SIMATIC DP, CPU 1514SP-2 PN for ET 200SP, central processing unit with 600 KB work memory for program and 3.5 MB for data, 1st interface: PROFINET IRT with 2-port switch, 2nd interface: PROFINET RT, 6 ns bit performance, including server module (6ES7193-6PA00-0AA0); SIMATIC Memory Card required, BusAdapter required for 1st interface

SiemensMFR # 6ES7514-2DN03-0AB0SKU # YLSICNI0RZJPAAH
Product type designationCPU 1514SP-2 PN
HW functional statusFS04
Firmware versionV4.0
FW update possibleYes
I&M dataYes; I&M0 to I&M3
SysLogYes
Share

About This Product

SIMATIC DP, CPU 1514SP-2 PN for ET 200SP, central processing unit with 600 KB work memory for program and 3.5 MB for data, 1st interface: PROFINET IRT with 2-port switch, 2nd interface: PROFINET RT, 6 ns bit performance, including server module (6ES7193-6PA00-0AA0); SIMATIC Memory Card required, BusAdapter required for 1st interface

Siemens 6ES7514-2DN03-0AB0

  • Genuine, certified Siemens product
  • Fast sourcing through a worldwide supply network
  • Product selection and compatibility support from our technical team
  • Equivalent and alternative product suggestions
  • Quotation and lead time tailored to your request

