General information
Product type designationAQ 4xI HART ISOL HA
Firmware versionV1.0
FW update possibleYes; The firmware update can take more than 5 minutes.
Usable terminal blocktype K0, L0, S0, R0 (see system manual for details)
Color code for module-specific color-coded labelCC40
Product function
I&M dataYes; I&M0 to I&M3
Engineering with
STEP 7 TIA Portal configurable/integrated from versionV17
STEP 7 configurable/integrated from versionV5.6
PCS 7 configurable/integrated from versionV9.1
PCS neo can be configured/integrated from versionV3.0
PROFINET from GSD version/GSD revisionGSDML V2.35
Redundancy
Redundancy capabilityYes; see the system manual
CiR - Configuration in RUN
Reparameterization possible in RUNYes
Supply voltage
Rated value (DC)24 V
permissible range, lower limit (DC)19.2 V
permissible range, upper limit (DC)28.8 V
Reverse polarity protectionYes
Input current
Current consumption (rated value)176 mA; At 4x 20 mA with 750 ohm load resistor
Current consumption, max.223 mA; at 4x 23.5 mA with 750 ohm load resistor
Power loss
Power loss, typ.3 W; At 4x 20 mA with 750 ohm load resistor
Address space per module
Address space per module, max.9 byte; 8 bytes for outputs and 1 byte for QI information
Address space per module with HART, max.29 byte; 8 bytes for outputs, 1 byte for QI information, 20 bytes for HART information
Address space per module with MultiHART, max.16 byte; 8 bytes for outputs, 1 byte for QI information, 6 bytes for HART information, 1 byte for HART command
Analog outputs
Number of analog outputs4
Current output, no-load voltage, max.22 V
Output ranges, current
0 to 20 mAYes; 15 bit
4 mA to 20 mAYes; 15 bit
Connection of actuators
for current output two-wire connectionYes
Load impedance (in rated range of output)
for current outputs, min.50 Ω
with current outputs, max.750 Ω
with current outputs, inductive load, max.10 mH
Destruction limits against externally applied voltages and currents
Voltages at the outputs24 V
Cable length
shielded, max.1 000 m; with unshielded cables up to 800 m, remember that (external) EMC loads can cause incorrect measured values
Settling time
for resistive load1.2 ms; 750 ohm
for inductive load1.2 ms
Errors/accuracies
Linearity error (relative to output range), (+/-)0.01 %
Temperature error (relative to output range), (+/-)0.002 %/K
Crosstalk between the outputs, min.70 dB
Repeat accuracy in steady state at 25 °C (relative to output range), (+/-)0.02 %
Operational error limit in overall temperature range
Current, relative to output range, (+/-)0.5 %; 0 ... 60 °C: 0.2 %
Basic error limit (operational limit at 25 °C)
Current, relative to output range, (+/-)0.1 %
Interrupts/diagnostics/status information
Diagnostics functionYes
Alarms
Diagnostic alarmYes
Diagnoses
Monitoring the supply voltageYes
Wire breakYes; channel by channel
Short-circuitYes
Overflow/UnderflowYes; channel by channel
Diagnostics indication LED
MAINT LEDYes; Yellow LED
Monitoring of the supply voltage (PWR-LED)Yes; green PWR LED
Channel status displayYes; green LED
for channel diagnosticsYes; red LED
for module diagnosticsYes; green/red DIAG LED
Potential separation channels
between the channelsYes; 125 V AC / 150 V DC (when using terminal blocks with push-in terminals); SELV/PELV (when using terminal blocks with D-SUB)
between the channels and backplane busYes; 125 V AC / 150 V DC (when using terminal blocks with push-in terminals); SELV/PELV (when using terminal blocks with D-SUB)
between the channels and the power supply of the electronicsYes; 125 V AC / 150 V DC (when using terminal blocks with push-in terminals); SELV/PELV (when using terminal blocks with D-SUB)
Permissible potential difference
between the channels125 V AC / 150 V DC (when using terminal blocks with push-in terminals); SELV/PELV (when using terminal blocks with D-SUB)
between the channels and supply voltage125 V AC / 150 V DC (when using terminal blocks with push-in terminals); SELV/PELV (when using terminal blocks with D-SUB)
between the channels and backplane bus125 V AC / 150 V DC (when using terminal blocks with push-in terminals); SELV/PELV (when using terminal blocks with D-SUB)
tested with
between backplane bus and load voltage3 000 V DC/1 min, type test
between the channels and load voltagebetween the channels 2 100 V DC/1 min, type test (when using terminal blocks with push-in terminals); 1 200 V DC/1 min, type test (when using terminal blocks with D-SUB)
between the channels and backplane bus3 000 V DC/1 min, type test
Between channelsbetween the channels 4 200 V DC/1 min, type test (when using terminal blocks with push-in terminals); 1 200 V DC/1 min, type test (when using terminal blocks with D-SUB)
Ambient temperature during operation
horizontal installation, min.-40 °C
horizontal installation, max.70 °C; Observe derating
vertical installation, min.-40 °C
vertical installation, max.60 °C; Observe derating
Dimensions
Width22.5 mm
Height115 mm
Depth138 mm
Weights
Weight, approx.165 g