General information
Product type designationF-DQ 4x 24 V DC/2 A PM HF
FW update possibleYes
usable BaseUnitsBU type A0
Color code for module-specific color-coded labelCC01
Product function
I&M dataYes; I&M0 to I&M3
Engineering with
STEP 7 TIA Portal configurable/integrated from versionV20 with HSP 470
STEP 7 configurable/integrated from versionas 6ES7136-6DB00-0CA0
PROFINET from GSD version/GSD revisionGSDML V2.45
CiR - Configuration in RUN
Reparameterization possible in RUNNo
Supply voltage
Rated value (DC)24 V
permissible range, lower limit (DC)19.2 V
permissible range, upper limit (DC)28.8 V
Reverse polarity protectionYes
power supply according to NEC Class 2 requiredNo
Input current
Current consumption (rated value)30 mA; without load
Current consumption, max.100 mA; without load
Output voltage
Rated value (DC)24 V
Power
Power consumption from the backplane bus70 mW
Power loss
Power loss, typ.3 W
Address space per module
Inputs6 byte; S7-300/400F CPU, 6 byte
Outputs6 byte; S7-300/400F CPU, 4 byte
Hardware configuration
Automatic encodingYes
Electronic coding element type FYes
Digital outputs
Type of digital outputTransistor
Number of digital outputs4
Digital outputs, parameterizableYes
output type acc. to IEC 61131, type 2Yes
Short-circuit protectionYes
Response threshold, typ.> 3.3 A
Open-circuit detectionYes
Response threshold, typ.8 mA
Overload protectionYes
Response threshold, typ.3 A
Limitation of inductive shutdown voltage tosourcing output: -39 V DC in relation to 2M, sinking output: +47 V DC in relation to 2M
Controlling a digital inputYes; digital output, according to IEC 61131-2, type 2
Switching capacity of the outputs
with resistive load, max.2 A
with inductive load, max.2 A
on lamp load, max.10 W
Load resistance range
lower limit12 Ω
upper limit2 000 Ω
Output voltage
for signal "1", min.24 V; L+ (-0.5 V)
Output current
for signal "1" rated value2 A
for signal "0" residual current, max.0.5 mA
Switching frequency
with resistive load, max.30 Hz; Symmetrical
with inductive load, max.0.1 Hz; according to IEC 60947-5-1, DC-13, symmetrical
with capacitive load, max.30 Hz; observe chapter "Switching of capacitive loads" in the manual
on lamp load, max.10 Hz; Symmetrical
Total current of the outputs
Current per channel, max.2 A; note derating data in the manual
Current per module, max.6 A; note derating data in the manual
Cable length
shielded, max.1 000 m
unshielded, max.500 m
Interrupts/diagnostics/status information
Diagnostics functionYes; See Chapter "Alarms/diagnostic messages" in the manual
Substitute values connectableNo
Alarms
Diagnostic alarmYes
Hardware interruptNo
Diagnostics indication LED
RUN LEDYes; green LED
ERROR LEDYes; red LED
Monitoring of the supply voltage (PWR-LED)Yes; green PWR LED
Channel status displayYes; green LED
for channel diagnosticsYes; red LED
for module diagnosticsYes; green/red DIAG LED
Potential separation channels
between the channelsNo
between the channels and backplane busYes
between the channels and the power supply of the electronicsNo
Isolation
Isolation tested with707 V DC (type test)
Standards, approvals, certificates
Siemens Eco Profile (SEP)Siemens EcoTech
Suitable for safety functionsYes
Ecological footprint
environmental product declarationYes; type II acc. to ISO 14021
Global warming potential
— global warming potential, (total) [CO2 eq]52 kg
— global warming potential, (during production) [CO2 eq]6.8 kg
— global warming potential, (during operation) [CO2 eq]45.8 kg
— global warming potential, (after end of life cycle) [CO2 eq]-0.628 kg
Highest safety class achievable in safety mode
Performance level according to ISO 13849-1PLe
Category according to ISO 13849-1Cat. 4
SIL acc. to IEC 61508SIL 3
Probability of failure (for service life of 20 years and repair time of 100 hours)
— Low demand mode: PFDavg in accordance with SIL2< 2.00E-04
— Low demand mode: PFDavg in accordance with SIL3< 2.00E-05
— High demand/continuous mode: PFH in accordance with SIL2< 1.00E-08 1/h
— High demand/continuous mode: PFH in accordance with SIL3< 1.00E-09 1/h
Ambient temperature during operation
horizontal installation, min.0 °C
horizontal installation, max.60 °C
vertical installation, min.0 °C
vertical installation, max.50 °C
Altitude during operation relating to sea level
Installation altitude above sea level, max.4 000 m; restrictions for installation altitudes > 2 000 m, see ET 200SP system manual
Dimensions
Width15 mm
Height73 mm
Depth58 mm
Weights
Weight, approx.30 g