***spare part*** SIMATIC S7-300, CPU 314C-2 PTP compact CPU with MPI, 24 DI/16 DO, 4 AI, 2 AO, 1 Pt100, 4 high-speed counters (60 kHz), integrated interface RS485, integrated power supply 24 V DC, work memory 192 KB, front connector (2x 40-pole) and Micro Memory Card required

SiemensMFR # 6ES7314-6BH04-0AB0SKU # CEY-937FC77F5CC7
Product type designationCPU 314C-2 PtP
HW functional status01
Firmware versionV3.3
Rated value (DC)24 V
permissible range, lower limit (DC)19.2 V
permissible range, upper limit (DC)28.8 V
Share

About This Product

***spare part*** SIMATIC S7-300, CPU 314C-2 PTP compact CPU with MPI, 24 DI/16 DO, 4 AI, 2 AO, 1 Pt100, 4 high-speed counters (60 kHz), integrated interface RS485, integrated power supply 24 V DC, work memory 192 KB, front connector (2x 40-pole) and Micro Memory Card required

Siemens 6ES7314-6BH04-0AB0

  • Genuine, certified Siemens product
  • Fast sourcing through a worldwide supply network
  • Product selection and compatibility support from our technical team
  • Equivalent and alternative product suggestions
  • Quotation and lead time tailored to your request