Specifications

General information
Product type designationCPU 1514SP-2 PN
HW functional statusFS04
Firmware versionV4.0
FW update possibleYes
Product function
I&M dataYes; I&M0 to I&M3
Module swapping during operation (hot swapping)Yes; Multi-hot swapping
Isochronous modeYes; only with PROFINET; with minimum OB 6x cycle of 375 µs
SysLogYes
Engineering with
STEP 7 TIA Portal configurable/integrated from versionV20 (FW V4.0) / V18 (FW V3.0) or higher
Configuration control
via datasetYes
Control elements
Mode selector switch1
Supply voltage
Rated value (DC)24 V
permissible range, lower limit (DC)19.2 V
permissible range, upper limit (DC)28.8 V
Reverse polarity protectionYes
Mains buffering
Mains/voltage failure stored energy time10 ms
Input current
Current consumption (rated value)0.48 A
Current consumption, max.0.7 A
Inrush current, max.1.34 A; Rated value
I²t0.3 A²·s
Power
Infeed power to the backplane bus8.05 W
Power loss
Power loss, typ.3.5 W
Storage
Number of slots for SIMATIC memory card1
SIMATIC memory card requiredYes
Work memory
integrated (for program)600 kbyte
integrated (for data)3.5 Mbyte
Load memory
Plug-in (SIMATIC Memory Card), max.32 Gbyte
Backup
maintenance-freeYes
CPU processing times
for bit operations, typ.6 ns
for word operations, typ.7 ns
for fixed point arithmetic, typ.9 ns
for floating point arithmetic, typ.37 ns
CPU-blocks
Number of elements (total)8 000; Blocks (OB, FB, FC, DB) and UDTs
DB
Number range1 ... 60 999; subdivided into: number range that can be used by the user: 1 ... 59 999, and number range of DBs created via SFC 86: 60 000 ... 60 999
Size, max.3.5 Mbyte; For DBs with absolute addressing, the max. size is 64 KB
FB
Number range0 ... 65 535
Size, max.600 kbyte
FC
Number range0 ... 65 535
Size, max.600 kbyte
OB
Size, max.600 kbyte
Number of free cycle OBs100
Number of time alarm OBs20
Number of delay alarm OBs20
Number of cyclic interrupt OBs20; With minimum OB 3x cycle of 250 µs
Number of process alarm OBs50
Number of DPV1 alarm OBs3
Number of isochronous mode OBs1
Number of technology synchronous alarm OBs2
Number of startup OBs100
Number of asynchronous error OBs4
Number of synchronous error OBs2
Number of diagnostic alarm OBs1
Nesting depth
per priority class24
S7 counter
Number2 048
Retentivity
— adjustableYes
IEC counter
NumberAny (only limited by the main memory)
Retentivity
— adjustableYes
S7 timer
Number2 048
Retentivity
— adjustableYes
IEC timer
NumberAny (only limited by the main memory)
Retentivity
— can be setYes
Data areas and their retentivity
Retentive data area (incl. timers, counters, flags), max.512 kbyte; In total; available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 472 KB
Flag
Size, max.16 kbyte
Number of clock memories8; 8 clock memory bit, grouped into one clock memory byte
Data blocks
Retentivity adjustableYes
Retentivity presetNo
Local data
per priority class, max.64 kbyte; max. 16 KB per block
Address area
Number of IO modules8 192; max. number of modules / submodules
I/O address area
Inputs32 kbyte; All inputs are in the process image
Outputs32 kbyte; All outputs are in the process image
per integrated IO subsystem
— Inputs (volume)8 kbyte
— Outputs (volume)8 kbyte
per CM/CP
— Inputs (volume)8 kbyte
— Outputs (volume)8 kbyte
Subprocess images
Number of subprocess images, max.32
Address space per module
Address space per module, max.288 byte; For input and output data respectively
Address space per station
Address space per station, max.2 560 byte; for central inputs and outputs; depending on configuration; 2 048 bytes for ET 200SP modules + 512 bytes for ET 200AL modules
Hardware configuration
Number of distributed IO systems64; A distributed I/O system is characterized not only by the integration of distributed I/O via PROFINET or PROFIBUS communication modules, but also by the connection of I/O via AS-i master modules or links (e.g. IE/PB-Link)
Number of DP masters
Via CM1
Number of IO Controllers
Integrated2
via CM0
Rack
Modules per rack, max.82; CPU + 64 modules + server module (mounting width max. 1 m) + 16 ET 200AL modules
Quantity of operable ET 200SP modules, max.64
