General information
HW functional statusFS01
Firmware versionV1.1.x
FW update possibleYes
Vendor identification (VendorID)002AH
Device identifier (DeviceID)031AH
Manufacturer ID according to ODVA (VendorID)04E3H
Device ID according to ODVA (Product code)0FB8H
Product function
I&M dataYes; I&M0 to I&M3
Isochronous modeNo
IRTYes
Prioritized startupYes
Engineering with
STEP 7 TIA Portal configurable/integrated from versionSTEP 7 V19 or higher with HSP 0414
PROFINET from GSD version/GSD revisionGSDML V2.4.x
Multi Fieldbus Configuration Tool (MFCT)V1.5.x or higher
Operating mode
DIYes
CounterNo
DQYes
MSIYes
MSOYes
Supply voltage
power supply according to NEC Class 2 requiredNo
Load voltage 1L+
Rated value (DC)24 V
permissible range, lower limit (DC)20.4 V
permissible range, upper limit (DC)28.8 V
Reverse polarity protectionYes; Against destruction; encoder power supply outputs applied with reversed polarity, loads pick up
Load voltage 2L+
Rated value (DC)24 V
permissible range, lower limit (DC)20.4 V
permissible range, upper limit (DC)28.8 V
Reverse polarity protectionYes; Against destruction; encoder power supply outputs applied with reversed polarity, loads pick up
Input current
Current consumption (rated value)95 mA; without load
from load voltage 1L+ (unswitched voltage)12 A; Maximum value
from load voltage 2L+, max.12 A; Maximum value
Encoder supply
Number of outputs8
24 V encoder supply
Short-circuit protectionYes; Group-by-group for 2 channels, electronic
Output current, max.100 mA; per output
Power loss
Power loss, typ.5.5 W
Address space per module
Inputs2 byte; + 4 bytes for QI information
Outputs2 byte
Submodules
Number of configurable submodules, max.2
Digital inputs
Number of digital inputs16; Parameterizable as DIQ
in groups of8
Digital inputs, parameterizableYes
Sourcing/sinking inputP-reading
Input characteristic curve in accordance with IEC 61131, type 3Yes
all mounting positions
— up to 55 °C, max.16
Input voltage
Rated value (DC)24 V
for signal "0"-3 to +5V
for signal "1"+11 to +30V
Input current
for signal "1", typ.2.4 mA
for standard inputs
— parameterizableYes; 0.05 / 0.1 / 0.4 / 0.8 / 1.6 / 3.2 / 12.8 / 20 ms
Cable length
unshielded, max.30 m
Digital outputs
Number of digital outputs16; Parameterizable as DIQ
in groups of8; 2 load groups for 8 outputs each
Current-sourcingYes
output type acc. to IEC 61131, type 0.5Yes
Short-circuit protectionYes; per channel, electronic
Response threshold, typ.1 A
Limitation of inductive shutdown voltage totyp. L+ (-70 V)
Controlling a digital inputYes
Switching capacity of the outputs
with resistive load, max.0.5 A
with inductive load, max.0.5 A
on lamp load, max.5 W
Load resistance range
lower limit48 Ω
upper limit4 kΩ
Output voltage
for signal "1", min.1L+ (-0.8 V) / 2L+ (-0.8 V)
Output current
for signal "1" rated value0.5 A
for signal "1" permissible range, max.0.5 A
for signal "0" residual current, max.0.1 mA
Output delay with resistive load
"0" to "1", max.100 µs; at rated load
"1" to "0", max.1L+: 100 µs / 2L+: 3 ms; at rated load
Parallel switching of two outputs
for upratingNo
for redundant control of a loadYes
Switching frequency
with resistive load, max.100 Hz
with inductive load, max.0.5 Hz
on lamp load, max.1 Hz
Total current of the outputs
Current per group, max.4 A
Current per module, max.8 A
Cable length
unshielded, max.30 m
Connectable encoders
2-wire sensorYes
— permissible quiescent current (2-wire sensor), max.1.5 mA
Interfaces
Number of PROFINET interfaces1
1. Interface
Interface typePROFINET with 100 Mbit/s full duplex (100BASE-TX)
Interface types
M12 portYes; 2x M12, 4-pin, D-coded
Number of ports2
integrated switchYes
Protocols
PROFINET IO DeviceYes
Open IE communicationYes
Services
— IRTYes; 250 µs to 4 ms in 125 µs frame
— Prioritized startupYes
— Shared deviceYes
— Number of IO Controllers with shared device, max.2
M12 port
AutonegotiationYes
AutocrossingYes
Transmission rate, max.100 Mbit/s
Protocols
