SIMATIC S7-1500 Compact CPU CPU 1512C-1 PN, central processing unit with working memory 250 KB for program and 1 MB for data, 32 digital inputs, 32 digital outputs, 5 analog inputs, 2 analog outputs, 6 high speed counters, 4 high speed outputs for PTO/PWM/frequency output 1. interface: PROFINET IRT with 2 port switch, 48 NS bit-performance, incl. front connector push-in, SIMATIC memory card necessary

SiemensMFR # 6ES7512-1CK01-0AB0SKU # CEY-937FC78031F4
Product type designationCPU 1512C-1 PN
HW functional statusFS03
Firmware versionV2.9
I&M dataYes; I&M0 to I&M3
via datasetYes
Screen diagonal [cm]3.45 cm
Share

About This Product

SIMATIC S7-1500 Compact CPU CPU 1512C-1 PN, central processing unit with working memory 250 KB for program and 1 MB for data, 32 digital inputs, 32 digital outputs, 5 analog inputs, 2 analog outputs, 6 high speed counters, 4 high speed outputs for PTO/PWM/frequency output 1. interface: PROFINET IRT with 2 port switch, 48 NS bit-performance, incl. front connector push-in, SIMATIC memory card necessary

Siemens 6ES7512-1CK01-0AB0

  • Genuine, certified Siemens product
  • Fast sourcing through a worldwide supply network
  • Product selection and compatibility support from our technical team
  • Equivalent and alternative product suggestions
  • Quotation and lead time tailored to your request

