Siemens 6ES7215-1BG40-0XB0

Photo may not represent actual item. Refer to name and product specs for all details.

Siemens 6ES7215-1BG40-0XB0

SIMATIC S7-1200, CPU 1215C, compact CPU, AC/DC/relay, 2 PROFINET ports, onboard I/O: 14 DI 24 V DC; 10 DO relay 2 A, 2 AI 0-10 V DC, 2 AO 0-20 mA DC, power supply: AC 85-264 V AC at 47-63 Hz, program/data memory 200 KB

SiemensMFR # 6ES7215-1BG40-0XB0SKU # CEY-937FC77E5EB1
Product type designationCPU 1215C AC/DC/relay
Firmware versionV4.7
Programming packageSTEP 7 V20 or higher
120 V ACYes
230 V ACYes
permissible range, lower limit (AC)85 V
Share

About This Product

SIMATIC S7-1200, CPU 1215C, compact CPU, AC/DC/relay, 2 PROFINET ports, onboard I/O: 14 DI 24 V DC; 10 DO relay 2 A, 2 AI 0-10 V DC, 2 AO 0-20 mA DC, power supply: AC 85-264 V AC at 47-63 Hz, program/data memory 200 KB

Siemens 6ES7215-1BG40-0XB0

  • Genuine, certified Siemens product
  • Fast sourcing through a worldwide supply network
  • Product selection and compatibility support from our technical team
  • Equivalent and alternative product suggestions
  • Quotation and lead time tailored to your request

