWDM3546T-5E
Baldor VFSWDM3546T-5E
View Details

Baldor

VFSWDM3546T-5E

MFR #VFSWDM3546T-5E

SKU #YLSRYYEFOOW6J5E

MY1M20-200AH
SMC MY1M20-200AH
View Details

SMC

MY1M20-200AH

MFR #MY1M20-200AH

SKU #YLSIZ8K8N4KBPBQ

CM2B40-75Z
SMC CM2B40-75Z
View Details

SMC

CM2B40-75Z

MFR #CM2B40-75Z

SKU #YLSOGLJ512KWTEJ

ZCUKQ25-50D
SMC ZCUKQ25-50D
View Details

SMC

ZCUKQ25-50D

MFR #ZCUKQ25-50D

SKU #YLSQ684QXTNN958

MTS32-150M
SMC MTS32-150M
View Details

SMC

MTS32-150M

MFR #MTS32-150M

SKU #YLSSJCSBTRLX2P7

Related Searches

Siemens 6ES7518-4JP00-0AB0 priceSiemens 6ES7518-4JP00-0AB0 quotebuy Siemens 6ES7518-4JP00-0AB06ES7518-4JP00-0AB0 price6ES7518-4JP00-0AB0 stock availabilitySiemens spare partsSiemens 6ES7518-4JP00-0AB0 equivalentSiemens 6ES7518-4JP00-0AB0 specifications