General information
Product type designationIPC477E
Display
Design of display19" TFT touch
Screen diagonal18.5 in
Resolution (pixels)
Horizontal image resolution1 366 pixel
Vertical image resolution768 pixel
Backlighting
MTBF backlighting (at 25 °C)50 000 h
Input device
Mouse, at frontNo
Keyboard
Function keysNo
alphanumeric keyboardNo
Touch operation
Design as touch screenYes; analog, resistive
Installation type/mounting
MountingFor horizontal and vertical mounting
DesignPanel PC, built-in unit
central designYes
distributed designNo
Mounting in portrait format possibleYes
Supply voltage
Type of supply voltage100/240 V AC (autorange) 50/60 Hz; optional 24 V DC
Rated value (DC)24 V; PELV / SELV floating
Line frequency
Rated value 50 HzYes
Rated value 60 HzYes
Mains buffering
Mains/voltage failure stored energy time20 ms
Power loss
In full configuration24 V DC: max. 65 W, PCIe APCB additionally 5 W
Processor
Processor typeCeleron G3902 (2C/2T, 1.6 GHz, 2 MB Cache); Core i3-6102E (2C/4T, 1.9 GHz, 3 MB Cache); Core i5-6442EQ (4C/4T, 1.9 (2.7) GHz, 6 MB Cache, iAMT); Xeon E3-1505L v5 (4C/8T, 2.0 (2.8) GHz, 8 MB Cache, iAMT)
ChipsetIntel C236 / Intel H110
Graphic
Graphics controllerIntel HD graphics controller
Drives
Hard disk2.5" SATA ≥ 320 GB
SSDYes; 128 / 240 / 480 GB
Storage
Type of memoryDDR4-2400 SO-DIMM
Main memory4 / 8 / 16 GB, ECC optional
Capacity of main memory, max.16 Gbyte
Data areas and their retentivity
Retentive data area (incl. timers, counters, flags), max.512 kbyte; 128 KB can be stored in the buffer time; optional
Slots
Number of PCI slots1; Optional
Number of compact flash slots1; CFast
Interfaces
Number of industrial Ethernet interfaces3; 3x Ethernet (RJ45)
USB port4x USB 3.0
serial interfaceWithout / 2x COM (RS 232 / 422 / 485), selectable in the BIOS
Video interfaces
Graphics interface2x DisplayPort
Industrial Ethernet
Industrial Ethernet interface3x Ethernet (RJ45)
— 100 MbpsYes
— 1000 MbpsYes
Interrupts/diagnostics/status information
Bus diagnosticsYes
Monitoring functions
Temperature monitoringYes
WatchdogYes
FanNo
Monitoring function via networkOptional
Interference immunity against discharge of static electricity
Interference immunity against discharge of static electricity±6 kV contact discharge acc. to IEC 61000-4-2; ±8 kV air discharge acc. to IEC 61000-4-2
Interference immunity against high-frequency electromagnetic fields
Interference immunity against high frequency radiation10 V/m, 80 ... 2 000 MHz, 80 % AM acc. to IEC 61000-4-3; 3 V/m, 2 ... 2.7 GHz; 10 V, 10 kHz ... 80 MHz acc. to IEC 61000-4-6
Interference immunity to cable-borne interference
Interference immunity on supply cables±2 kV acc. to IEC 61000-4-4, burst; ±1 kV acc. to IEC 61000-4-5, surge symmetric; ±2 kV acc. to IEC 61000-4-5, surge asymmetric
Interference immunity on signal cables >30m±2 kV acc. to IEC 61000-4-5, surge, length > 30 m
Interference immunity on signal cables < 30m±1 kV acc. to IEC 61000-4-4; burst; length < 3 m; ±2 kV acc. to IEC 61000-4-4; burst; length > 3 m
Interference immunity against voltage surge
asymmetric interference±2 kV acc. to IEC 61000-4-5, surge asymmetric
symmetric interference±1 kV acc. to IEC 61000-4-5, surge symmetric
Interference immunity to magnetic fields
Interference immunity to magnetic fields at 50 Hz100 A/m; to IEC 61000-4-8
Emission of conducted and non-conducted interference
Interference emission via line/AC current cablesEN 61000-6-3, EN 61000-6-4, CISPR 22 Class B, FCC Class A
Degree and class of protection
IP (at the front)IP65
IP (rear)IP20
Standards, approvals, certificates
CE markYes
CSA approvalYes
UL approvalYes
UL 508Yes
cULusYes
RCM (formerly C-TICK)Yes
KC approvalYes
EAC (formerly Gost-R)Yes
FCCYes
EMCCE, EN 61000-6-4; CISPR 22:2004 Class A; FCC Class A
Use in hazardous areas
ATEX Zone 2Yes; for inscription on device rating plate
ATEX Zone 22Yes; for inscription on device rating plate
IECEx Zone 2Yes; for inscription on device rating plate
IECEx Zone 22Yes; for inscription on device rating plate
CCC ExYes; for inscription on device rating plate
cULus Class I Zone 1No
cULus Class I Zone 2, Division 2Yes; for inscription on device rating plate
cULus Class II Division 2Yes; for inscription on device rating plate
FM Class I Division 2No
FM Class II Division 2No
Marine approval
Germanischer Lloyd (GL)Yes
American Bureau of Shipping (ABS)Yes
Bureau Veritas (BV)Yes
Det Norske Veritas (DNV)Yes
Korean Register of Shipping (KRS)Yes
Lloyds Register of Shipping (LRS)Yes
Nippon Kaiji Kyokai (Class NK)Yes
Ambient temperature during operation
min.0 °C
max.45 °C
Ambient temperature during storage/transportation
min.-20 °C
max.60 °C
Relative humidity
Relative humidityTested according to IEC 60068-2-78, IEC 60068-2-30: 5% to 80% at 25 °C (no condensation)
Vibrations
Vibration resistance during operation acc. to IEC 60068-2-6IEC 60068-2-6; 5 Hz to 9 Hz: 3.5 mm; 9 Hz to 500 Hz: 9.8 m/s² (with SSD or CFast); 10 Hz to 58 Hz: 0.0375 mm; 58 Hz to 200 Hz: 4.9 m/s² (hard disk)
Shock testing
Shock load during operationIEC 60068-2-27; 150 m/s², 11 ms (without hard disk); 50 m/s², 30 ms (with hard disk)
Operating systems
pre-installed operating systemWindows 7 Ultimate (Multi-Language) 64-bit, Windows Embedded Standard 7 E/P 32-bit / 64-bit, Windows 10
without operating systemYes; Optional
pre-installed operating system
Windows 7Yes; Ultimate 64 bit
Windows 10 EnterpriseYes; Windows 10 Enterprise 2016 LTSB, 64 bit, MUI
Dimensions
Width of the housing front483 mm
Height of housing front337 mm
Mounting cutout, width465 mm
Mounting cutout, height319 mm
mounting depth76 mm
Weights
Weight, approx.8.4 kg