Quantity of operable ET 200AL modules, max.16
Number of lines, max.1
PtP CM
Number of PtP CMsthe number of connectable PtP CMs is only limited by the number of available slots
Clock
TypeHardware clock
Backup time6 wk; At 40 °C ambient temperature, typically
Deviation per day, max.10 s; Typ.: 2 s
Operating hours counter
Number16
Clock synchronization
supportedYes
to DP, masterYes; Via CM DP module
on DP, deviceYes; Via CM DP module
in AS, masterYes
in AS, deviceYes
on Ethernet via NTPYes
Interfaces
Number of PROFINET interfaces2
Number of PROFIBUS interfaces1; Via CM DP module
Optical interfaceYes; Via SIMATIC BusAdapter
Interface types
RJ 45 (Ethernet)Yes; X1 P1 and X1 P2 via BusAdapter BA 2x RJ45
Number of ports2; via BusAdapter
integrated switchYes
BusAdapter (PROFINET)Yes; compatible BusAdapters: BA 2x RJ45, BA 2x M12, BA 2x FC, BA 2x LC, BA LC/RJ45, BA LC/FC, BA 2x SCRJ, BA SCRJ/RJ45, BA SCRJ/FC
Protocols
IP protocolYes; IPv4
PROFINET IO ControllerYes
PROFINET IO deviceYes
SIMATIC communicationYes
Open IE communicationYes; Optionally also encrypted
Web serverYes
Media redundancyYes
Services
— Isochronous modeYes
— Direct data exchangeYes; Requirement: IRT and isochronous mode (MRPD optional)
— IRTYes
— Dynamic Frame Packing (DFP)Yes
— PROFIenergyYes; per user program
— Prioritized startupYes; Max. 32 PROFINET devices
— Number of connectable IO Devices, max.256; in total, up to 1024 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET
— Of which IO devices with IRT, max.64
— Number of connectable IO Devices for RT, max.256
— of which in line, max.256
— Number of IO Devices that can be simultaneously activated/deactivated, max.8; in total across all interfaces
— Number of IO Devices per tool, max.8
— Updating timesThe minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data
— PROFINET Security Class1
Update time for IRT
— for send cycle of 250 µs250 μs to 4 ms; Note: In the case of IRT with isochronous mode, the minimum update time of 375 µs of the isochronous OB is decisive
— for send cycle of 500 µs500 µs to 8 ms
— for send cycle of 1 ms1 ms to 16 ms
— for send cycle of 2 ms2 ms to 32 ms
— for send cycle of 4 ms4 ms to 64 ms
— With IRT and parameterization of "odd" send cyclesUpdate time = set "odd" send clock (any multiple of 125 µs: 375 µs, 625 µs ... 3 875 µs)
Update time for RT
— for send cycle of 250 µs250 µs to 128 ms
— for send cycle of 500 µs500 µs to 256 ms
— for send cycle of 1 ms1 ms to 512 ms
— for send cycle of 2 ms2 ms to 512 ms
— for send cycle of 4 ms4 ms to 512 ms
Services
— Isochronous modeNo
— IRTYes
— Dynamic Frame Packing (DFP)No
— PROFIenergyYes; per user program
— Prioritized startupYes
— Shared deviceYes
— Number of IO Controllers with shared device, max.4
— activation/deactivation of I-devicesYes; per user program
— Asset management recordYes; per user program
— PROFINET Security ClassSNMP Configuration and DCP Read Only
Interface types
RJ 45 (Ethernet)Yes; X2
Number of ports1
integrated switchNo
Protocols
IP protocolYes; IPv4
PROFINET IO ControllerYes
PROFINET IO DeviceYes
SIMATIC communicationYes
Open IE communicationYes; Optionally also encrypted
Web serverYes
Media redundancyNo
Services
— Isochronous modeNo
— Direct data exchangeNo
— IRTNo
— Dynamic Frame Packing (DFP)No
— PROFIenergyYes; per user program
— Prioritized startupNo
— Number of connectable IO Devices, max.32; in total, up to 1024 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET
— Number of connectable IO Devices for RT, max.32
— of which in line, max.32
— Number of IO Devices that can be simultaneously activated/deactivated, max.8; in total across all interfaces
— IO Devices changing during operation (partner ports), supportedYes
— Number of IO Devices per tool, max.8
— Updating timesThe minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data
— PROFINET Security Class1
Update time for RT
— for send cycle of 1 ms1 ms to 512 ms
Services
— Isochronous modeNo
— IRTNo
— Dynamic Frame Packing (DFP)No
— PROFIenergyYes; per user program
— Prioritized startupNo
— Shared deviceYes
— Number of IO Controllers with shared device, max.4
— activation/deactivation of I-devicesYes; per user program