Specifications

General information
Product type designationCPU 1215C AC/DC/relay
Firmware versionV4.7
Engineering with
Programming packageSTEP 7 V20 or higher
Supply voltage
120 V ACYes
230 V ACYes
permissible range, lower limit (AC)85 V
permissible range, upper limit (AC)265 V
Line frequency
permissible range, lower limit47 Hz
permissible range, upper limit63 Hz
Input current
Current consumption (rated value)100 mA at 120 V AC; 50 mA at 240 V AC
Current consumption, max.300 mA at 120 V AC; 150 mA at 240 V AC
Inrush current, max.20 A; at 264 V
I²t0.8 A²·s
Output current
for backplane bus (5 V DC), max.1 600 mA; Max. 5 V DC for SM and CM
24 V encoder supply
24 V20.4 to 28.8V
Power loss
Power loss, typ.14 W
Work memory
integrated200 kbyte
Load memory
Integrated4 Mbyte
Plug-in (SIMATIC Memory Card), max.with SIMATIC memory card
Backup
presentYes
maintenance-freeYes
without batteryYes
CPU processing times
for bit operations, typ.0.08 µs; / instruction
for word operations, typ.1.7 µs; / instruction
for floating point arithmetic, typ.2.3 µs; / instruction
CPU-blocks
Number of elements (total)DBs, FCs, FBs, counters and timers. The maximum number of addressable blocks ranges from 1 to 65535. There is no restriction, the entire working memory can be used
OB
Number, max.Limited only by RAM for code
Data areas and their retentivity
Retentive data area (incl. timers, counters, flags), max.14 kbyte
Flag
Size, max.8 kbyte; Size of bit memory address area
Local data
per priority class, max.16 kbyte; Priority class 1 (program cycle): 16 KB, priority class 2 to 26: 6 KB
Process image
Inputs, adjustable1 kbyte
Outputs, adjustable1 kbyte
Hardware configuration
Number of modules per system, max.3 comm. modules, 1 signal board, 8 signal modules
number of expansion boards (SB, CB, BB)1
number of signal modules (SM)8
number of communications modules (CM)3
Clock
Hardware clock (real-time)Yes
Backup time480 h; Typical
Deviation per day, max.±60 s/month at 25 °C
Digital inputs
Number of digital inputs14; Integrated
of which inputs usable for technological functions6; HSC (High Speed Counting)
Sourcing/sinking inputYes
all mounting positions
— up to 40 °C, max.14
Input voltage
Rated value (DC)24 V
for signal "0"5 V DC at 1 mA
for signal "1"15 V DC at 2.5 mA
for standard inputs
— parameterizableYes; 0.1 / 0.2 / 0.4 / 0.8 / 1.6 / 3.2 / 6.4 / 10.0 / 12.8 / 20.0 μs; 0.05 / 0.1 / 0.2 / 0.4 / 0.8 / 1.6 / 3.2 / 6.4 / 10.0 / 12.8 / 20.0 ms
— at "0" to "1", min.0.2 ms
— at "0" to "1", max.12.8 ms
for interrupt inputs
— ParameterizableYes
for technological functions
— ParameterizableSingle phase: 3 @ 100 kHz & 3 @ 30 kHz, differential: 3 @ 80 kHz & 3 @ 30 kHz
Cable length
shielded, max.500 m; 50 m for technological functions
unshielded, max.300 m; for technological functions: No
Digital outputs
Number of digital outputs10; Relays
Switching capacity of the outputs
with resistive load, max.2 A
on lamp load, max.30 W with DC, 200 W with AC
Output delay with resistive load
"0" to "1", max.10 ms; max.
"1" to "0", max.10 ms; max.
Relay outputs
Number of relay outputs10
Number of operating cycles, max.mechanically 10 million, at rated load voltage 100 000
Cable length
shielded, max.500 m
unshielded, max.150 m
Analog inputs
Number of analog inputs2
Input ranges
VoltageYes
Input ranges (rated values), voltages
0 to +10 VYes
— Input resistance (0 to 10 V)≥100k ohms
Cable length
shielded, max.100 m; twisted and shielded
Analog outputs
Number of analog outputs2
Output ranges, current
0 to 20 mAYes
Integration and conversion time/resolution per channel
Resolution with overrange (bit including sign), max.10 bit
Integration time, parameterizableYes
Conversion time (per channel)625 µs
Connectable encoders
2-wire sensorYes
Interfaces
Number of PROFINET interfaces1
1. Interface
Interface typePROFINET
IsolatedYes
automatic detection of transmission rateYes
AutonegotiationYes
AutocrossingYes
Interface types
RJ 45 (Ethernet)Yes
Number of ports2
integrated switchYes
Protocols
PROFINET IO ControllerYes
PROFINET IO deviceYes
SIMATIC communicationYes
Open IE communicationYes; Optionally also encrypted
Web serverYes
Media redundancyYes
PROFINET IO Controller
Transmission rate, max.100 Mbit/s
Services
— PG/OP communicationYes; encryption with TLS V1.3 pre-selected
— Isochronous modeNo
— IRTNo
— PROFIenergyNo
— Prioritized startupYes
— Number of IO devices with prioritized startup, max.16
— Number of connectable IO Devices, max.16
— Number of connectable IO Devices for RT, max.16
— of which in line, max.16
— Number of IO Devices that can be simultaneously activated/deactivated, max.8
— Updating timeThe minimum value of the update time also depends on the communication component set for PROFINET IO, on the number of IO devices and the quantity of configured user data.
— PG/OP communicationYes; encryption with TLS V1.3 pre-selected
— Isochronous modeNo
— IRTNo
— Dynamic Frame Packing (DFP)No
— PROFIenergyYes
— Prioritized startupYes
— Shared deviceYes
— Number of IO Controllers with shared device, max.2
— Asset management recordYes
Protocols
Supports protocol for PROFINET IOYes
PROFIsafeNo
PROFIBUSYes; CM 1243-5 (master) or CM 1242-5 (slave) required
OPC UAYes; OPC UA Server
AS-InterfaceYes; CM 1243-2 required
Protocols (Ethernet)
TCP/IPYes
DHCPNo
SNMPYes
DCPYes
LLDPYes
Redundancy mode
PROFINET system redundancy (S2)No
PROFINET system redundancy (R1)No
Media redundancy
— MRPYes; as MRP redundancy manager and/or MRP client
— MRP interconnection, supportedNo
— MRPDNo
SIMATIC communication
S7 routingYes
Open IE communication