Specifications

General information
Product type designationCPU 1512C-1 PN
HW functional statusFS03
Firmware versionV2.9
Product function
I&M dataYes; I&M0 to I&M3
Isochronous modeYes; With minimum OB 6x cycle of 625 µs (distributed)
Engineering with
STEP 7 TIA Portal configurable/integrated from versionV17 (FW V2.9) / V15 (FW V2.5) or higher; with older TIA Portal versions configurable as 6ES7512-1CK00-0AB0
Configuration control
via datasetYes
Display
Screen diagonal [cm]3.45 cm
Control elements
Number of keys8
Mode buttons2
Supply voltage
Rated value (DC)24 V
permissible range, lower limit (DC)19.2 V; 20.4 V DC, for supplying the digital inputs/outputs
permissible range, upper limit (DC)28.8 V
Reverse polarity protectionYes
Mains buffering
Mains/voltage failure stored energy time5 ms; Refers to the power supply on the CPU section
Repeat rate, min.1/s
Input current
Current consumption (rated value)0.8 A; Without load; 18.8 A: CPU + load
Current consumption, max.1 A; Without load; 19 A: CPU + load
Inrush current, max.1.9 A; Rated value
I²t0.34 A²·s
Digital inputs
from load voltage L+ (without load), max.20 mA; per group
Digital outputs
from load voltage L+, max.30 mA; Per group, without load
Encoder supply
Number of outputs2; One common 24 V encoder supply per 16 digital inputs
24 V encoder supply
24 VYes; L+ (-0.8 V)
Short-circuit protectionYes
Output current, max.1 A
Power
Infeed power to the backplane bus10 W
Power consumption from the backplane bus (balanced)9 W
Power loss
Power loss, typ.15.2 W
Storage
Number of slots for SIMATIC memory card1
SIMATIC memory card requiredYes
Work memory
integrated (for program)250 kbyte
integrated (for data)1 Mbyte
Load memory
Plug-in (SIMATIC Memory Card), max.32 Gbyte
Backup
maintenance-freeYes
CPU processing times
for bit operations, typ.48 ns
for word operations, typ.58 ns
for fixed point arithmetic, typ.77 ns
for floating point arithmetic, typ.307 ns
CPU-blocks
Number of elements (total)4 000; Blocks (OB, FB, FC, DB) and UDTs
DB
Number range1 ... 60 999; subdivided into: number range that can be used by the user: 1 ... 59 999, and number range of DBs created via SFC 86: 60 000 ... 60 999
Size, max.1 Mbyte; For DBs with absolute addressing, the max. size is 64 KB
FB
Number range0 ... 65 535
Size, max.250 kbyte
FC
Number range0 ... 65 535
Size, max.250 kbyte
OB
Size, max.250 kbyte
Number of free cycle OBs100
Number of time alarm OBs20
Number of delay alarm OBs20
Number of cyclic interrupt OBs20; With minimum OB 3x cycle of 500 µs
Number of process alarm OBs50
Number of DPV1 alarm OBs3
Number of isochronous mode OBs1
Number of technology synchronous alarm OBs2
Number of startup OBs100
Number of asynchronous error OBs4
Number of synchronous error OBs2
Number of diagnostic alarm OBs1
Nesting depth
per priority class24
S7 counter
Number2 048
Retentivity
— adjustableYes
IEC counter
NumberAny (only limited by the main memory)
Retentivity
— adjustableYes
S7 timer
Number2 048
Retentivity
— adjustableYes
IEC timer
NumberAny (only limited by the main memory)
Retentivity
— can be setYes
Data areas and their retentivity
Retentive data area (incl. timers, counters, flags), max.128 kbyte; In total; available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 88 KB
Extended retentive data area (incl. timers, counters, flags), max.1 Mbyte; When using PS 6 0W 24/48/60 V DC HF
Flag
Size, max.16 kbyte
Number of clock memories8; 8 clock memory bit, grouped into one clock memory byte
Data blocks
Retentivity adjustableYes
Retentivity presetNo
Local data
per priority class, max.64 kbyte; max. 16 KB per block
Address area
Number of IO modules2 048; max. number of modules / submodules
I/O address area
Inputs32 kbyte; All inputs are in the process image
Outputs32 kbyte; All outputs are in the process image
per integrated IO subsystem
— Inputs (volume)8 kbyte
— Outputs (volume)8 kbyte
per CM/CP
— Inputs (volume)8 kbyte
— Outputs (volume)8 kbyte
Subprocess images
Number of subprocess images, max.32
Hardware configuration
Number of distributed IO systems32; A distributed I/O system is characterized not only by the integration of distributed I/O via PROFINET or PROFIBUS communication modules, but also by the connection of I/O via AS-i master modules or links (e.g. IE/PB-Link)
Number of DP masters
Via CM6; A maximum of 6 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total
Number of IO Controllers
Integrated1
via CM6; A maximum of 6 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total
Rack
Modules per rack, max.32; CPU + 31 modules
Number of lines, max.1
PtP CM
Number of PtP CMsthe number of connectable PtP CMs is only limited by the number of available slots
Clock
TypeHardware clock
Backup time6 wk; At 40 °C ambient temperature, typically
Deviation per day, max.10 s; Typ.: 2 s
Operating hours counter
Number16
Clock synchronization
supportedYes
in AS, masterYes
in AS, deviceYes
on Ethernet via NTPYes
Digital inputs
integrated channels (DI)32
Digital inputs, parameterizableYes
Sourcing/sinking inputP-reading
Input characteristic curve in accordance with IEC 61131, type 3Yes
Digital input functions, parameterizable
Gate start/stopYes
CaptureYes
SynchronizationYes
Input voltage
Type of input voltageDC