Supports protocol for PROFINET IOYes
PROFIsafeNo
EtherNet/IPYes
Modbus TCPYes
Redundancy mode
PROFINET system redundancy (S2)Yes
— on S7-1500R/HYes
— on S7-400HYes
PROFINET system redundancy (R1)No
H-Sync forwardingYes
Media redundancy
— MRPYes
— MRPDNo
Services
— CIP Implicit MessagingYes
— CIP Explicit MessagingYes
— CIP SafetyNo
— Shared deviceYes; 2x EtherNet/IP Scanner
— Number of scanners with shared device, max.2
Updating times
— Requested Packet Interval (RPI)2 ms
Redundancy mode
— DLR (Device Level Ring)No
Address area
— Address space per module, max.20 byte
— LargeForwardOpen (Class3)No
Services
— read coils (code=1)Yes
— read discrete inputs (code=2)Yes
— Read Holding Registers (Code=3)Yes
— write single coil (code=5)Yes
— write multiple coils (code=15)Yes
— Write Multiple Registers (Code=16)Yes
— Parameter change by masterNo
— Modbus TCP Security ProtocolNo
Address space per station
— Address space per station, max.20 byte
— Access-consistent address space2 byte
Updating time
— I/O request interval2 ms
Connections
— number of connections per device12
Open IE communication
TCP/IPYes; (only EtherNet/IP or Modbus TCP)
SNMPYes
LLDPYes
ARPYes
Interrupts/diagnostics/status information
Substitute values connectableYes
Alarms
Diagnostic alarmYes; Parameterizable
Maintenance interruptYes; Parameterizable
Hardware interruptYes; Parameterizable
Diagnoses
Diagnostic information readableYes
Monitoring the supply voltageYes
— ParameterizableYes
Wire breakYes; DI, input current < 0.3 mA, per channel
short-circuitYes; Outputs to M and P; channel by channel
Short-circuit encoder supplyYes; Per channel group
Diagnostics indication LED
RUN LEDYes; green LED
ERROR LEDYes; red LED
MAINT LEDYes; Yellow LED
NS LEDYes; green/red LED
MS LEDYes; green/red LED
IO LEDYes; red/green/yellow LEDs
Channel status displayYes; green LED
for channel diagnosticsYes; red LED
For load voltage monitoringYes; green LED
Connection display LINK TX/RXYes; green LED, only link
Potential separation
between the load voltagesYes
between Ethernet and electronicsYes
Potential separation channels
between the channelsYes
between the channels, in groups of8
between the channels and the power supply of the electronics8 channels are non-isolated and 8 channels are isolated from supply voltage 1L+
tested with
24 V DC circuits707 V DC (type test)
Test voltage for interface, rms value [Vrms]1 500 V; According to IEEE 802.3
Degree and class of protection
IP degree of protectionIP65/67/69K
Standards, approvals, certificates
Siemens Eco Profile (SEP)Siemens EcoTech
Suitable for safety-related tripping of standard modulesYes; from FS01
Ecological footprint
environmental product declarationYes
Global warming potential
— global warming potential, (total) [CO2 eq]64.3 kg
— global warming potential, (during production) [CO2 eq]10.9 kg
— global warming potential, (during operation) [CO2 eq]53.8 kg
— global warming potential, (after end of life cycle) [CO2 eq]-0.521 kg
Highest safety class achievable for safety-related tripping of standard modules
Performance level according to ISO 13849-1PL d
Category according to ISO 13849-1Cat. 3
SIL acc. to IEC 62061SIL 2
Security
signed firmware updateYes
safely removing dataYes
Ambient temperature during operation
min.-30 °C
max.55 °C
Altitude during operation relating to sea level
Ambient air temperature-barometric pressure-altitudeUp to max. 5 000 m, at installation height > 2 000 m additional restrictions
Absolute humidity
dew point, min.-60 °C; suitable for dry room applications
Connection method
Design of electrical connection4/5-pin M12 circular connectors
Design of electrical connection for the inputs and outputsM12, 5-pin, A-coded
Design of electrical connection for supply voltageM12, 4-pin, L-coded
Mechanics/material
Materialhousing: PBT; seal: MVQ (silicone); bushing / metal parts: 1.4404 (stainless steel)
Dimensions
Width80 mm
Height205 mm
Depth54 mm
Weights
Weight, approx.260 g