— Asset management recordYes; per user program
— PROFINET Security ClassSNMP Configuration and DCP Read Only
Interface types
RS 485Yes; Via CM DP module
Number of ports1
Protocols
PROFIBUS DP masterYes
PROFIBUS DP deviceYes
SIMATIC communicationYes
PROFIBUS DP master
Number of connections, max.48; Of which 4 each reserved for ES and HMI
max. number of DP devices125; in total, up to 1024 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET
Services
— EquidistanceNo
— Isochronous modeNo
— activation/deactivation of DP devicesYes
RJ 45 (Ethernet)
100 MbpsYes
AutonegotiationYes
AutocrossingYes
Industrial Ethernet status LEDYes
RS 485
Transmission rate, max.12 Mbit/s
Protocols
PROFIsafeNo
Number of connections
Number of connections, max.192; via integrated interfaces of the CPU and connected CPs / CMs
Number of connections reserved for ES/HMI/web10
Number of connections via integrated interfaces128
Number of connections per CP/CM32
Number of S7 routing paths16
Redundancy mode
PROFINET system redundancy (S2)No
PROFINET system redundancy (R1)No
H-Sync forwardingYes
Media redundancy
— Media redundancyYes; only via BusAdapter
— MRPYes; MRP Automanager according to IEC 62439-2 Edition 2.0, MRP Manager; MRP Client
— MRP interconnection, supportedYes; as MRP ring node according to IEC 62439-2 Edition 3.0
— MRPDYes; Requirement: IRT
— Switchover time on line break, typ.200 ms; For MRP, bumpless for MRPD
— Number of stations in the ring, max.50
SIMATIC communication
PG/OP communicationYes; encryption with TLS V1.3 pre-selected
S7 routingYes
Data record routingYes
S7 communication, as serverYes
S7 communication, as clientYes
User data per job, max.See online help (S7 communication, user data size)
Open IE communication
TCP/IPYes
— Data length, max.64 kbyte
— several passive connections per port, supportedYes
ISO-on-TCP (RFC1006)Yes
— Data length, max.64 kbyte
UDPYes
— Data length, max.2 kbyte; 1 472 bytes for UDP broadcast
— UDP multicastYes; max. 118 multicast circuits
DHCPYes
DNSYes
SNMPYes
DCPYes
LLDPYes
EncryptionYes; Optional
Web server
HTTPYes; Standard and user pages
HTTPSYes; Standard and user pages
— Number of sessions, max.100
— number of simultaneous HTTP calls, max.4
— HTTP request body, max.131 072 byte
OPC UA
Runtime license requiredYes; "Medium" license required
OPC UA ClientYes; Data Access (registered Read/Write), Method Call
— Application authenticationYes
— Security policiesAvailable security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256
— User authentication"anonymous" or by user name & password
— Number of connections, max.10
— Number of nodes of the client interfaces, recommended max.2 000
— Number of elements for one call of OPC_UA_NodeGetHandleList/OPC_UA_ReadList/OPC_UA_WriteList, max.300
— Number of elements for one call of OPC_UA_NameSpaceGetIndexList, max.20
— Number of elements for one call of OPC_UA_MethodGetHandleList, max.100
— Number of simultaneous calls of the client instructions for session management, per connection, max.1
— Number of simultaneous calls of the client instructions for data access, per connection, max.5
— Number of registerable nodes, max.5 000
— Number of registerable method calls of OPC_UA_MethodCall, max.100
— Number of inputs/outputs when calling OPC_UA_MethodCall, max.20
OPC UA ServerYes; data access (read, write, subscribe), method call, alarms & condition (A&C), custom address space, role-based access control
— Application authenticationYes
— Security policiesavailable security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256, Aes128Sha256RsaOaep, Aes256Sha256RsaPss
— User authentication"anonymous" or by user name & password
— GDS support (certificate management)Yes
— Number of sessions, max.48
— Number of accessible variables, max.100 000
— Number of registerable nodes, max.20 000
— Number of subscriptions per session, max.50
— Sampling interval, min.100 ms
— Publishing interval, min.100 ms
— Number of server methods, max.50; max. 20 concurrently running jobs each for asynchronous instructions OPC_UA_ServerMethodPre and OPC_UA_ServerMethodPost
— Number of inputs/outputs per server method, max.20