Rated value (DC)24 V
for signal "0"-3 to +5V
for signal "1"+11 to +30V
Input current
for signal "1", typ.2.5 mA
for standard inputs
— parameterizableYes; none / 0.05 / 0.1 / 0.4 / 1.6 / 3.2 / 12.8 / 20 ms
— at "0" to "1", min.4 µs; for parameterization "none"
— at "0" to "1", max.20 ms
— at "1" to "0", min.4 µs; for parameterization "none"
— at "1" to "0", max.20 ms
for interrupt inputs
— ParameterizableYes; Same as for standard inputs
for technological functions
— ParameterizableYes; Same as for standard inputs
Cable length
shielded, max.1 000 m; 600 m for technological functions; depending on input frequency, encoder and cable quality; max. 50 m at 100 kHz
unshielded, max.600 m; for technological functions: No
Digital outputs
Type of digital outputTransistor
integrated channels (DO)32
Current-sourcingYes; Push-pull output
Short-circuit protectionYes; electronic/thermal
Response threshold, typ.1.6 A with standard output, 0.5 A with high-speed output; see manual for details
Limitation of inductive shutdown voltage toConnector X11: -0.8 V; connector X12: L+ (-53 V)
Controlling a digital inputYes
Accuracy of pulse durationUp to ±100 ppm ±2 μs at high-speed output; see manual for details
minimum pulse duration2 µs; With High Speed output
Digital output functions, parameterizable
Switching tripped by comparison valuesYes; As output signal of a high-speed counter
PWM outputYes
— Number, max.4
— Cycle duration, parameterizableYes
— ON period, min.0 %
— ON period, max.100 %
— Resolution of the duty cycle0.0036 %; For S7 analog format, min. 40 ns
Frequency outputYes
Switching capacity of the outputs
with resistive load, max.0.5 A; 0.1 A with high-speed output, i.e. when using a high-speed output; see manual for details
on lamp load, max.5 W; 1 W with high-speed output, i.e. when using a high-speed output; see manual for details
Load resistance range
lower limit48 Ω; 240 ohms with high-speed output, i.e. when using a high-speed output; see manual for details
upper limit12 kΩ
Output voltage
Type of output voltageDC
for signal "0", max.1 V; With high-speed output, i.e. when using a high-speed output; see manual for details
for signal "1", min.23.2 V; L+ (-0.8 V)
Output current
for signal "1" rated value0.5 A; 0.1 A with high-speed output, i.e. when using a high-speed output, observe derating; see manual for details
for signal "1" permissible range, min.2 mA
for signal "1" permissible range, max.0.6 A; 0.12 A with high-speed output, i.e. when using a high-speed output, observe derating; see manual for details
for signal "0" residual current, max.0.5 mA
Output delay with resistive load
"0" to "1", max.200 µs
"1" to "0", max.500 µs; Load-dependent
for technological functions
— "0" to "1", max.5 µs; Depending on the output used, see additional description in manual
— "1" to "0", max.5 µs; Depending on the output used, see additional description in manual
Parallel switching of two outputs
for logic linksYes; for technological functions: No
for upratingNo
for redundant control of a loadYes; for technological functions: No
Switching frequency
with resistive load, max.100 kHz; For high-speed output, 100 Hz for standard output
with inductive load, max.0.5 Hz; Acc. to IEC 60947-5-1, DC-13; observe derating curve
on lamp load, max.10 Hz
Total current of the outputs
Current per channel, max.0.5 A; see additional description in the manual
Current per group, max.8 A; see additional description in the manual
Current per power supply, max.4 A; 2 power supplies for each group, current per power supply max. 4 A, see additional description in manual
for technological functions
— Current per channel, max.0.5 A; see additional description in the manual
Relay outputs
Number of relay outputs0
Cable length
shielded, max.1 000 m; 600 m for technological functions; depending on output frequency, load, and cable quality; max. 50 m at 100 kHz
unshielded, max.600 m; for technological functions: No
Analog inputs
Number of analog inputs5; 4x for U/I, 1x for R/RTD
For current measurement4; max.
For voltage measurement4; max.
For resistance/resistance thermometer measurement1
permissible input voltage for voltage input (destruction limit), max.28.8 V
permissible input current for current input (destruction limit), max.40 mA
Cycle time (all channels), min.1 ms; Dependent on the parameterized interference frequency suppression; for details, see conversion procedure in manual
Technical unit for temperature measurement adjustableYes; °C/°F/K
Input ranges (rated values), voltages
0 to +10 VYes; Physical measuring range: ± 10 V
— Input resistance (0 to 10 V)100 kΩ
1 V to 5 VYes; Physical measuring range: ± 10 V
— Input resistance (1 V to 5 V)100 kΩ
-10 V to +10 VYes
— Input resistance (-10 V to +10 V)100 kΩ
-5 V to +5 VYes; Physical measuring range: ± 10 V
— Input resistance (-5 V to +5 V)100 kΩ
Input ranges (rated values), currents
0 to 20 mAYes; Physical measuring range: ± 20 mA
— Input resistance (0 to 20 mA)50 Ω; Plus approx. 55 ohm for overvoltage protection by PTC
-20 mA to +20 mAYes
— Input resistance (-20 mA to +20 mA)50 Ω; Plus approx. 55 ohm for overvoltage protection by PTC
4 mA to 20 mAYes; Physical measuring range: ± 20 mA
— Input resistance (4 mA to 20 mA)50 Ω; Plus approx. 55 ohm for overvoltage protection by PTC