Specifications

General information
Product type designationCPU 314C-2 PtP
HW functional status01
Firmware versionV3.3
Engineering with
Programming packageSTEP 7 as of V5.5 + SP1 or STEP 7 V5.3 + SP2 or higher with HSP 204
Supply voltage
Rated value (DC)24 V
permissible range, lower limit (DC)19.2 V
permissible range, upper limit (DC)28.8 V
external protection for power supply lines (recommendation)Miniature circuit breaker, type C; min. 2 A; miniature circuit breaker type B, min. 4 A
Mains buffering
Mains/voltage failure stored energy time5 ms
Repeat rate, min.1 s
Digital inputs
— Rated value (DC)24 V
— Reverse polarity protectionYes
Digital outputs
— Rated value (DC)24 V
— Reverse polarity protectionNo
Input current
Current consumption (rated value)660 mA
Current consumption (in no-load operation), typ.150 mA
Inrush current, typ.5 A
I²t0.7 A²·s
Digital inputs
from load voltage L+ (without load), max.80 mA
Digital outputs
from load voltage L+, max.50 mA
Power loss
Power loss, typ.13 W
Work memory
integrated192 kbyte
expandableNo
Load memory
Plug-in (MMC)Yes
Plug-in (MMC), max.8 Mbyte
Data management on MMC (after last programming), min.10 a
Backup
presentYes; Guaranteed by MMC (maintenance-free)
without batteryYes; Program and data
CPU processing times
for bit operations, typ.0.06 µs
for word operations, typ.0.12 µs
for fixed point arithmetic, typ.0.16 µs
for floating point arithmetic, typ.0.59 µs
CPU-blocks
Number of elements (total)1 024; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used.
DB
Number, max.1 024; Number range: 1 to 16000
Size, max.64 kbyte
FB
Number, max.1 024; Number range: 0 to 7999
Size, max.64 kbyte
FC
Number, max.1 024; Number range: 0 to 7999
Size, max.64 kbyte
OB
Number, max.see instruction list
Size, max.64 kbyte
Number of free cycle OBs1; OB 1
Number of time alarm OBs1; OB 10
Number of delay alarm OBs2; OB 20, 21
Number of cyclic interrupt OBs4; OB 32, 33, 34, 35
Number of process alarm OBs1; OB 40
Number of startup OBs1; OB 100
Number of asynchronous error OBs4; OB 80, 82, 85, 87
Number of synchronous error OBs2; OB 121, 122
Nesting depth
per priority class16
additional within an error OB4
S7 counter
Number256
Retentivity
— adjustableYes
— presetZ 0 to Z 7
Counting range
— lower limit0
— upper limit999
IEC counter
presentYes
TypeSFB
NumberUnlimited (limited only by RAM capacity)
S7 timer
Number256
Retentivity
— adjustableYes
— presetNo retentivity
Time range
— lower limit10 ms
— upper limit9 990 s
IEC timer
presentYes
TypeSFB
NumberUnlimited (limited only by RAM capacity)
Data areas and their retentivity
Retentive data area (incl. timers, counters, flags), max.64 kbyte
Flag
Size, max.256 byte
Retentivity availableYes; MB 0 to MB 255
Retentivity presetMB 0 to MB 15
Number of clock memories8; 1 memory byte
Data blocks
Retentivity adjustableYes; via non-retain property on DB
Retentivity presetYes
Local data
per priority class, max.32 kbyte; Max. 2048 bytes per block
I/O address area
Inputs1 024 byte
Outputs1 024 byte
of which distributed
— Inputsnone
— Outputsnone
Process image
Inputs1 024 byte
Outputs1 024 byte
Inputs, adjustable1 024 byte
Outputs, adjustable1 024 byte
Inputs, default128 byte
Outputs, default128 byte
Digital channels
Inputs1 016
— of which central1 016
Outputs1 008
— of which central1 008
Analog channels
Inputs253
— of which central253
Outputs250
— of which central250
Hardware configuration
Number of expansion units, max.3
Number of DP masters
integratednone
via CP4
Number of operable FMs and CPs (recommended)
FM8
CP, PtP8
CP, LAN10
Rack
Racks, max.4
Modules per rack, max.8; In rack 3 max. 7
Clock
Hardware clock (real-time)Yes
retentive and synchronizableYes
Backup time6 wk; At 40 °C ambient temperature
Deviation per day, max.10 s; Typ.: 2 s
Behavior of the clock following POWER-ONClock continues running after POWER OFF
Behavior of the clock following expiry of backup periodthe clock continues at the time of day it had when power was switched off
Operating hours counter
Number1
Number/Number range0
Range of values0 to 2^31 hours (when using SFC 101)
Granularity1 h
retentiveYes; Must be restarted at each restart
Clock synchronization
supportedYes
to MPI, masterYes
on MPI, deviceYes
in AS, masterYes
in AS, deviceNo
Digital inputs
Number of digital inputs24
