General information
Product type designationIPC227E
based on6ES7647-8BE72-7HA1
Installation type/mounting
MountingDIN rail, wall mounting, portrait mounting
DesignBox PC, built-in unit
Supply voltage
Type of supply voltage24 V DC
Mains buffering
Mains/voltage failure stored energy time20 ms
Processor
Processor typeIntel Atom E3845
ChipsetSoC
Graphic
Graphics controllerIntegrated
Graphics cardYes
Drives
SSDYes
Storage
Type of memoryDDR3L SO-DIMM
Capacity of main memory, max.4 Gbyte
Data areas and their retentivity
Retentive data area (incl. timers, counters, flags), max.512 kbyte; 128 KB can be stored in the buffer time; optional
Slots
Number of PCI slots0
Number of PCI slots1; Optional
Number of compact flash slots1; CFast
Interfaces
Number of industrial Ethernet interfaces2; 2x Ethernet (RJ45)
Number of PROFINET interfaces2
serial interfaceWithout / 2x COM (RS 232 / 422 / 485), selectable in the BIOS
Video interfaces
Graphics interface1x DisplayPort
Industrial Ethernet
— 100 MbpsYes
— 1000 MbpsYes
Interrupts/diagnostics/status information
LED status display1x power, 3x user
Monitoring functions
Temperature monitoringYes
FanNo
Monitoring function via networkOptional
Isolation
Isolation tested with750 V DC (type test) and according to EN 50155 (routine test)
Degree and class of protection
IP degree of protectionIP40
IP (rear)IP40
Railway application
EN 50121-3-2Yes; EMC for rail vehicles
EN 50121-4Yes; EMC for signal and telecommunications systems
EN 50124-1Yes; Railway applications - overvoltage category OV2; pollution degree PD2; rated surge voltage UNi = 0.5 kV; UNm = 24 V DC
EN 50125-1Yes; Rail vehicles - see ambient conditions
EN 50125-2Yes; Stationary electrical equipment - see ambient conditions
EN 50125-3Yes; Signal and telecommunications systems - see ambient conditions; vibrations and shocks: Application point outside of tracks (1 m to 3 m away from track)
EN 50155Yes; Rail vehicles - temperature class OT1, ST1/ST2, horizontal mounting position
EN 61373Yes; Rail vehicles - vibrations and shocks: Category 1 Class A/B
Fire protection acc. to EN 45545-2Yes; For proof of conformity, see Service & Support
Ambient temperature during operation
min.-25 °C; = Tmin (incl. condensation/frost)
max.60 °C; = Tmax; +70 °C for 10 min (OT1, ST1/ST2 acc. to EN 50155)
Ambient temperature during storage/transportation
min.-20 °C
max.60 °C
Altitude during operation relating to sea level
Installation altitude above sea level, max.2 000 m
Ambient air temperature-barometric pressure-altitudeTmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m)
Relative humidity
With condensation, tested in accordance with IEC 60068-2-38, max.100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation
Vibrations
Vibration resistance during operation acc. to IEC 60068-2-6tested to DIN IEC 60068-2-6: 10 Hz to 58 Hz: 0.075 mm, 58 Hz to 200 Hz: 9.8 m/s² (1 g)
Coolants and lubricants
— Resistant to commercially available coolants and lubricantsYes; Incl. diesel and oil droplets in the air
Use in stationary industrial systems
— to biologically active substances according to EN 60721-3-3Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request
— to chemically active substances according to EN 60721-3-3Available soon
— to mechanically active substances according to EN 60721-3-3Yes; Class 3S4 incl. sand, dust, *
Use on land craft, rail vehicles and special-purpose vehicles
— to biologically active substances according to EN 60721-3-5Yes; Class 5B2 mold, fungus and dry rot spores (with the exception of fauna); Class 5B3 on request
— to chemically active substances according to EN 60721-3-5in preparation
— to mechanically active substances according to EN 60721-3-5Yes; Class 5S3 incl. sand, dust; *
Usage in industrial process technology
— Against chemically active substances acc. to EN 60654-4in preparation
— Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04in preparation
Remark
— Note regarding classification of environmental conditions acc. to EN 60721, EN 60654-4 and ANSI/ISA-71.04* The supplied plug covers must remain in place over the unused interfaces during operation!
Conformal coating
Coatings for printed circuit board assemblies acc. to EN 61086Yes; Class 2 for high reliability
Protection against fouling acc. to EN 60664-3Yes; Type 1 protection
Electronic equipment on rolling stock acc. to EN 50155Yes; Class PC2 protective coating acc. to EN 50155:2017
Military testing according to MIL-I-46058C, Amendment 7Yes; Discoloration of coating possible during service life
Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830AYes; Conformal coating, Class A
Operating systems
pre-installed operating systemWindows 10 IoT Enterprise 2016 LTSB, 64bit, MUI
without operating systemYes; Optional
pre-installed operating system
Windows 7Yes; Ultimate 32 bit or 64 bit
Windows 10 EnterpriseYes; Windows 10 Enterprise 2016 LTSB, 64 bit, MUI
Dimensions
Width191 mm
Height100 mm
Depth60 mm
Other
Note:for use in railway applications, also observe the product information "SIPLUS extreme RAIL" A5E37661960A, Online Support article 109736776