Input ranges (rated values), resistance thermometer
Ni 100Yes; Standard/climate
— Input resistance (Ni 100)10 MΩ
Pt 100Yes; Standard/climate
— Input resistance (Pt 100)10 MΩ
Input ranges (rated values), resistors
0 to 150 ohmsYes; Physical measuring range: 0 ... 600 ohms
— Input resistance (0 to 150 ohms)10 MΩ
0 to 300 ohmsYes; Physical measuring range: 0 ... 600 ohms
— Input resistance (0 to 300 ohms)10 MΩ
0 to 600 ohmsYes
— Input resistance (0 to 600 ohms)10 MΩ
Cable length
shielded, max.800 m; for U/I, 200 m for R/RTD
Analog outputs
integrated channels (AO)2
Voltage output, short-circuit protectionYes
Cycle time (all channels), min.1 ms; Dependent on the parameterized interference frequency suppression; for details, see conversion procedure in manual
Output ranges, voltage
0 to 10 VYes
1 V to 5 VYes
-10 V to +10 VYes
Output ranges, current
0 to 20 mAYes
-20 mA to +20 mAYes
4 mA to 20 mAYes
Load impedance (in rated range of output)
with voltage outputs, min.1 kΩ
with voltage outputs, capacitive load, max.100 nF
with current outputs, max.500 Ω
with current outputs, inductive load, max.1 mH
Cable length
shielded, max.200 m
Integration and conversion time/resolution per channel
Resolution with overrange (bit including sign), max.16 bit
Integration time, parameterizableYes; 2.5 / 16.67 / 20 / 100 ms, acts on all channels
Interference voltage suppression for interference frequency f1 in Hz400 / 60 / 50 / 10
Smoothing of measured values
parameterizableYes
Step: NoneYes
Step: lowYes
Step: MediumYes
Step: HighYes
Integration and conversion time/resolution per channel
Resolution with overrange (bit including sign), max.16 bit
Settling time
for resistive load1.5 ms
for capacitive load2.5 ms
for inductive load2.5 ms
Connection of signal encoders
for voltage measurementYes
for current measurement as 4-wire transducerYes
for resistance measurement with two-wire connectionYes
for resistance measurement with three-wire connectionYes
for resistance measurement with four-wire connectionYes
Connectable encoders
2-wire sensorYes
— permissible quiescent current (2-wire sensor), max.1.5 mA
Encoder signals, incremental encoder (asymmetrical)
Input voltage24 V
Input frequency, max.100 kHz
Counting frequency, max.400 kHz; with quadruple evaluation
Signal filter, parameterizableYes
Incremental encoder with A/B tracks, 90° phase offsetYes
Incremental encoder with A/B tracks, 90° phase offset and zero trackYes
pulse encoderYes
pulse encoder with directionYes
pulse encoder with one impulse signal per count directionYes
Errors/accuracies
Linearity error (relative to input range), (+/-)0.1 %
Temperature error (relative to input range), (+/-)0.005 %/K
Crosstalk between the inputs, max.-60 dB
Repeat accuracy in steady state at 25 °C (relative to input range), (+/-)0.05 %
Output ripple (relative to output range, bandwidth 0 to 50 kHz), (+/-)0.02 %
Linearity error (relative to output range), (+/-)0.15 %
Temperature error (relative to output range), (+/-)0.005 %/K
Crosstalk between the outputs, max.-80 dB
Repeat accuracy in steady state at 25 °C (relative to output range), (+/-)0.05 %
Operational error limit in overall temperature range
Voltage, relative to input range, (+/-)0.3 %
Current, relative to input range, (+/-)0.3 %
Resistance, relative to input range, (+/-)0.3 %
Resistance thermometer, relative to input range, (+/-)Pt100 Standard: ±2 K, Pt100 Climate: ±1 K, Ni100 Standard: ±1.2 K, Ni100 Climate: ±1 K
Voltage, relative to output range, (+/-)0.3 %
Current, relative to output range, (+/-)0.3 %
Basic error limit (operational limit at 25 °C)
Voltage, relative to input range, (+/-)0.2 %
Current, relative to input range, (+/-)0.2 %
Resistance, relative to input range, (+/-)0.2 %
Resistance thermometer, relative to input range, (+/-)Pt100 Standard: ±1 K, Pt100 Climate: ±0.5 K, Ni100 Standard: ±0.6 K, Ni100 Climate: ±0.5 K
Voltage, relative to output range, (+/-)0.2 %
Current, relative to output range, (+/-)0.2 %
Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency
Series mode interference (peak value of interference < rated value of input range), min.30 dB
Common mode voltage, max.10 V
Common mode interference, min.60 dB; at 400 Hz: 50 dB
Interfaces
Number of PROFINET interfaces1
Interface types
RJ 45 (Ethernet)Yes; X1
Number of ports2
integrated switchYes
Protocols
IP protocolYes; IPv4
PROFINET IO ControllerYes
PROFINET IO deviceYes
SIMATIC communicationYes
Open IE communicationYes; Optionally also encrypted
Web serverYes
Media redundancyYes
Services
— PG/OP communicationYes
— Isochronous modeYes
— Direct data exchangeYes; Requirement: IRT and isochronous mode (MRPD optional)
— IRTYes
— Dynamic Frame Packing (DFP)Yes
— PROFIenergyYes; per user program
— Prioritized startupYes; Max. 32 PROFINET devices
— Number of connectable IO Devices, max.128; In total, up to 256 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET
— Of which IO devices with IRT, max.64
— Number of connectable IO Devices for RT, max.128
— of which in line, max.128
— Number of IO Devices that can be simultaneously activated/deactivated, max.8; in total across all interfaces
— Number of IO Devices per tool, max.8