of which inputs usable for technological functions16
integrated channels (DI)24
Input characteristic curve in accordance with IEC 61131, type 1Yes
horizontal installation
— up to 40 °C, max.24
— up to 60 °C, max.12
vertical installation
— up to 40 °C, max.12
Input voltage
Rated value (DC)24 V
for signal "0"-3 to +5V
for signal "1"+15 to +30 V
Input current
for signal "1", typ.8 mA
for standard inputs
— parameterizableYes; 0.1 / 0.3 / 3 / 15 ms (You can reconfigure the input delay of the standard inputs during program runtime. Please note that under certain circumstances your newly set filter time may not be effective until the next filter cycle.)
— Rated value3 ms
for technological functions
— at "0" to "1", max.8 µs; Minimum pulse width/minimum pause between pulses at maximum counting frequency
Cable length
shielded, max.1 000 m; 50 m for technological functions
unshielded, max.600 m; for technological functions: No
for technological functions
— shielded, max.50 m; at maximum count frequency
— unshielded, max.not allowed
Digital outputs
Number of digital outputs16
of which high-speed outputs4; Notice: You cannot connect the fast outputs of your CPU in parallel
integrated channels (DO)16
Short-circuit protectionYes; Clocked electronically
Response threshold, typ.1 A
Limitation of inductive shutdown voltage toL+ (-48 V)
Controlling a digital inputYes
Switching capacity of the outputs
on lamp load, max.5 W
Load resistance range
lower limit48 Ω
upper limit4 kΩ
Output voltage
for signal "1", min.L+ (-0.8 V)
Output current
for signal "1" rated value500 mA
for signal "1" permissible range, min.5 mA
for signal "1" permissible range, max.0.6 A
for signal "1" minimum load current5 mA
for signal "0" residual current, max.0.5 mA
Parallel switching of two outputs
for upratingNo
for redundant control of a loadYes
Switching frequency
with resistive load, max.100 Hz
with inductive load, max.0.5 Hz
on lamp load, max.100 Hz
of the pulse outputs, with resistive load, max.2.5 kHz
horizontal installation
— up to 40 °C, max.3 A
— up to 60 °C, max.2 A
vertical installation
— up to 40 °C, max.2 A
Cable length
shielded, max.1 000 m
unshielded, max.600 m
Analog inputs
Number of analog inputs5
For voltage/current measurement4
For resistance/resistance thermometer measurement1
integrated channels (AI)5; 4x current/voltage, 1x resistance
permissible input voltage for current input (destruction limit), max.5 V; Permanent
permissible input voltage for voltage input (destruction limit), max.30 V; Permanent
permissible input current for voltage input (destruction limit), max.0.5 mA; Permanent
permissible input current for current input (destruction limit), max.50 mA; Permanent
Electrical input frequency, max.400 Hz
No-load voltage for resistance-type transmitter, typ.3.3 V
Constant measurement current for resistance-type transmitter, typ.1.25 mA
Technical unit for temperature measurement adjustableYes; Degrees Celsius / degrees Fahrenheit / Kelvin
Input ranges
VoltageYes; ±10 V / 100 kΩ; 0 V to 10 V / 100 kΩ
CurrentYes; ±20 mA / 100 Ω; 0 mA to 20 mA / 100 Ω; 4 mA to 20 mA / 100 Ω
Resistance thermometerYes; Pt 100 / 10 MΩ
ResistanceYes; 0 Ω to 600 Ω / 10 MΩ
Input ranges (rated values), voltages
0 to +10 VYes
— Input resistance (0 to 10 V)100 kΩ
Input ranges (rated values), currents
0 to 20 mAYes
— Input resistance (0 to 20 mA)100 Ω
-20 mA to +20 mAYes
— Input resistance (-20 mA to +20 mA)100 Ω
4 mA to 20 mAYes
— Input resistance (4 mA to 20 mA)100 Ω
Input ranges (rated values), resistance thermometer
Pt 100Yes
— Input resistance (Pt 100)10 MΩ
Input ranges (rated values), resistors
0 to 600 ohmsYes
— Input resistance (0 to 600 ohms)10 MΩ
Temperature compensation
— ParameterizableNo
Characteristic linearization
ParameterizableYes; by software
— for resistance thermometerPt 100
Cable length
shielded, max.100 m
Analog outputs
integrated channels (AO)2
Voltage output, short-circuit protectionYes
Voltage output, short-circuit current, max.55 mA
Current output, no-load voltage, max.14 V
Output ranges, voltage
0 to 10 VYes
-10 V to +10 VYes
Output ranges, current
0 to 20 mAYes
-20 mA to +20 mAYes
4 mA to 20 mAYes
Connection of actuators
for voltage output two-wire connectionYes; Without compensation of the line resistances
for voltage output four-wire connectionNo