TCP/IPYes
— Data length, max.8 kbyte
ISO-on-TCP (RFC1006)Yes
— Data length, max.8 kbyte
UDPYes
— Data length, max.1 472 byte
Web server
supportedYes
User-defined websitesYes
OPC UA
Runtime license requiredYes; "Basic" license required
OPC UA ServerYes; data access (read, write, subscribe), method call, runtime license required
— Application authenticationAvailable security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256
— User authentication"anonymous" or by user name & password
— Number of sessions, max.10
— Number of subscriptions per session, max.5
— Sampling interval, min.100 ms
— Publishing interval, min.200 ms
— Number of server methods, max.20
— Number of monitored items, recommended max.1 000
— Number of server interfaces, max.2
— Number of nodes for user-defined server interfaces, max.2 000
Further protocols
MODBUSYes
S7 communication
supportedYes
as serverYes
as clientYes
User data per job, max.See online help (S7 communication, user data size)
Number of connections
overallPG Connections: 4 reserved / 4 max; HMI Connections: 12 reserved / 18 max; S7 Connections: 8 reserved / 14 max; Open User Connections: 8 reserved / 14 max; Web Connections: 2 reserved / 30 max; OPC UA Connections: 0 reserved / 10 max; Total Connections: 34 reserved / 68 max
Status/control
Status/control variableYes
VariablesInputs/outputs, memory bits, DBs, distributed I/Os, timers, counters
Forcing
ForcingYes
Diagnostic buffer
presentYes
Traces
Number of configurable Traces2
Memory size per trace, max.512 kbyte
Diagnostics indication LED
RUN/STOP LEDYes
ERROR LEDYes
MAINT LEDYes
Integrated Functions
Number of counters6
Counting frequency, max.100 kHz
Frequency measurementYes
controlled positioningYes
Number of position-controlled positioning axes, max.8
Number of positioning axes via pulse-direction interfaceUp to 4 with SB 1222
PID controllerYes
Number of alarm inputs4
Potential separation digital inputs
Potential separation digital inputs500 V AC for 1 minute
between the channels, in groups of1
Potential separation digital outputs
Potential separation digital outputsRelays
between the channelsNo
between the channels, in groups of2
Interference immunity against discharge of static electricity
Interference immunity against discharge of static electricity acc. to IEC 61000-4-2Yes
— Test voltage at air discharge8 kV
— Test voltage at contact discharge6 kV
Interference immunity to cable-borne interference
Interference immunity on supply lines acc. to IEC 61000-4-4Yes
Interference immunity on signal cables acc. to IEC 61000-4-4Yes
Interference immunity against voltage surge
Interference immunity on supply lines acc. to IEC 61000-4-5Yes
Interference immunity against conducted variable disturbance induced by high-frequency fields
Interference immunity against high-frequency radiation acc. to IEC 61000-4-6Yes
Emission of radio interference acc. to EN 55 011
Limit class A, for use in industrial areasYes; Group 1
Limit class B, for use in residential areasYes; When appropriate measures are used to ensure compliance with the limits for Class B according to EN 55011
Degree and class of protection
IP degree of protectionIP20
Standards, approvals, certificates
Siemens Eco Profile (SEP)Siemens EcoTech
CE markYes
UL approvalYes
cULusYes
FM approvalYes
RCM (formerly C-TICK)Yes
KC approvalYes
Marine approvalYes
Ecological footprint
environmental product declarationYes; type II acc. to ISO 14021
Global warming potential
— global warming potential, (total) [CO2 eq]106 kg
— global warming potential, (during production) [CO2 eq]18.5 kg
— global warming potential, (during operation) [CO2 eq]88.2 kg
— global warming potential, (after end of life cycle) [CO2 eq]-1.1 kg
Free fall
Fall height, max.0.3 m; five times, in product package
Ambient temperature during operation
min.-20 °C
max.60 °C; Number of simultaneously activated inputs or outputs 7 or 5 (no adjacent points) at 60 °C horizontal or 50 °C vertical, 14 or 10 at 55 °C horizontal or 45 °C vertical
horizontal installation, min.-20 °C
horizontal installation, max.60 °C
vertical installation, min.-20 °C
vertical installation, max.50 °C
Ambient temperature during storage/transportation
min.-40 °C
max.70 °C
Air pressure acc. to IEC 60068-2-13
Operation, min.795 hPa
Operation, max.1 080 hPa
Storage/transport, min.660 hPa
Storage/transport, max.1 080 hPa
Altitude during operation relating to sea level
Installation altitude, min.-1 000 m
Installation altitude, max.5 000 m; Restrictions for installation altitudes > 2 000 m, see manual
Relative humidity
Operation, max.95 %; no condensation
Vibrations
Vibration resistance during operation acc. to IEC 60068-2-62 g (m/s²) wall mounting, 1 g (m/s²) DIN rail
Operation, tested according to IEC 60068-2-6Yes
Shock testing
tested according to IEC 60068-2-27Yes; IEC 68, Part 2-27 half-sine: strength of the shock 15 g (peak value), duration 11 ms
Pollutant concentrations
SO2 at RH < 60% without condensationS02: < 0.5 ppm; H2S: < 0.1 ppm; RH < 60 % condensation-free
Programming language
— LADYes
— FBDYes
— SCLYes
Know-how protection
User program protection/password protectionYes
Copy protectionYes
Block protectionYes
Access protection
protection of confidential configuration dataYes
Protection level: Write protectionYes
Protection level: Read/write protectionYes
Protection level: Complete protectionYes
User administrationYes; device-wide
Number of users42
Number of groups14
Number of roles20
Cycle time monitoring
can be setYes
Dimensions
Width130 mm
Height100 mm
Depth75 mm
Weights
Weight, approx.550 g