— Updating timesThe minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data
Update time for IRT
— for send cycle of 250 µs250 μs to 4 ms; Note: In the case of IRT with isochronous mode, the minimum update time of 625 µs of the isochronous OB is decisive
— for send cycle of 500 µs500 μs to 8 ms; Note: In the case of IRT with isochronous mode, the minimum update time of 625 µs of the isochronous OB is decisive
— for send cycle of 1 ms1 ms to 16 ms
— for send cycle of 2 ms2 ms to 32 ms
— for send cycle of 4 ms4 ms to 64 ms
— With IRT and parameterization of "odd" send cyclesUpdate time = set "odd" send clock (any multiple of 125 µs: 375 µs, 625 µs ... 3 875 µs)
Update time for RT
— for send cycle of 250 µs250 µs to 128 ms
— for send cycle of 500 µs500 µs to 256 ms
— for send cycle of 1 ms1 ms to 512 ms
— for send cycle of 2 ms2 ms to 512 ms
— for send cycle of 4 ms4 ms to 512 ms
Services
— PG/OP communicationYes
— Isochronous modeNo
— IRTYes
— Dynamic Frame Packing (DFP)No
— PROFIenergyYes; per user program
— Prioritized startupYes
— Shared deviceYes
— Number of IO Controllers with shared device, max.4
— activation/deactivation of I-devicesYes; per user program
— Asset management recordYes; per user program
RJ 45 (Ethernet)
100 MbpsYes
AutonegotiationYes
AutocrossingYes
Industrial Ethernet status LEDYes
Number of connections
Number of connections, max.128; via integrated interfaces of the CPU and connected CPs / CMs
Number of connections reserved for ES/HMI/web10
Number of connections via integrated interfaces88
Number of S7 routing paths16
Redundancy mode
PROFINET system redundancy (S2)No
PROFINET system redundancy (R1)No
H-Sync forwardingYes
Media redundancy
— Media redundancyonly via 1st interface (X1)
— MRPYes; MRP Automanager according to IEC 62439-2 Edition 2.0, MRP Manager; MRP Client
— MRP interconnection, supportedYes; as MRP ring node according to IEC 62439-2 Edition 3.0
— MRPDYes; Requirement: IRT
— Switchover time on line break, typ.200 ms; For MRP, bumpless for MRPD
— Number of stations in the ring, max.50
SIMATIC communication
PG/OP communicationYes; encryption with TLS V1.3 pre-selected
S7 routingYes
S7 communication, as serverYes
S7 communication, as clientYes
User data per job, max.See online help (S7 communication, user data size)
Open IE communication
TCP/IPYes
— Data length, max.64 kbyte
— several passive connections per port, supportedYes
ISO-on-TCP (RFC1006)Yes
— Data length, max.64 kbyte
UDPYes
— Data length, max.2 kbyte; 1 472 bytes for UDP broadcast
— UDP multicastYes; Max. 5 multicast circuits
DHCPYes
DNSYes
SNMPYes
DCPYes
LLDPYes
EncryptionYes; Optional
Web server
HTTPYes; Standard and user pages
HTTPSYes; Standard and user pages
OPC UA
Runtime license requiredYes; "Small" license required
OPC UA ClientYes
— Application authenticationYes
— Security policiesAvailable security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256
— User authentication"anonymous" or by user name & password
— Number of connections, max.4
— Number of nodes of the client interfaces, recommended max.1 000
— Number of elements for one call of OPC_UA_NodeGetHandleList/OPC_UA_ReadList/OPC_UA_WriteList, max.300
— Number of elements for one call of OPC_UA_NameSpaceGetIndexList, max.20
— Number of elements for one call of OPC_UA_MethodGetHandleList, max.100
— Number of simultaneous calls of the client instructions for session management, per connection, max.1
— Number of simultaneous calls of the client instructions for data access, per connection, max.5
— Number of registerable nodes, max.5 000
— Number of registerable method calls of OPC_UA_MethodCall, max.100
— Number of inputs/outputs when calling OPC_UA_MethodCall, max.20
OPC UA ServerYes; Data access (read, write, subscribe), method call, custom address space
— Application authenticationYes
— Security policiesAvailable security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256
— User authentication"anonymous" or by user name & password
— GDS support (certificate management)Yes
— Number of sessions, max.32
— Number of accessible variables, max.50 000
— Number of registerable nodes, max.10 000
— Number of subscriptions per session, max.20
— Sampling interval, min.100 ms
— Publishing interval, min.500 ms
— Number of server methods, max.20
— Number of inputs/outputs per server method, max.20
— Number of monitored items, recommended max.1 000; for 1 s sampling interval and 1 s send interval
— Number of server interfaces, max.10 of each "Server interfaces" / "Companion specification" type and 20 of the type "Reference namespace"
— Number of nodes for user-defined server interfaces, max.1 000
Alarms and ConditionsYes
— Number of program alarms100
— Number of alarms for system diagnostics50
Further protocols
MODBUSYes; MODBUS TCP
Isochronous mode
EquidistanceYes
S7 message functions
Number of login stations for message functions, max.32
Program alarmsYes
Number of configurable program messages, max.5 000; Program messages are generated by the "Program_Alarm" block, ProDiag or GRAPH
Number of loadable program messages in RUN, max.2 500
Number of program alarms600
Number of alarms for system diagnostics100
Number of alarms for motion technology objects80
Test commissioning functions