for current output two-wire connectionYes
Load impedance (in rated range of output)
with voltage outputs, min.1 kΩ
with voltage outputs, capacitive load, max.0.1 µF
with current outputs, max.300 Ω
with current outputs, inductive load, max.0.1 mH
Destruction limits against externally applied voltages and currents
Voltages at the outputs towards MANA16 V; Permanent
Current, max.50 mA; Permanent
Cable length
shielded, max.200 m
Analog value generation for the inputs
Measurement principleActual value encryption (successive approximation)
Integration and conversion time/resolution per channel
Resolution with overrange (bit including sign), max.12 bit
Integration time, parameterizableYes; 16.6 / 20 ms
Interference voltage suppression for interference frequency f1 in Hz50 / 60 Hz
Time constant of the input filter0.38 ms
Basic execution time of the module (all channels released)1 ms
Resolution with overrange (bit including sign), max.12 bit
Conversion time (per channel)1 ms
Settling time
for resistive load0.6 ms
for capacitive load1 ms
for inductive load0.5 ms
Connection of signal encoders
for voltage measurementYes
for current measurement as 2-wire transducerYes; with external supply
for current measurement as 4-wire transducerYes
for resistance measurement with two-wire connectionYes; Without compensation of the line resistances
for resistance measurement with three-wire connectionNo
for resistance measurement with four-wire connectionNo
Connectable encoders
2-wire sensorYes
— permissible quiescent current (2-wire sensor), max.1.5 mA
Errors/accuracies
Temperature error (relative to input range), (+/-)0.006 %/K
Crosstalk between the inputs, min.60 dB
Repeat accuracy in steady state at 25 °C (relative to input range), (+/-)0.06 %
Output ripple (relative to output range, bandwidth 0 to 50 kHz), (+/-)0.1 %
Linearity error (relative to output range), (+/-)0.15 %
Temperature error (relative to output range), (+/-)0.01 %/K
Crosstalk between the outputs, min.60 dB
Repeat accuracy in steady state at 25 °C (relative to output range), (+/-)0.06 %
Operational error limit in overall temperature range
Voltage, relative to input range, (+/-)1 %
Current, relative to input range, (+/-)1 %
Resistance, relative to input range, (+/-)1 %
Voltage, relative to output range, (+/-)1 %
Current, relative to output range, (+/-)1 %
Basic error limit (operational limit at 25 °C)
Voltage, relative to input range, (+/-)0.8 %; Linearity error ±0.06 %
Current, relative to input range, (+/-)0.8 %; Linearity error ±0.06 %
Resistance, relative to input range, (+/-)0.8 %; Linearity error ±0.2 %
Resistance thermometer, relative to input range, (+/-)0.8 %
Voltage, relative to output range, (+/-)0.8 %
Current, relative to output range, (+/-)0.8 %
Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency
Series mode interference (peak value of interference < rated value of input range), min.30 dB
Common mode interference, min.40 dB
Interfaces
Number of PROFINET interfaces0
Number of RS 485 interfaces1; MPI
Number of RS 422 interfaces1; RS 422 / 485 combined
Point-to-point connection
Cable length, max.1 200 m
Integrated protocol driver
— 3964 (R)Yes
— ASCIIYes
— RK 512Yes
Transmission rate, RS 422/485
— with 3964 (R) protocol, max.19.2 kbit/s; 38.4 kbit/s half duplex; 19.2 kbit/s full duplex
— with ASCII protocol, max.19.2 kbit/s; 38.4 kbit/s half duplex; 19.2 kbit/s full duplex
— with RK 512 protocol, max.19.2 kbit/s; 38.4 kbit/s half duplex; 19.2 kbit/s full duplex
1. Interface
Interface typeIntegrated RS 485 interface
IsolatedNo
Interface types
RS 485Yes
Output current of the interface, max.200 mA
Protocols
MPIYes
PROFIBUS DP masterNo
PROFIBUS DP deviceNo
Point-to-point connectionNo
MPI
Transmission rate, max.187.5 kbit/s
Services
— PG/OP communicationYes
— RoutingNo
— Global data communicationYes
— S7 basic communicationYes
— S7 communicationYes; Only server, configured on one side
— S7 communication, as clientNo; but via CP and loadable FB
— S7 communication, as serverYes
2. Interface
Interface typeIntegrated RS 422/ 485 interface
IsolatedYes
Interface types
RS 485Yes; RS 422 / 485 (X.27)
Output current of the interface, max.No
Protocols
MPINo
PROFINET IO ControllerNo
PROFINET IO DeviceNo
PROFINET CBANo
PROFIBUS DP masterNo
PROFIBUS DP deviceNo
Point-to-point connectionYes