— Number of monitored items, recommended max.4 000; for 1 s sampling interval and 1 s send interval
— Number of server interfaces, max.10 of each "Server interfaces" / "Companion specification" type and 20 of the type "Reference namespace"
— Number of nodes for user-defined server interfaces, max.30 000
Alarms and ConditionsYes
— Number of program alarms200
— Number of alarms for system diagnostics100
Further protocols
MODBUSYes; MODBUS TCP
S7 message functions
Number of login stations for message functions, max.64
number of subscriptions, max.500
number of tags/attributes for subscriptions, max.8 000
Program alarmsYes
Number of configurable program messages, max.10 000; Program messages are generated by the "Program_Alarm" block, ProDiag or GRAPH
Number of loadable program messages in RUN, max.10 000
Number of program alarms1 000
Number of alarms for system diagnostics200
Number of alarms for motion technology objects160
Test commissioning functions
Joint commission (Team Engineering)Yes; Parallel online access possible for up to 8 engineering systems
Status blockYes; Up to 8 simultaneously (in total across all ES clients)
Single stepYes
Number of breakpoints8
ProfilingYes
Status/control
Status/control variableYes
VariablesInputs/outputs, memory bits, DBs, distributed I/Os, timers, counters
— of which status variables, max.200; per job
— of which control variables, max.200; per job
Forcing
ForcingYes
Forcing, variablesPeripheral inputs/outputs
Number of variables, max.200
Diagnostic buffer
presentYes
Number of entries, max.3 200
— of which powerfail-proof500
Traces
Number of configurable Traces4
Memory size per trace, max.512 kbyte
Diagnostics indication LED
RUN/STOP LEDYes
ERROR LEDYes
MAINT LEDYes
Monitoring of the supply voltage (PWR-LED)Yes
Connection display LINK TX/RXYes
Supported technology objects
Motion ControlYes; Note: The number of technology objects affects the cycle time of the PLC program; selection guide via the TIA Selection Tool
Number of available Motion Control resources for technology objects2 400
— per speed-controlled axis40
— per positioning axis80
— per synchronous axis160
— per external encoder80
— per output cam20
— per cam track160
— per probe40
— Number of positioning axes at motion control cycle of 4 ms (typical value)11
— Number of positioning axes at motion control cycle of 8 ms (typical value)20
PID_CompactYes; Universal PID controller with integrated optimization
PID_3StepYes; PID controller with integrated optimization for valves
PID-TempYes; PID controller with integrated optimization for temperature
High-speed counterYes
Ecological footprint
environmental product declarationYes
Global warming potential
— global warming potential, (total) [CO2 eq]83.2 kg
— global warming potential, (during production) [CO2 eq]22.3 kg
— global warming potential, (during operation) [CO2 eq]61.8 kg
— global warming potential, (after end of life cycle) [CO2 eq]-0.949 kg
Security
PROFINET Security Class1
signed firmware updateYes
Secure BootYes
securely removing dataYes
Ambient temperature during operation
horizontal installation, min.-30 °C; No condensation
horizontal installation, max.60 °C
vertical installation, min.-30 °C; No condensation
vertical installation, max.50 °C
Altitude during operation relating to sea level
Installation altitude above sea level, max.5 000 m; Restrictions for installation altitudes > 2 000 m, see manual
Programming language
— LADYes
— FBDYes
— STLYes
— SCLYes
— CFCYes
— GRAPHYes
Know-how protection
User program protection/password protectionYes
Copy protectionYes
Block protectionYes
Access protection
protection of confidential configuration dataYes
Protection level: Write protectionYes
Protection level: Read/write protectionYes
Protection level: Write protection for FailsafeNo
Protection level: Complete protectionYes
User administrationYes; device-wide and centralized
Number of users100
Number of groups100
Number of roles50
Cycle time monitoring
lower limitadjustable minimum cycle time
upper limitadjustable maximum cycle time
Dimensions
Width100 mm
Height117 mm
Depth75 mm
Weights
Weight, approx.265 g