Joint commission (Team Engineering)Yes; Parallel online access possible for up to 5 engineering systems
Status blockYes; Up to 8 simultaneously (in total across all ES clients)
Single stepNo
Number of breakpoints8
Status/control
Status/control variableYes
VariablesInputs/outputs, memory bits, DBs, distributed I/Os, timers, counters
— of which status variables, max.200; per job
— of which control variables, max.200; per job
Forcing
ForcingYes
Forcing, variablesPeripheral inputs/outputs
Number of variables, max.200
Diagnostic buffer
presentYes
Number of entries, max.1 000
— of which powerfail-proof500
Traces
Number of configurable Traces4; Up to 512 KB of data per trace are possible
Alarms
Diagnostic alarmYes
Hardware interruptYes
Diagnoses
Monitoring the supply voltageYes
Wire breakYes; for analog inputs/outputs, see description in manual
Short-circuitYes; for analog outputs, see description in manual
A/B transition error at incremental encoderYes
Diagnostics indication LED
RUN/STOP LEDYes
ERROR LEDYes
MAINT LEDYes
STOP ACTIVE LEDYes
Monitoring of the supply voltage (PWR-LED)Yes
Channel status displayYes
for channel diagnosticsYes; For analog inputs/outputs
Connection display LINK TX/RXYes
Supported technology objects
Motion ControlYes; Note: The number of technology objects affects the cycle time of the PLC program; selection guide via the TIA Selection Tool
Number of available Motion Control resources for technology objects800
— per speed-controlled axis40
— per positioning axis80
— per synchronous axis160
— per external encoder80
— per output cam20
— per cam track160
— per probe40
— Number of positioning axes at motion control cycle of 4 ms (typical value)5
— Number of positioning axes at motion control cycle of 8 ms (typical value)10
PID_CompactYes; Universal PID controller with integrated optimization
PID_3StepYes; PID controller with integrated optimization for valves
PID-TempYes; PID controller with integrated optimization for temperature
High-speed counterYes
Integrated Functions
Number of counters6
Counting frequency, max.400 kHz; with quadruple evaluation
Counting functions
Continuous countingYes
Counter response parameterizableYes
Hardware gate via digital inputYes
Software gateYes
Event-controlled stopYes
Synchronization via digital inputYes
Counting range, parameterizableYes
Comparator
— Number of comparators2; per count channel; see manual for details
— Direction dependencyYes
— Can be changed from user programYes
Position detection
Incremental acquisitionYes
Suitable for S7-1500 Motion ControlYes
Measuring functions
Measuring time, parameterizableYes
Dynamic measurement period adjustmentYes
Number of thresholds, parameterizable2
Measuring range
— Frequency measurement, min.0.04 Hz
— Frequency measurement, max.400 kHz; with quadruple evaluation
— Cycle duration measurement, min.2.5 µs
— Cycle duration measurement, max.25 s
Accuracy
— Frequency measurement100 ppm; depending on measuring interval and signal evaluation
— Cycle duration measurement100 ppm; depending on measuring interval and signal evaluation
— Velocity measurement100 ppm; depending on measuring interval and signal evaluation
Potential separation digital inputs
between the channelsNo
between the channels, in groups of16
Potential separation digital outputs
between the channelsNo
between the channels, in groups of16
Potential separation channels
between the channels and backplane busYes
Between the channels and load voltage L+No
Isolation
Isolation tested with707 V DC (type test)
Standards, approvals, certificates
Recycler Guide availableYes
Ecological footprint
environmental product declarationYes
Global warming potential
— global warming potential, (total) [CO2 eq]199 kg
— global warming potential, (during production) [CO2 eq]71.5 kg
— global warming potential, (during operation) [CO2 eq]135 kg
— global warming potential, (after end of life cycle) [CO2 eq]-7.34 kg
Security
PROFINET Security Class1
Ambient temperature during operation
horizontal installation, min.-25 °C; No condensation
horizontal installation, max.60 °C; note derating data for onboard I/O in the manual. Display: 50 °C, at an operating temperature of typically 50 °C, the display is switched off
vertical installation, min.-25 °C; No condensation
vertical installation, max.40 °C; note derating data for onboard I/O in the manual. Display: 40 °C, at an operating temperature of typically 40 °C, the display is switched off
Ambient temperature during storage/transportation
min.-40 °C
max.70 °C
Altitude during operation relating to sea level
Installation altitude above sea level, max.5 000 m; Restrictions for installation altitudes > 2 000 m, see manual
Programming language
— LADYes
— FBDYes
— STLYes
— SCLYes
— GRAPHYes
Know-how protection
User program protection/password protectionYes
Copy protectionYes
Block protectionYes
Access protection
protection of confidential configuration dataYes
Password for displayYes
Protection level: Write protectionYes
Protection level: Read/write protectionYes
Protection level: Complete protectionYes
Cycle time monitoring
lower limitadjustable minimum cycle time
upper limitadjustable maximum cycle time
Dimensions
Width110 mm
Height147 mm
Depth129 mm
Weights
Weight, approx.1 360 g