Point-to-point connection
Transmission rate, max.19.2 kbit/s; 38.4 kbit/s half duplex; 19.2 kbit/s full duplex
Interface controllable from the user programYes
Interface can trigger alarm/interrupt in the user programYes; Message on break - identification
Protocols
PROFIsafeNo
Communication functions
PG/OP communicationYes
Data record routingNo
Global data communication
supportedYes
Number of GD loops, max.8
Number of GD packets, max.8
Number of GD packets, transmitter, max.8
Number of GD packets, receiver, max.8
Size of GD packets, max.22 byte
Size of GD packet (of which consistent), max.22 byte
S7 basic communication
supportedYes
User data per job, max.76 byte
User data per job (of which consistent), max.76 byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server)
S7 communication
supportedYes
as serverYes
as clientYes; Via CP and loadable FB
User data per job, max.180 kbyte; With PUT/GET
User data per job (of which consistent), max.240 byte; as server
S5 compatible communication
supportedYes; via CP and loadable FC
Number of connections
overall12
usable for PG communication11
— reserved for PG communication1
— adjustable for PG communication, min.1
— adjustable for PG communication, max.11
usable for OP communication11
— reserved for OP communication1
— adjustable for OP communication, min.1
— adjustable for OP communication, max.11
usable for S7 basic communication8
— reserved for S7 basic communication0
— adjustable for S7 basic communication, min.0
— adjustable for S7 basic communication, max.8
S7 message functions
Number of login stations for message functions, max.12; Depending on the configured connections for PG/OP and S7 basic communication
Process diagnostic messagesYes
simultaneously active Alarm_S blocks, max.300
Test commissioning functions
Status blockYes; Up to 2 simultaneously
Single stepYes
Number of breakpoints4
Status/control
Status/control variableYes
VariablesInputs, outputs, memory bits, DB, times, counters
Number of variables, max.30
— of which status variables, max.30
— of which control variables, max.14
Forcing
ForcingYes
Forcing, variablesInputs, outputs
Number of variables, max.10
Diagnostic buffer
presentYes
Number of entries, max.500
— adjustableNo
— of which powerfail-proof100; Only the last 100 entries are retained
Number of entries readable in RUN, max.499
— can be setYes; From 10 to 499
— preset10
Service data
Can be read outYes
Diagnostics indication LED
Status indicator digital input (green)Yes
Status indicator digital output (green)Yes
Integrated Functions
Number of counters4; See "Technological Functions" manual
Counting frequency, max.60 kHz
Frequency measurementYes
Number of frequency meters4; up to 60 kHz (see "Technological Functions" manual)
controlled positioningYes
integrated function blocks (closed-loop control)Yes; PID controller (see "Technological Functions" manual)
PID controllerYes
Number of pulse outputs4; Pulse width modulation up to 2.5 kHz (see "Technological Functions" Manual)
Limit frequency (pulse)2.5 kHz
Potential separation digital inputs
Potential separation digital inputsYes
between the channelsNo
between the channels and backplane busYes
Potential separation digital outputs
Potential separation digital outputsYes
between the channelsYes
between the channels, in groups of8
between the channels and backplane busYes
Potential separation analog inputs
Potential separation analog inputsYes; common for analog I/O
between the channelsNo
between the channels and backplane busYes
Potential separation analog outputs
Potential separation analog outputsYes; common for analog I/O
between the channelsNo
between the channels and backplane busYes
Isolation
Isolation tested with600 V DC
Ambient temperature during operation
min.0 °C
max.60 °C
Configuration software
STEP 7Yes; STEP 7 V5.5 + SP1 or higher or STEP 7 V5.3 + SP2 or higher with HSP 203
STEP 7 LiteNo
Programming
Command setsee instruction list
Nesting levels8
System functions (SFC)see instruction list
System function blocks (SFB)see instruction list
Programming language
— LADYes
— FBDYes
— STLYes
— SCLYes
— CFCYes
— GRAPHYes
— HiGraph®Yes
Know-how protection
User program protection/password protectionYes
Block encryptionYes; With S7 block Privacy
Dimensions
Width120 mm
Height125 mm
Depth130 mm
Weights
Weight, approx.680 g