Related Products

1FN3003-0PB02-0AA3
Siemens 1FN3003-0PB02-0AA3
View Details

Siemens

1FN3003-0PB02-0AA3

MFR #1FN3003-0PB02-0AA3

SKU #YLS7ACYY31VH29I

1FN3003-0PB03-0AA3
Siemens 1FN3003-0PB03-0AA3
View Details

Siemens

1FN3003-0PB03-0AA3

MFR #1FN3003-0PB03-0AA3

SKU #YLSPDCXX5LUPVBP

1FN3003-0PB04-0BA3
Siemens 1FN3003-0PB04-0BA3
View Details

Siemens

1FN3003-0PB04-0BA3

MFR #1FN3003-0PB04-0BA3

SKU #YLSTLFTLVCKOIMT

1FN3003-0PB05-0BA3
Siemens 1FN3003-0PB05-0BA3
View Details

Siemens

1FN3003-0PB05-0BA3

MFR #1FN3003-0PB05-0BA3

SKU #YLS6EWIJX1ZRGHO

1FN3050-0TB00-1..0
Siemens 1FN3050-0TB00-1..0
View Details

Siemens

1FN3050-0TB00-1..0

MFR #1FN3050-0TB00-1..0

SKU #YLS5YVWHSMU6WB7

1FN3050-2NE00-0EA3
Siemens 1FN3050-2NE00-0EA3
View Details

Siemens

1FN3050-2NE00-0EA3

MFR #1FN3050-2NE00-0EA3

SKU #YLSE7XSY2HLF5EC

1FN3050-2NE00-0FA3
Siemens 1FN3050-2NE00-0FA3
View Details

Siemens

1FN3050-2NE00-0FA3

MFR #1FN3050-2NE00-0FA3

SKU #YLSMSUG5AP3INVD

1FN3100-0TB00-1..0
Siemens 1FN3100-0TB00-1..0
View Details

Siemens

1FN3100-0TB00-1..0

MFR #1FN3100-0TB00-1..0

SKU #YLSTD7J4JZ8UCBX

1FN3002-0TK03-1AF0
View Details

Siemens

1FN3002-0TK03-1AF0

MFR #1FN3002-0TK03-1AF0

SKU #YLS7VTGYJAP381B

1FN3050-1ND00-0HA3
View Details

Siemens

1FN3050-1ND00-0HA3

MFR #1FN3050-1ND00-0HA3

SKU #YLSJTX7SVU4GFKR

Featured Products

NCDMC150-0600-X155US
SMC NCDMC150-0600-X155US
View Details

SMC

NCDMC150-0600-X155US

MFR #NCDMC150-0600-X155US

SKU #YLS8ICKGSKYC93L

AR30-N02E-1Z-B
SMC AR30-N02E-1Z-B
View Details

SMC

AR30-N02E-1Z-B

MFR #AR30-N02E-1Z-B

SKU #YLSYFNHADE6GRKV

BM3615T W/ 2-1/4" LONG SHAFT
Baldor BM3615T W/  2-1/4" LONG SHAFT
View Details

Baldor

BM3615T W/ 2-1/4" LONG SHAFT

MFR #BM3615T W/ 2-1/4" LONG SHAFT

SKU #YLSUV0OKQIKNTRJ

SY5420-5DZ-01
SMC SY5420-5DZ-01
View Details

SMC

SY5420-5DZ-01

MFR #SY5420-5DZ-01

SKU #YLSQW9MERWL033X

CDJ2L16-125Z-B
SMC CDJ2L16-125Z-B
View Details

SMC

CDJ2L16-125Z-B

MFR #CDJ2L16-125Z-B

SKU #YLS5V0RW2VJJR1A

AW20-N02CG-6CZ-B
SMC AW20-N02CG-6CZ-B
View Details

SMC

AW20-N02CG-6CZ-B

MFR #AW20-N02CG-6CZ-B

SKU #YLSNOOF0IBCZ3J3

CM2B40-75Z
SMC CM2B40-75Z
View Details

SMC

CM2B40-75Z

MFR #CM2B40-75Z

SKU #YLSOGLJ512KWTEJ

MXQ25L-40B-M9NZ
SMC MXQ25L-40B-M9NZ
View Details

SMC

MXQ25L-40B-M9NZ

MFR #MXQ25L-40B-M9NZ

SKU #YLSD1VANMRI726Z

VQC2101R-51
SMC VQC2101R-51
View Details

SMC

VQC2101R-51

MFR #VQC2101R-51

SKU #YLSSEY6NT0YLZ8G

MY1M20-200AH
SMC MY1M20-200AH
View Details

SMC

MY1M20-200AH

MFR #MY1M20-200AH

SKU #YLSIZ8K8N4KBPBQ

Related Searches

Siemens 6ES7514-2DN03-0AB0 priceSiemens 6ES7514-2DN03-0AB0 quotebuy Siemens 6ES7514-2DN03-0AB06ES7514-2DN03-0AB0 price6ES7514-2DN03-0AB0 stock availabilitySiemens spare partsSiemens 6ES7514-2DN03-0AB0 equivalentSiemens 6ES7514-2DN03-0AB0 specifications