Accessories 61

Genuine accessories that can be used with the Siemens 6ES7512-1CK01-0AB0 motor and are supplied separately are listed below. Click a code to open the accessory page and see the other compatible motors.

Part noDescriptionCompatible motors
6ES7972-0AB01-0XA0Aksesuar · Repeater bus components
3SK1122-2AB40Aksesuar · Safety relays
6ES7193-6SC20-1AM0Aksesuar · Accessories
6ES7972-0BB70-0XA0Aksesuar · PROFIBUS connector
6ES7972-0AA02-0XA0Aksesuar · Repeater bus components
6ES7193-6PA00-0AA0Aksesuar · spare part
6ES7193-6LR10-0AA0Aksesuar · label
6ES7193-6CP73-2AA0Aksesuar · label
6ES7193-6CP72-2AA0Aksesuar · label
6ES7193-6CP71-2AA0Aksesuar · label
6ES7193-6CP63-2MA0Aksesuar · label
6ES7193-6CP62-2MA0Aksesuar · label
6ES7193-6CP52-2MC0Aksesuar · label
6ES7193-6CP51-2MC0Aksesuar · label
6ES7193-6CP81-2AB0Aksesuar · label
6ES7193-6CP41-2MB0Aksesuar · label
6ES7193-6CP12-2MT0Aksesuar · label
6ES7193-6CP11-2MT0Aksesuar · label
6ES7193-6CP10-2MT0Aksesuar · label
6ES7193-6CP04-2MA0Aksesuar · label
6ES7193-6CP03-2MA0Aksesuar · label
6ES7193-6CP02-2MA0Aksesuar · label
6ES7193-6CP01-2MA0Aksesuar · label
6ES7193-6CP13-2MT0Aksesuar · label
6ES7193-6LR10-0AG0Aksesuar · label
6ES7193-6CP00-2MA0Aksesuar · label
6ES7193-6LF30-0AW0Aksesuar · label
6ES7193-6LA10-0AG0Aksesuar · label
6ES7193-6LA10-0AA0Aksesuar · label
6ES7193-6EH00-1AA0Aksesuar · spare part
6ES7193-6EF00-1AA0Aksesuar · spare part
6ES7193-6CP86-2AC0Aksesuar · label
6ES7193-6CP85-2AC0Aksesuar · label
6ES7193-6CP84-2AC0Aksesuar · label
6ES7193-6CP83-2AB0Aksesuar · label
6ES7193-6CP82-2AB0Aksesuar · label
6ES7954-8LC03-0AA0 Yedek parça · Memory card
6ES7954-8LE03-0AA0 Yedek parça · Memory card
6ES7954-8LF03-0AA0 Yedek parça · Memory card
6ES7954-8LT03-0AA0Yedek parça · Memory card
6ES7954-8LP03-0AA0 Yedek parça · Memory card
6ES7954-8LL03-0AA0 Yedek parça · Memory card
6ES7193-6MR00-0AA0Zorunlu ek ürün · Mounting rail
6ES7193-6MR00-0BA0Zorunlu ek ürün · Mounting rail
6ES7193-6MR00-0CA0Zorunlu ek ürün · Mounting rail
6ES7193-6MR00-0DA0Zorunlu ek ürün · Mounting rail
6ES7193-6AF00-0AA0Zorunlu ek ürün · BusAdapter
6ES7193-6AG00-0AA0Zorunlu ek ürün · BusAdapter
6ES7193-6AM00-0AA0Zorunlu ek ürün · BusAdapter
6ES7193-6AG20-0AA0Zorunlu ek ürün · BusAdapter
6ES7193-6AP00-0AA0Zorunlu ek ürün · BusAdapter
6ES7193-6AP20-0AA0Zorunlu ek ürün · BusAdapter
6ES7193-6AP40-0AA0Zorunlu ek ürün · BusAdapter
6ES7954-8LT04-0AA0Zorunlu ek ürün · Memory card
6ES7954-8LP04-0AA0Zorunlu ek ürün · Memory card
6ES7954-8LL04-0AA0Zorunlu ek ürün · Memory card
6ES7954-8LF04-0AA0Zorunlu ek ürün · Memory card
6ES7954-8LE04-0AA0Zorunlu ek ürün · Memory card
6ES7193-6AR00-0AA0Zorunlu ek ürün · BusAdapter
6ES7193-6AG40-0AA0Zorunlu ek ürün · BusAdapter
6ES7954-8LC04-0AA0Zorunlu ek ürün · Memory card