Accessories 2

Genuine accessories that can be used with the Siemens 6ES7314-6BH04-0AB0 motor and are supplied separately are listed below. Click a code to open the accessory page and see the other compatible motors.

Part noDescriptionCompatible motors
9LF1110-6DA13-2AB1Servis · Service Card
9TF6276-2XA11-1AL4Servis

Related Products

1FN3003-0PB02-0AA3
Siemens 1FN3003-0PB02-0AA3
View Details

Siemens

1FN3003-0PB02-0AA3

MFR #1FN3003-0PB02-0AA3

SKU #YLS7ACYY31VH29I

1FN3003-0PB03-0AA3
Siemens 1FN3003-0PB03-0AA3
View Details

Siemens

1FN3003-0PB03-0AA3

MFR #1FN3003-0PB03-0AA3

SKU #YLSPDCXX5LUPVBP

1FN3003-0PB04-0BA3
Siemens 1FN3003-0PB04-0BA3
View Details

Siemens

1FN3003-0PB04-0BA3

MFR #1FN3003-0PB04-0BA3

SKU #YLSTLFTLVCKOIMT

1FN3003-0PB05-0BA3
Siemens 1FN3003-0PB05-0BA3
View Details

Siemens

1FN3003-0PB05-0BA3

MFR #1FN3003-0PB05-0BA3

SKU #YLS6EWIJX1ZRGHO

1FN3050-0TB00-1..0
Siemens 1FN3050-0TB00-1..0
View Details

Siemens

1FN3050-0TB00-1..0

MFR #1FN3050-0TB00-1..0

SKU #YLS5YVWHSMU6WB7

1FN3050-2NE00-0EA3
Siemens 1FN3050-2NE00-0EA3
View Details

Siemens

1FN3050-2NE00-0EA3

MFR #1FN3050-2NE00-0EA3

SKU #YLSE7XSY2HLF5EC

1FN3050-2NE00-0FA3
Siemens 1FN3050-2NE00-0FA3
View Details

Siemens

1FN3050-2NE00-0FA3

MFR #1FN3050-2NE00-0FA3

SKU #YLSMSUG5AP3INVD

1FN3100-0TB00-1..0
Siemens 1FN3100-0TB00-1..0
View Details

Siemens

1FN3100-0TB00-1..0

MFR #1FN3100-0TB00-1..0

SKU #YLSTD7J4JZ8UCBX

1FN3002-0TK03-1AF0
View Details

Siemens

1FN3002-0TK03-1AF0

MFR #1FN3002-0TK03-1AF0

SKU #YLS7VTGYJAP381B

1FN3050-1ND00-0HA3
View Details

Siemens

1FN3050-1ND00-0HA3

MFR #1FN3050-1ND00-0HA3

SKU #YLSJTX7SVU4GFKR

Featured Products

CM2B40-75Z
SMC CM2B40-75Z
View Details

SMC

CM2B40-75Z

MFR #CM2B40-75Z

SKU #YLSOGLJ512KWTEJ

AW20-N02CG-6CZ-B
SMC AW20-N02CG-6CZ-B
View Details

SMC

AW20-N02CG-6CZ-B

MFR #AW20-N02CG-6CZ-B

SKU #YLSNOOF0IBCZ3J3

AR30-N02E-1Z-B
SMC AR30-N02E-1Z-B
View Details

SMC

AR30-N02E-1Z-B

MFR #AR30-N02E-1Z-B

SKU #YLSYFNHADE6GRKV

MY1M20-200AH
SMC MY1M20-200AH
View Details

SMC

MY1M20-200AH

MFR #MY1M20-200AH

SKU #YLSIZ8K8N4KBPBQ

MDBB63-100Z
SMC MDBB63-100Z
View Details

SMC

MDBB63-100Z

MFR #MDBB63-100Z

SKU #YLSNBPQBGLI90UX

EH22512
Danfoss Aeroquip LLC EH22512
View Details

Danfoss Aeroquip LLC

EH22512

MFR #EH22512

SKU #YLSRZ91UGVO64DG

AL30-03-8-A
SMC AL30-03-8-A
View Details

SMC

AL30-03-8-A

MFR #AL30-03-8-A

SKU #YLS6GDABZE4BN7A

VQZ2121-5LO1-N3T
SMC VQZ2121-5LO1-N3T
View Details

SMC

VQZ2121-5LO1-N3T

MFR #VQZ2121-5LO1-N3T

SKU #YLSEL35MGGQ9FOL

MTS32-150M
SMC MTS32-150M
View Details

SMC

MTS32-150M

MFR #MTS32-150M

SKU #YLSSJCSBTRLX2P7

Related Searches

Siemens 6ES7314-6BH04-0AB0 priceSiemens 6ES7314-6BH04-0AB0 quotebuy Siemens 6ES7314-6BH04-0AB06ES7314-6BH04-0AB0 price6ES7314-6BH04-0AB0 stock availabilitySiemens spare partsSiemens 6ES7314-6BH04-0AB0 equivalentSiemens 6ES7314-6BH04-0AB0 specifications