Related Products

1FN3003-0PB02-0AA3
Siemens 1FN3003-0PB02-0AA3
View Details

Siemens

1FN3003-0PB02-0AA3

MFR #1FN3003-0PB02-0AA3

SKU #YLS7ACYY31VH29I

1FN3003-0PB03-0AA3
Siemens 1FN3003-0PB03-0AA3
View Details

Siemens

1FN3003-0PB03-0AA3

MFR #1FN3003-0PB03-0AA3

SKU #YLSPDCXX5LUPVBP

1FN3003-0PB04-0BA3
Siemens 1FN3003-0PB04-0BA3
View Details

Siemens

1FN3003-0PB04-0BA3

MFR #1FN3003-0PB04-0BA3

SKU #YLSTLFTLVCKOIMT

1FN3003-0PB05-0BA3
Siemens 1FN3003-0PB05-0BA3
View Details

Siemens

1FN3003-0PB05-0BA3

MFR #1FN3003-0PB05-0BA3

SKU #YLS6EWIJX1ZRGHO

1FN3050-0TB00-1..0
Siemens 1FN3050-0TB00-1..0
View Details

Siemens

1FN3050-0TB00-1..0

MFR #1FN3050-0TB00-1..0

SKU #YLS5YVWHSMU6WB7

1FN3050-2NE00-0EA3
Siemens 1FN3050-2NE00-0EA3
View Details

Siemens

1FN3050-2NE00-0EA3

MFR #1FN3050-2NE00-0EA3

SKU #YLSE7XSY2HLF5EC

1FN3050-2NE00-0FA3
Siemens 1FN3050-2NE00-0FA3
View Details

Siemens

1FN3050-2NE00-0FA3

MFR #1FN3050-2NE00-0FA3

SKU #YLSMSUG5AP3INVD

1FN3100-0TB00-1..0
Siemens 1FN3100-0TB00-1..0
View Details

Siemens

1FN3100-0TB00-1..0

MFR #1FN3100-0TB00-1..0

SKU #YLSTD7J4JZ8UCBX

1FN3002-0TK03-1AF0
View Details

Siemens

1FN3002-0TK03-1AF0

MFR #1FN3002-0TK03-1AF0

SKU #YLS7VTGYJAP381B

1FN3050-1ND00-0HA3
View Details

Siemens

1FN3050-1ND00-0HA3

MFR #1FN3050-1ND00-0HA3

SKU #YLSJTX7SVU4GFKR

Featured Products

NCDMC150-0600-X155US
SMC NCDMC150-0600-X155US
View Details

SMC

NCDMC150-0600-X155US

MFR #NCDMC150-0600-X155US

SKU #YLS8ICKGSKYC93L

MGPM25-100Z-XC4
SMC MGPM25-100Z-XC4
View Details

SMC

MGPM25-100Z-XC4

MFR #MGPM25-100Z-XC4

SKU #YLSH71U0VZZBO5I

NCDJ2L10-300-B
SMC NCDJ2L10-300-B
View Details

SMC

NCDJ2L10-300-B

MFR #NCDJ2L10-300-B

SKU #YLSRRDWPL50RWQ2

NCMC150-0600-X103US
SMC NCMC150-0600-X103US
View Details

SMC

NCMC150-0600-X103US

MFR #NCMC150-0600-X103US

SKU #YLS468HQT0B65QG

VQZ2121-5LO1-N3T
SMC VQZ2121-5LO1-N3T
View Details

SMC

VQZ2121-5LO1-N3T

MFR #VQZ2121-5LO1-N3T

SKU #YLSEL35MGGQ9FOL

BC8M12
Brush Research Mfg BC8M12
View Details

Brush Research Mfg

BC8M12

MFR #BC8M12

SKU #YLSA0P5BE6ZJCIW

MGPL25TN-200BZ-XC9
SMC MGPL25TN-200BZ-XC9
View Details

SMC

MGPL25TN-200BZ-XC9

MFR #MGPL25TN-200BZ-XC9

SKU #YLSPBI637NOCN0Y

MY1M20-200AH
SMC MY1M20-200AH
View Details

SMC

MY1M20-200AH

MFR #MY1M20-200AH

SKU #YLSIZ8K8N4KBPBQ

SY5420-5DZ-01
SMC SY5420-5DZ-01
View Details

SMC

SY5420-5DZ-01

MFR #SY5420-5DZ-01

SKU #YLSQW9MERWL033X

Related Searches

Siemens 6ES7215-1BG40-0XB0 priceSiemens 6ES7215-1BG40-0XB0 quotebuy Siemens 6ES7215-1BG40-0XB06ES7215-1BG40-0XB0 price6ES7215-1BG40-0XB0 stock availabilitySiemens spare partsSiemens 6ES7215-1BG40-0XB0 equivalentSiemens 6ES7215-1BG40-0XB0 specifications