Related Products

1FN3003-0PB02-0AA3
Siemens 1FN3003-0PB02-0AA3
View Details

Siemens

1FN3003-0PB02-0AA3

MFR #1FN3003-0PB02-0AA3

SKU #YLS7ACYY31VH29I

1FN3003-0PB03-0AA3
Siemens 1FN3003-0PB03-0AA3
View Details

Siemens

1FN3003-0PB03-0AA3

MFR #1FN3003-0PB03-0AA3

SKU #YLSPDCXX5LUPVBP

1FN3003-0PB04-0BA3
Siemens 1FN3003-0PB04-0BA3
View Details

Siemens

1FN3003-0PB04-0BA3

MFR #1FN3003-0PB04-0BA3

SKU #YLSTLFTLVCKOIMT

1FN3003-0PB05-0BA3
Siemens 1FN3003-0PB05-0BA3
View Details

Siemens

1FN3003-0PB05-0BA3

MFR #1FN3003-0PB05-0BA3

SKU #YLS6EWIJX1ZRGHO

1FN3050-0TB00-1..0
Siemens 1FN3050-0TB00-1..0
View Details

Siemens

1FN3050-0TB00-1..0

MFR #1FN3050-0TB00-1..0

SKU #YLS5YVWHSMU6WB7

1FN3050-2NE00-0EA3
Siemens 1FN3050-2NE00-0EA3
View Details

Siemens

1FN3050-2NE00-0EA3

MFR #1FN3050-2NE00-0EA3

SKU #YLSE7XSY2HLF5EC

1FN3050-2NE00-0FA3
Siemens 1FN3050-2NE00-0FA3
View Details

Siemens

1FN3050-2NE00-0FA3

MFR #1FN3050-2NE00-0FA3

SKU #YLSMSUG5AP3INVD

1FN3100-0TB00-1..0
Siemens 1FN3100-0TB00-1..0
View Details

Siemens

1FN3100-0TB00-1..0

MFR #1FN3100-0TB00-1..0

SKU #YLSTD7J4JZ8UCBX

1FN3002-0TK03-1AF0
View Details

Siemens

1FN3002-0TK03-1AF0

MFR #1FN3002-0TK03-1AF0

SKU #YLS7VTGYJAP381B

1FN3050-1ND00-0HA3
View Details

Siemens

1FN3050-1ND00-0HA3

MFR #1FN3050-1ND00-0HA3

SKU #YLSJTX7SVU4GFKR

Featured Products

MY1M20-200AH
SMC MY1M20-200AH
View Details

SMC

MY1M20-200AH

MFR #MY1M20-200AH

SKU #YLSIZ8K8N4KBPBQ

VFSWDM3546T-5E
Baldor VFSWDM3546T-5E
View Details

Baldor

VFSWDM3546T-5E

MFR #VFSWDM3546T-5E

SKU #YLSRYYEFOOW6J5E

MXS-AS16L
SMC MXS-AS16L
View Details

SMC

MXS-AS16L

MFR #MXS-AS16L

SKU #YLSAP0XXFGFSWY6

AL30-03-8-A
SMC AL30-03-8-A
View Details

SMC

AL30-03-8-A

MFR #AL30-03-8-A

SKU #YLS6GDABZE4BN7A

CDJ2L16-125Z-B
SMC CDJ2L16-125Z-B
View Details

SMC

CDJ2L16-125Z-B

MFR #CDJ2L16-125Z-B

SKU #YLS5V0RW2VJJR1A

MTS32-150M
SMC MTS32-150M
View Details

SMC

MTS32-150M

MFR #MTS32-150M

SKU #YLSSJCSBTRLX2P7

ZCUKQ25-50D
SMC ZCUKQ25-50D
View Details

SMC

ZCUKQ25-50D

MFR #ZCUKQ25-50D

SKU #YLSQ684QXTNN958

SY5420-5DZ-01
SMC SY5420-5DZ-01
View Details

SMC

SY5420-5DZ-01

MFR #SY5420-5DZ-01

SKU #YLSQW9MERWL033X

NCDMC150-0600-X155US
SMC NCDMC150-0600-X155US
View Details

SMC

NCDMC150-0600-X155US

MFR #NCDMC150-0600-X155US

SKU #YLS8ICKGSKYC93L

Related Searches

Siemens 6ES7512-1CK01-0AB0 priceSiemens 6ES7512-1CK01-0AB0 quotebuy Siemens 6ES7512-1CK01-0AB06ES7512-1CK01-0AB0 price6ES7512-1CK01-0AB0 stock availabilitySiemens spare partsSiemens 6ES7512-1CK01-0AB0 equivalentSiemens 6ES7512-1CK01-0AB0 specifications